1 Introduction
|
| Table | |
|
|
|
|
Label | Color |
| Description |
Port | On/Flashing Amber |
| Port has a valid link at 10 or 100 Mbps. Flashing indicates activity. |
(Link/Activity/ |
|
|
|
On/Flashing Green |
| Port has a valid link at 1000 Mbps. Flashing indicates activity. | |
Speed Mode) |
| ||
|
|
| |
Off |
| There is no valid link on the port. | |
|
| ||
|
|
|
|
Port | On Amber |
| A PoE device is connected. |
(PoE Mode) |
|
|
|
Off |
| No PoE device connected. | |
|
| ||
|
|
|
|
Port 21/22/23/ | On Green |
| SFP transceiver plugged in. |
24 |
|
|
|
Off |
| No SFP transceiver plugged in. | |
|
| ||
|
|
|
|
Port 25/26 | On/Flashing Amber |
| Port has a valid link at 10 or 100 Mbps. Flashing indicates activity. |
|
|
|
|
| On/Flashing Green |
| Port has a valid link at 1000 Mbps. Flashing indicates activity. |
|
|
|
|
| Off |
| There is no valid link on the port. |
|
|
|
|
|
|
| System LEDs |
|
|
| Figure |
|
| Table | |
|
|
|
|
LED | Condition |
| Status |
|
|
|
|
Power | On Green |
| Internal power is operating normally. |
|
|
|
|
| On Amber |
| Internal Power supply fault. |
|
|
|
|
| Flashing Amber |
| RPU failure. |
|
|
|
|
| Off |
| Power off or failure. |
|
|
|
|
Diag | Flashing Amber |
| System diagnostic fail. |
|
|
|
|
| On Green |
| System diagnostic test OK. |
|
|
|
|
| On Amber |
| System diagnostic in progress. |
|
|
| |
| Alternate Amber- | Blink amber & green while booting. | |
| Green |
|
|
PoE Status | On Green |
| Port LEDs display each port’s PoE Status |
|
|
|
|
| Flashing Green |
| The switch has reached or exceeded 95% of its power budget. |
|
|
|
|
| Amber |
| Indicates a thermal shutdown for the whole system. |
|
|
|
|
| Flashing Amber |
| Indicates a high temperature warning. |
|
|
|
|