Smith Cast Iron Boilers GS110W operation manual Boiler Ratings & Capacities, Boiler Location

Page 3

GS110 DIRECT VENT BOILER INSTALLATION AND OPERATION INSTRUCTIONS

Page 3

The installation must conform to the requirements of the authority having jurisdiction or, in the absence of such requirements, to the National Fuel Gas Code, ANSI Z223.1-latest revision. In Canada, the installation must be in accordance with the requirements of CSA B149.1 or B149.2 Installation Code for Gas Burning Appliances and Equipment.

BOILER RATINGS & CAPACITIES

Before undertaking the installation of the GS110 check the boiler rating plate to ensure that the boiler is the proper size for the job. The "Net I=B=R Ratings" specify the equivalent amount of direct cast iron radiation that the boiler can handle under normal conditions.

Also ensure that the boiler has been set up for the type of gas available at the installation site. Other important considerations are the availability of an adequate electrical supply, fresh air for combustion and proximity a suitable outside wall.

BOILER LOCATION

WARNING: The clearances to combustible construction show in Figure 1 must be main- tained. Failure to comply with this warning can result in extensive property damage, severe personal injury or death!

CAUTION: Do not lift the boiler by the jacket. Use a hand truck under the base frame as shown in Figure 2.

1.Locate the boiler in an area that provides good access to the unit. Keep in mind that servicing may require the removal of jacket panels. Accessibility clearances must take precedence over fire protection clearances.

Figure 1 - Clearances to Combustible Construction

2.An optimum site will be level, central to the hot water piping system, close to an outside wall and have adequate fresh air for combustion.

3.Ensure that the floor is structurally sound and will support the weight of the boiler.

NOTE: This boiler is designed for direct placement on a combustible floor. Never install this boiler on carpeting!

4.DO NOT install this boiler in a location that would subject any of the gas ignition components to direct contact with water or excessive moisture during operation or servicing.

5.NEVER store objects on or around the boiler.

WARNING: Never store combustible materials, gasoline or any product containing flammable vapors or liquids in the vicinity of the boiler. Failure to comply with this warning can result in extensive property damage, severe personal injury or death!

Figure 2 - Moving Boiler

Image 3
Contents GS110W Before YOU Start ContentsBoiler Location Boiler Ratings & CapacitiesAll Combustion Air From Inside The Building Combustion AIR & VentilationDuct Size Combustion Air Duct SizingNumber Combustion Air System SizingIntake Air Optional Horizontal Guidelines Intake Air Option Vertical GuidelinesSmith Page Horizontal Direct Vent Systems General Venting GuidelinesGeneral Direct Vent Info Vent System OptionsCertified Vent Terminals Vertical Direct Vent SystemsHorizontal Vent Positive Pressure Systems Certified Vent & Intake TerminalsEquivalent Breeching & Chimney Size Vertical Vent Positive Pressure SystemsVertical Vent Negative Pressure Systems Chimney Inspection & SizingVertical Positive Pressure Venting Cat Common Vent Systems Boiler Water Volume Condensate PipingHeating System Piping Bypass Piping System BypassPump Away Bypass Circulators Piping For Use With Cooling UnitsGas Pipe Capacity Equivalent Pipe Length ChartWhen servicing controls. Wiring errors can cause GAS Supply PipingThermostat Installation Operational SequenceControl Outputs Wiring Connection Diagram Wiring Ladder Diagram For Your Safety Read Before Operating Pour Votre Sécurité Lisez Avant DE Mettre EN Marche Boiler SET UP Boiler OperationDirect Ignition System Air and Manifold Pressure Boiler Checking & AdjustmentBoiler Maintenance Instructions to the Installer Page Model Size with Item Quantities Below Ref # Name of Part Service and Replacement Parts ListModel Size with Item Quantities Below Page North ELM Street WESTFIELD, MA 01085 TEL 562-9631 FAX 413

GS110W specifications

The Smith Cast Iron Boilers GS110W stands as a premier choice for those seeking efficiency and reliability in heating systems. Known for their robust construction and advanced engineering, Smith Boilers are designed to meet the needs of both residential and commercial applications. The GS110W model showcases an impressive blend of performance and durability, making it a favorite among HVAC professionals and end users alike.

One of the main features of the GS110W is its cast iron construction. Cast iron is celebrated for its ability to retain heat, allowing the boiler to operate efficiently while providing consistent warmth over extended periods. This material also contributes to the boiler's longevity, allowing it to withstand the rigors of heating without significant wear and tear. The GS110W is designed to last, making it a wise investment for any heating needs.

The GS110W boasts an output capacity of 110,000 BTU/hour, making it suitable for a variety of heating applications. This output enables it to efficiently heat large spaces, whether in a multi-story building or a spacious home. The boiler’s efficiency rating is further enhanced by its ability to use multi-fuel options. It can efficiently burn oil or gas, providing flexibility depending on the availability and cost of fuel.

In terms of technology, the GS110W incorporates advanced boiler design that includes a submerged combustion chamber. This engineering feature allows for superior heat transfer while minimizing heat loss, ensuring that the maximum amount of energy is utilized for heating. Additionally, the boiler features a low water cutoff to enhance safety, preventing potential overheating and system failures.

Reliability is further ensured through the GS110W’s built-in controls and adjustments. The boiler is equipped with a digital aquastat that allows for precise temperature management, ensuring optimal performance. This user-friendly feature makes it easier for homeowners and technicians to monitor system conditions and make necessary adjustments for peak efficiency.

Another noteworthy characteristic of the Smith Cast Iron Boilers GS110W is its low emissions output. As environmental considerations become increasingly important, the GS110W is designed to minimize its environmental impact while still delivering powerful heating capabilities.

In conclusion, the Smith Cast Iron Boilers GS110W offers an outstanding combination of durability, efficiency, and advanced technology. Its robust cast iron construction, multi-fuel capability, and innovative design features make it a top choice for anyone looking to enhance their heating system. For those in search of reliable and efficient heating solutions, the GS110W stands out as a formidable contender.