QHT B3-B9 installation instructions Wiring

Page 23

11. Wiring

The electricity to the boiler shall come from a dedicated breaker in the electric service box. A service switch should be mounted on the side of the boiler so the burner technician can service the burner and controls. The electrical wiring should be routed so as not to interfere with normal servicing of the boiler. Wiring done in the field between devices not attached to boiler shall conform with the temperature limitations for type T wire (63F/35C) or other specified wire as applicable when installed in accordance to manufacturer's instructions and wiring diagrams.

If an external electrical source is utilized, the boiler, when installed, must be electrically bonded to ground in accordance with the requirements of the authority having jurisdiction or, in the absence of such requirements, with the National Electrical Code, ANSI/NFPA 70 and/or the Canadian Electrical Code Part 1, CSA C22.1, Electrical Code.

Since the boiler is equipped with a swinging burner door, the supplied 48” long burner wiring harness with 4-prong quick disconnect plug needs to be used. The short end of the wiring harness needs to be wired to the burner following the respective burner wiring diagram in the subsequent pages of this manual. The long end of the wiring harness needs to be wired into the burner service switch located at the installers discretion.

Refer to pages 19 to 23 for oil wiring diagrams and pages 24 to 25 for gas wiring diagrams.

Page 23

Image 23
Contents Phone FAX Manufactured by Biasi S.p.A Verona, Italy Distributed ByPage Table of Contents Please read this page carefully Important InformationPage To Start UP the Appliance Homeowner Information for GasGas systems only General InformationTrim Kit Components Do not Over Tighten Draw Rods Boiler Block AssemblyBoiler Location Switch Gas systems only Installation of Boiler Trim ComponentsBoiler Tapping Diagram Installation of Boiler Trim ComponentsPiping the Boiler Safety Relief ValveIntake Venting Figure a Common Exhaust Venting Exhaust VentingBlocked Flue Switch Gas Venting Gas Burner SetupOil Burner Manufacturer Oil Burner SetupGas Burner Setup Gas Line Piping Installation of Sediment Trap and Burner SupplyBoiler Jacket Assembly Wiring 7248U Wiring Procedure Oil Burner Wiring Riello OIL BURNER, SR504, Control Wiring with DHW Priority Riello OIL BURNER, AZ-4P, Control Wiring with DHW Priority Carlin OIL BURNER, SR501, Control Wiring with DHW Priority Page Heatwise SU-2A, SR503, Control Wiring with DHW Priority Page Commissioning MaintenanceSystem Checkout Installer NotesPage Page Tear on this Line

B3-B9 specifications

The QHT B3-B9 is a remarkable series of versatile vehicles designed to cater to a wide array of industries, including construction, mining, and heavy-duty logistics. With a focus on durability, efficiency, and innovative technology, the QHT B3-B9 stands out as a preferred choice for demanding tasks.

One of the key features of the QHT B3-B9 series is its robust frame construction, which employs high-strength steel to ensure maximum durability in harsh working conditions. This resilience allows the vehicle to withstand significant payloads while minimizing wear and tear, reducing maintenance costs over the long haul. Additionally, the design includes advanced corrosion resistance treatments, extending the vehicle's lifespan even in challenging environments.

The QHT B3-B9 is powered by a state-of-the-art engine, which adheres to the latest emissions standards while delivering impressive fuel efficiency. This engine utilizes advanced fuel injection technology, optimizing power output without compromising environmental responsibility. The combination of high torque and superior power-to-weight ratio enables the vehicle to perform effectively across various terrains, ensuring stability and control under load.

Another notable characteristic of the QHT B3-B9 series is its emphasis on operator comfort and safety. The cabin is ergonomically designed, featuring adjustable seating, intuitive controls, and enhanced visibility. This focus on user experience not only enhances productivity but also minimizes operator fatigue during long hours of operation. To further improve safety, the vehicle is equipped with comprehensive monitoring systems that provide real-time feedback on performance and potential issues.

Technologically, the QHT B3-B9 integrates advanced telematics, allowing operators and fleet managers to track performance metrics, fuel consumption, and maintenance schedules. This connectivity enables proactive management, reducing downtime and improving overall efficiency.

In conclusion, the QHT B3-B9 series represents a harmonious blend of strength, efficiency, and modern technology, making it an invaluable asset for businesses that require reliable performance in demanding environments. Its innovative features and commitment to operator safety and comfort ensure that it remains a top choice among heavy-duty vehicles in its class.