INSTALLATION

The Manifold Unit

Determine the most practical under-the-sink location for placement of the Sierra manifold unit and the companion reservoir tank. Ensure that the specific location allows adequate access to the manifold unit for cartridge replacement and to the tank for tank- valve operation.

1.Place the manifold and tank in the selected locations. If desired, the #6 self tapping screws may be used to secure the manifold unit in position by means of the top rear and bottom lip mounting holes.

2.Take the unused portion of the 3/8" white tubing and insert one end firmly into the 3/8" (larg- est) connector on the top of the manifold unit.

3.Extend the 3/8" white tubing from the manifold unit to the tank valve. Leave enough slack in the tubing to allow the unit to be removed from the installed location for servicing. Cut off the excess and insert the 3/8" tube into the quick-connect tank valve fitting until it is fully engaged.

4.Extend the 1/4" yellow tubing from the faucet unit to the manifold. Leave enough slack in the tubing to allow the unit to be removed from the installed location for servicing. Cut off the excess and firmly insert the tubing into the corresponding yellow drain connection located on the mani- fold.

5.Extend the 3/8" blue tubing from the faucet unit to the manifold. Leave enough slack in the tubing to allow the unit to be removed from the installed location for servicing. Cut off the excess and firmly insert the tubing into the corresponding blue product water connection located on the manifold.

6.Extend the green tubing from the feed connector valve to the manifold. Leave enough slack in the tubing to allow the unit to be removed from the installed location for servicing. Cut off the excess and firmly insert the tubing into the corresponding green feed connection located on the manifold.

7.Obtain the Shutoff Warning label and affix it to the manifold unit so that it is directly visible. The Sierra system is now connected and ready for initial test and preparation.

TUBING HINTS: Use a sharp knife or tubing cutter to cut the

 

tubing squarely, being sure to remove all burrs. Then insert the

 

tubing firmly until it stops. To remove the tubing, push against

 

the collet while pulling on the tubing.

Fig 7

Fig 8

Fig 9

Fig 10

13

Image 13
Contents Installation Guide M p o n e n t Interval Indications For Service Maintenance ScheduleDescription ReplacementsMisc System Performance Feed Water Requirements Arsenic Facts SystemInformation SystemWarrantyBeforeYouBegin InstallationSierra Manifold Unit PartsParts Kit not Shown Faucet Kit Not ShownConnec- t o r FeedConnectionDrillingTheSink DrainConnectionFormica or Wooden Counter Tile Sink or Counter Enamel, Porcelain-Over-Steel, or Cast Iron SinkStainless Steel Sink PushHandleFaucet Manifold Unit Activation/Flushing InitialFlushingProcedureSystemActivation andInspection CheckList Cartridges/Tank CartridgeReplacementTankSanitizing Nimbus Water Systems 2007 PN103257