Troy-Bilt MXZ-3A30NA Before Installation, Following should Always be Observed for Safety

Page 2

1. BEFORE INSTALLATION

1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY

Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.

Be sure to observe the warnings and cautions specified here as they include important items related to safety.

After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS for future reference.

WARNING

(Could lead to death, serious injury, etc.)

nDo not install the unit by yourself (user).

Incomplete installation could cause fire or electric shock, injury due to the unit falling, or leakage of water. Consult the dealer from whom you pur- chased the unit or a qualified installer.

nPerform the installation securely referring to the installation manual.

Incomplete installation could cause fire or electric shock, injury due to the unit falling, or leakage of water.

nInstall the unit securely in a place which can bear the weight of the unit.

If the installation location cannot bear the weight of the unit, the unit could fall causing injury.

nPerform electrical work according to the installation manual and be sure to use an exclusive circuit. Do not connect other electrical appli- ances to the circuit.

If the capacity of the power circuit is insufficient or there is incomplete electrical work, it could result in a fire or an electric shock.

nDo not damage the wires by applying excessive pressure with parts or screws.

Damaged wires could cause fire.

nBe sure to cut off the main power in case of setting up the indoor P.C. board or wiring works.

Failure to do so could cause electric shock.

nUse the specified wires to connect the indoor and outdoor units se- curely and attach the wires firmly to the terminal block connecting sections so the stress of the wires is not applied to the sections.

Incomplete connecting and securing could cause fire.

nDo not install the unit in a place where inflammable gas may leak.

If gas leaks and accumulates in the area around the unit, it could cause an explosion.

nDo not use intermediate connection of the power cord or the exten- sion cord and do not connect many devices to one AC outlet.

It could cause a fire or an electric shock due to defective contact, defec- tive insulation, exceeding the permissible current, etc.

nBe sure to use the parts provided or specified parts for the installa- tion work.

The use of defective parts could cause an injury or leakage of water due to a fire, an electric shock, the unit falling, etc.

nWhen plugging the power supply plug into the outlet, make sure that there is no dust, clogging, or loose parts in both the outlet and the plug. Make sure that the power supply plug is pushed complete- ly into the outlet.

If there is dust, clogging, or loose parts on the power supply plug or the outlet, it could cause electric shock or fire. If loose parts are found on the power supply plug, replace it.

nAttach the electrical cover to the indoor unit and the service panel to the outdoor unit securely.

If the electrical cover of the indoor unit and/or the service panel of the outdoor unit are not attached securely, it could result in a fire or an electric shock due to dust, water, etc.

nWhen installing or relocating the unit, make sure that no sub- stance other than the specified refrigerant (R410A) enters the refrigerant circuit.

Any presence of foreign substance such as air can cause abnormal pressure rise or an explosion.

nDo not discharge the refrigerant into the atmosphere. If refrigerant leaks during installation, ventilate the room.

If refrigerant comes in contact with a fire, harmful gas could be gener- ated.

nCheck that the refrigerant gas does not leak after installation has been completed.

If refrigerant gas leaks indoors, and comes into contact with the flame of a fan heater, space heater, stove, etc., harmful substances will be generated.

nUse appropriate tools and piping materials for installation.

The pressure of R410A is 1.6 times more than R22. Not using appropri- ate tools or materials and incomplete installation could cause the pipes to burst or injury.

nWhen pumping down the refrigerant, stop the compressor before disconnecting the refrigerant pipes.

If the refrigerant pipes are disconnected while the compressor is run- ning and the stop valve is open, air could be drawn in and the pressure in the refrigeration cycle could become abnormally high. This could cause the pipes to burst or injury.

nWhen installing the unit, securely connect the refrigerant pipes before starting the compressor.

If the compressor is started before the refrigerant pipes are connected and when the stop valve is open, air could be drawn in and the pres- sure in the refrigeration cycle could become abnormally high. This could cause the pipes to burst or injury.

nFasten a flare nut with a torque wrench as specified in this manual.

If fastened too tight, a flare nut may break after a long period and cause refrigerant leakage.

nThe unit shall be installed in accordance with national wiring regu- lations.

nGround the unit correctly.

Do not connect the ground to a gas pipe, water pipe, lightning rod or telephone ground. Defective grounding could cause electric shock.

CAUTION

(Could lead to serious injury in particular environments when operated incorrectly.)

nInstall an ground leakage breaker depending on the installation place.

If an ground leakage breaker is not installed, it could cause electric shock.

nPerform the drainage/piping work securely according to the installa- tion manual.

If there is defect in the drainage/piping work, water could drop from the unit, soaking and damaging household goods.

1-2. REQUIRED TOOLS FOR INSTALLATION

nDo not touch the air inlet or the aluminum fins of the outdoor unit.

This could cause injury.

nDo not install the outdoor unit where small animals may live.

If small animals enter and touch the electric parts inside the unit, it could cause a malfunction, smoke emission, or fire. Also, advise user to keep the area around the unit clean.

Phillips screwdriver

Torque wrench

Gauge manifold for R410A

Level

Wrench (or spanner)

Vacuum pump for R410A

Scale

4 mm (5/32 in.) hexagonal wrench

Charge hose for R410A

Utility knife or scissors

Flare tool for R410A

Pipe cutter with reamer

1-3. SPECIFICATIONS

Model

Power supply

 

Pipe length and height difference *2, *3, *4, *8

 

Rated

Frequency

Max. pipe length per indoor

Max.

