Troy-Bilt MXZ-3A30NA, MXZ-4A36NA Installation Diagram, Parts to be Provided AT Your Site

Page 4

1-6. INSTALLATION DIAGRAM

 

Open as a rule

 

More than 500 mm

 

(19.69 in.) if the front

MXZ-3A30NA

and both sides are open

 

More than 100 mm (3.94 in.)

After the leak test, apply insulat- ing material tightly so that there is no gap.

When the piping is to be at- tached to a wall containing metals (tin plated) or metal netting, use a chemically treated wooden piece 20 mm (7.9 in.) or thicker between the wall and the piping or wrap 7 to 8 turns of insulation vinyl tape around the piping.

To use existing piping, perform COOL operation for 30 minutes and pump down before removing the old air conditioner. Remake flare according to the dimension for new refrigerant.

More than

100 mm (3.94 in.) More than

200 mm (7.87 in.) if there are obstacles to both sides

PARTS TO BE PROVIDED AT YOUR SITE

(A)

Power supply cord*

1

(B)

Indoor/outdoor unit connecting wire*

1

(C)

Extension pipe (Refer to 1-4.)

1

(D)

Wall hole cover

1

(E)

Piping tape

1

 

Extension drain hose

 

(F)

(or soft PVC hose, 15 mm (19/32 in.)

1

 

inner dia. or hard PVC pipe VP16)

 

(G)

Refrigeration oil

Little

amount

 

 

(H)

Putty

1

(I)

Pipe fixing band

2 to 7

(J)

Fixing screw for (I)

2 to 7

(K)

Wall hole sleeve

1

(L)

Soft PVC hose, 25 mm (31/32 in.)

1

 

inner dia. or hard PVC pipe VP25

 

* Note:

Place indoor/outdoor unit connecting wire (B) and power supply cord (A) at least 1 m (39.4 in.) away from the TV antenna wire.

The “Q’ty” for (B) to (K) in the above table is quan- tity to be used per indoor unit.

Open as a rule

More than 500 mm (19.69 in.) if the back, both sides and top are open

More than 350 mm (13.78 in.)

Units should be installed by licensed contractor according to local code requirements.

Outdoor unit installation

 

2-U-shape notched holes

 

(Base bolt M10)

Air in

 

Air in

 

Air out

2-12 (0.47) 36 (1.42) Oval holes

 

(Base bolt M10)

[Unit: mm (inch)]

Image 4
Contents Installation Manual Before Installation Following should Always be Observed for SafetyRequired Tools for Installation SpecificationsSelecting Pipe Size and Optional DIFFERENT-DIAMETER Joints Selecting the Installation LocationFree Space Required around Outdoor Unit Outdoor unit installation Installation DiagramParts to be Provided AT Your Site Installing the Unit Outdoor Unit InstallationConnecting Wires for Outdoor Unit Disconnect switch may be required. Check the local code Connect wires to the matching numbers of terminalsConnecting Wires and Connecting Ground Wire Power Supply Cable and Ground WireFlaring Work and Pipe Connection Flaring WorkPipe Connection Insulation and TapingPurging Procedures and Leak Test Purging PROCEDURES, Leak TEST, and Test RUNGAS Charge Test RUN Explanation to the UserPage Manual DE Instalación Especificaciones Antes DE LA InstalaciónEl usuario no debe instalar la unidad Espacio Libre Necesario EN Torno a LA Unidad Exterior Selección DEL Lugar DE InstalaciónNota Componentes QUE Deberá Adquirir LO- Calmente Diagrama DE InstalaciónInstalación de la unidad exterior Instalación DE LA Unidad Exterior Instalación DE LA UnidadCables DE Conexión Para LA Unidad Exterior 4A36NAConexión DE Cables Y Conexión DEL Cable DE Tierra Siga la normativa eléctrica localCable DE Alimentación Y Cable DE Tierra AtenciónTrabajos DE Abocardado Y Conexión DE Tuberías Tareas DE AbocardamientoConexión DE Tuberías Aislamiento Térmico Y Forrado CON CintaCarga DE GAS CuidadoComprobación DE Funcionamiento Explicación Para EL UsuarioAcerca del mecanismo de protección de la reanudación Función de corrección de conexiones/tuberíasJG79A073H01

MXZ-4A36NA, MXZ-3A30NA specifications

Troy-Bilt has long been a trusted name in outdoor power equipment, and their latest offerings, the MXZ-4A36NA and MXZ-3A30NA, exemplify the brand's commitment to quality and innovation in the field of lawn maintenance. Designed for homeowners and landscapers alike, these lawn mowers provide exceptional performance and versatility for tackling various mowing tasks.

The MXZ-4A36NA model boasts a powerful 24 HP engine, allowing it to effortlessly cut through thick grass and navigate uneven terrain. Its standout feature is the 36-inch cutting deck, which is not only robust but also designed to provide a clean and precise cut. An adjustable cutting height ensures that users can achieve their desired lawn finish, whether it's a smooth, manicured look or a slightly longer finish for a healthier lawn.

Similarly, the MXZ-3A30NA model provides efficiency with its 21 HP engine and 30-inch cutting deck. This smaller size makes it ideal for those with smaller lawns or more intricate landscaping. The compact design doesn’t skimp on power or performance; it ensures maneuverability in tight spaces, making it suitable for various properties.

Both models feature advanced technology that enhances the mowing experience. Troy-Bilt's "TractorTuff" technology allows for an easy start-up and smooth operation, while the 'Smart Switch' ignition system adds convenience with simple push-button starts. These features not only make operating the mowers easier but also increase overall reliability.

In terms of user comfort, the MXZ series includes features such as an ergonomic seat and easy-to-reach controls, making extended mowing sessions more enjoyable. The mowers are designed with durability in mind as well, featuring heavy-duty construction and high-quality materials to withstand the rigors of regular use.

Another noteworthy characteristic is the maintenance-friendly design. Both models come with quick-access panels, making it easier for users to perform regular maintenance tasks like oil changes and blade replacements without hassle.

Overall, the Troy-Bilt MXZ-4A36NA and MXZ-3A30NA represent an impressive combination of power, efficiency, and user-friendly features. Whether for professional landscaping or residential use, these mowers are equipped to handle a wide range of mowing challenges effectively and with ease, making them worthy additions to any lawn care arsenal.