DESIGN GUIDELINES FOR OUTSIDE COMBUSTION AIR CONNECTION
1)For installations with horizontal
2)Connection to outside the house is REQUIRED for mobile home installations.
90 DEGREE BEND TERMINATION | WIND HOOD TERMINATION |
Wind Hood
3” Min. Diameter
3”
2”
6”
3)Only noncombustible pipe 3 inches in diameter is approved to use for outside air connections (straight or flexible). PVC pipe is NOT approved and should NEVER be used.
4)If the air inlet is connected to the outside, it MUST be terminated with a vertical
5)Blockage, excessive length, or bends in the air intake pipe will starve the stove of combustion air. A
CAUTION: The operation of exhaust fans such as bath room fans, attic fans, etc. might starve the heater of combustible air creating a negative pressure in the room. Provide adequate ventilation in the room accompanying the heater.
8 | USSC |