Max. no. of bends per in-

Refrigerant adjustment A

 

Voltage

unit / for multi-system

height difference

door unit / for multi system

*5

MXZ-3A30NA

208/

60 Hz

25 m (82 ft) / 70 m (230 ft)

15 m (49 ft)

25 / 70

20 g/m (1.06 oz each 5 ft)

MXZ-4A36NA

230 V

 

 

 

 

 

*1 Never use pipes with thickness less than specified. The pressure resist- ance will be insufficient.

*2 Use a copper pipe or a copper-alloy seamless pipe.

*3 Be careful not to crush or bend the pipe during pipe bending.

*4 Refrigerant pipe bending radius must be 100 mm (4 in.) or more.

*5 If pipe length exceeds 40 m (131 ft), additional refrigerant (R410A) charge is required. (No additional charge is required for pipe length less than 40 m (131 ft).)

Additional refrigerant (m) = A × (pipe length (m) - 40)

Additional refrigerant (ft) = A × (pipe length (ft) - 131)

5

*6 Insulation material : Heat resisting foam plastic 0.045 specific gravity

*7 Be sure to use the insulation of specified thickness. Excessive thickness may cause incorrect installation of the indoor unit and insufficient thick- ness may cause dew drippage.

*8 If the outdoor unit is installed higher than the indoor unit, max. height difference is reduced to 10 m (33 ft).

Image 2
Contents Installation Manual Required Tools for Installation Before InstallationFollowing should Always be Observed for Safety SpecificationsFree Space Required around Outdoor Unit Selecting the Installation LocationSelecting Pipe Size and Optional DIFFERENT-DIAMETER Joints Parts to be Provided AT Your Site Installation DiagramOutdoor unit installation Connecting Wires for Outdoor Unit Outdoor Unit InstallationInstalling the Unit Connecting Wires and Connecting Ground Wire Disconnect switch may be required. Check the local codeConnect wires to the matching numbers of terminals Power Supply Cable and Ground WirePipe Connection Flaring Work and Pipe ConnectionFlaring Work Insulation and TapingGAS Charge Purging PROCEDURES, Leak TEST, and Test RUNPurging Procedures and Leak Test Test RUN Explanation to the UserPage Manual DE Instalación El usuario no debe instalar la unidad Antes DE LA InstalaciónEspecificaciones Nota Selección DEL Lugar DE InstalaciónEspacio Libre Necesario EN Torno a LA Unidad Exterior Instalación de la unidad exterior Diagrama DE InstalaciónComponentes QUE Deberá Adquirir LO- Calmente Cables DE Conexión Para LA Unidad Exterior Instalación DE LA Unidad ExteriorInstalación DE LA Unidad 4A36NACable DE Alimentación Y Cable DE Tierra Conexión DE Cables Y Conexión DEL Cable DE TierraSiga la normativa eléctrica local AtenciónConexión DE Tuberías Trabajos DE Abocardado Y Conexión DE TuberíasTareas DE Abocardamiento Aislamiento Térmico Y Forrado CON CintaCarga DE GAS CuidadoAcerca del mecanismo de protección de la reanudación Comprobación DE FuncionamientoExplicación Para EL Usuario Función de corrección de conexiones/tuberíasJG79A073H01

MXZ-4A36NA, MXZ-3A30NA specifications

Troy-Bilt has long been a trusted name in outdoor power equipment, and their latest offerings, the MXZ-4A36NA and MXZ-3A30NA, exemplify the brand's commitment to quality and innovation in the field of lawn maintenance. Designed for homeowners and landscapers alike, these lawn mowers provide exceptional performance and versatility for tackling various mowing tasks.

The MXZ-4A36NA model boasts a powerful 24 HP engine, allowing it to effortlessly cut through thick grass and navigate uneven terrain. Its standout feature is the 36-inch cutting deck, which is not only robust but also designed to provide a clean and precise cut. An adjustable cutting height ensures that users can achieve their desired lawn finish, whether it's a smooth, manicured look or a slightly longer finish for a healthier lawn.

Similarly, the MXZ-3A30NA model provides efficiency with its 21 HP engine and 30-inch cutting deck. This smaller size makes it ideal for those with smaller lawns or more intricate landscaping. The compact design doesn’t skimp on power or performance; it ensures maneuverability in tight spaces, making it suitable for various properties.

Both models feature advanced technology that enhances the mowing experience. Troy-Bilt's "TractorTuff" technology allows for an easy start-up and smooth operation, while the 'Smart Switch' ignition system adds convenience with simple push-button starts. These features not only make operating the mowers easier but also increase overall reliability.

In terms of user comfort, the MXZ series includes features such as an ergonomic seat and easy-to-reach controls, making extended mowing sessions more enjoyable. The mowers are designed with durability in mind as well, featuring heavy-duty construction and high-quality materials to withstand the rigors of regular use.

Another noteworthy characteristic is the maintenance-friendly design. Both models come with quick-access panels, making it easier for users to perform regular maintenance tasks like oil changes and blade replacements without hassle.

Overall, the Troy-Bilt MXZ-4A36NA and MXZ-3A30NA represent an impressive combination of power, efficiency, and user-friendly features. Whether for professional landscaping or residential use, these mowers are equipped to handle a wide range of mowing challenges effectively and with ease, making them worthy additions to any lawn care arsenal.