Smith Cast Iron Boilers GS110W operation manual Intake Air Option Vertical Guidelines

Page 7

GS110 DIRECT VENT BOILER INSTALLATION AND OPERATION INSTRUCTIONS

Page 7

All joints in metal intake air systems must be secured using corrosion resistant fasteners and sealed using a suitable Silicone caulk. If PVC or CPVC is used, the joints must be cleaned with a suitable solvent and connected using a solvent based PVC cement. The intake air system MUST be supported by the building structure not the boiler/water heater.

Intake Air Option - Vertical Guidelines

A listed, nonrestrictive intake air cap must be used. The intake air cap must terminate as shown in Figure 6. The penetration point in the roof must be properly flashed and sealed.

Intake Air Optional - Horizontal Guidelines

The maximum equivalent length for the horizontal intake air pipe is listed in Table 2. The intake air system must be pitched down, toward the terminal, 1/4" per foot (21 mm per meter).

If horizontal runs exceed 5 feet (1.5 m) they must be supported at 3 foot (0.98 m) intervals with overhead hangers. Figures 7 through 10 show the four horizontal air intake options. The intake terminations certified for use the GS110 are listed in Table 5.

Figure 6 - Vertical Positive Pressure Venting with Outdoor Combustion Air (Cat. III)

Image 7
Contents GS110W Before YOU Start ContentsBoiler Location Boiler Ratings & CapacitiesAll Combustion Air From Inside The Building Combustion AIR & VentilationDuct Size Combustion Air Duct SizingNumber Combustion Air System SizingIntake Air Optional Horizontal Guidelines Intake Air Option Vertical GuidelinesSmith Page Horizontal Direct Vent Systems General Venting GuidelinesGeneral Direct Vent Info Vent System OptionsCertified Vent Terminals Vertical Direct Vent SystemsHorizontal Vent Positive Pressure Systems Certified Vent & Intake TerminalsEquivalent Breeching & Chimney Size Vertical Vent Positive Pressure SystemsVertical Vent Negative Pressure Systems Chimney Inspection & SizingVertical Positive Pressure Venting Cat Common Vent Systems Condensate Piping Boiler Water VolumeHeating System Piping System Bypass Bypass PipingPump Away Bypass Circulators Piping For Use With Cooling UnitsGas Pipe Capacity Equivalent Pipe Length ChartWhen servicing controls. Wiring errors can cause GAS Supply PipingOperational Sequence Thermostat InstallationControl Outputs Wiring Connection Diagram Wiring Ladder Diagram For Your Safety Read Before Operating Pour Votre Sécurité Lisez Avant DE Mettre EN Marche Boiler Operation Boiler SET UPDirect Ignition System Air and Manifold Pressure Boiler Checking & AdjustmentBoiler Maintenance Instructions to the Installer Page Model Size with Item Quantities Below Ref # Name of Part Service and Replacement Parts ListModel Size with Item Quantities Below Page North ELM Street WESTFIELD, MA 01085 TEL 562-9631 FAX 413

GS110W specifications

The Smith Cast Iron Boilers GS110W stands as a premier choice for those seeking efficiency and reliability in heating systems. Known for their robust construction and advanced engineering, Smith Boilers are designed to meet the needs of both residential and commercial applications. The GS110W model showcases an impressive blend of performance and durability, making it a favorite among HVAC professionals and end users alike.

One of the main features of the GS110W is its cast iron construction. Cast iron is celebrated for its ability to retain heat, allowing the boiler to operate efficiently while providing consistent warmth over extended periods. This material also contributes to the boiler's longevity, allowing it to withstand the rigors of heating without significant wear and tear. The GS110W is designed to last, making it a wise investment for any heating needs.

The GS110W boasts an output capacity of 110,000 BTU/hour, making it suitable for a variety of heating applications. This output enables it to efficiently heat large spaces, whether in a multi-story building or a spacious home. The boiler’s efficiency rating is further enhanced by its ability to use multi-fuel options. It can efficiently burn oil or gas, providing flexibility depending on the availability and cost of fuel.

In terms of technology, the GS110W incorporates advanced boiler design that includes a submerged combustion chamber. This engineering feature allows for superior heat transfer while minimizing heat loss, ensuring that the maximum amount of energy is utilized for heating. Additionally, the boiler features a low water cutoff to enhance safety, preventing potential overheating and system failures.

Reliability is further ensured through the GS110W’s built-in controls and adjustments. The boiler is equipped with a digital aquastat that allows for precise temperature management, ensuring optimal performance. This user-friendly feature makes it easier for homeowners and technicians to monitor system conditions and make necessary adjustments for peak efficiency.

Another noteworthy characteristic of the Smith Cast Iron Boilers GS110W is its low emissions output. As environmental considerations become increasingly important, the GS110W is designed to minimize its environmental impact while still delivering powerful heating capabilities.

In conclusion, the Smith Cast Iron Boilers GS110W offers an outstanding combination of durability, efficiency, and advanced technology. Its robust cast iron construction, multi-fuel capability, and innovative design features make it a top choice for anyone looking to enhance their heating system. For those in search of reliable and efficient heating solutions, the GS110W stands out as a formidable contender.