3
INSTALLATION
FeedConnection
1.Locate and turn off the angle stop valve on the cold water line feeding the sink where the Sierra unit is to be installed. This valve will usually be located under the sink on the pipe coming out of the wall.
Hint: Be sure to make this connection on the COLD water feed, not the HOT water feed. If you are not sure which line is the cold water line, open the hot water tap on the sink until hot water flows from the faucet. The hot water line under the sink can then be identified by touch.
2.When the angle stop valve is closed, relieve pressure in the line by opening the cold water tap on the sink.
3.It may be possible to install the feed adapter fitting at either the angle stop valve or at the faucet inlet connector depending on the size and type of fittings at your location. The angle stop valve is preferable because of its easier accessibility. Both options are given in Fig 1.
Option A - To install the feed adapter at the faucet connector disconnect the cold water feed line where it connects to the faucet inlet connector. This will usually require an open end wrench, pliers, or long reach faucet wrench. Proceed to step 4.
Option B - To install the feed adapter at the angle stop valve, disconnect the feed line at the angle stop valve. This will usually require a wrench or pliers. With this end of the water line free, proceed to step 4.
Options
A B
Rubber
Washer
Valve
Angle
Stop
Valve
Std. Feed
Fig.1 Connec- t o r
4.Take the 1/4" feed connector valve from the parts kit and install it into the brass feed connector adapter. Use a crescent wrench or
5.Using the flat and cone washers as necessary, install the feed adapter into the faucet inlet connector or angle stop valve as chosen above. Then reconnect the cold water feed line to the open end of the feed adapter. Tighten all con-
nections securely.
COMPRESSION NUT
6. Using the green 1/4" tubing, install the com- |
|
| INSERT | |
pression nut, plastic ferrule, and plastic tube |
|
| ||
TUBING |
|
| ||
insert. Secure the tubing into the feed connec- | FERRULE | Fig. 2 | ||
| ||||
tor valve. Tighten the tubing retaining nut se- |
|
|
| |
|
|
| ||
curely. See Fig.2. |
|
|
|
7.Obtain the small feed valve warning tag from the parts bag and attach it by its wire ties to the feed valve.
9