9

INSTALLATION

CheckList

1.Sierra unit and tank are located where they will not be subject to physical impacts or rough contact by heavy objects.

2.Feed water pressure to the unit is no less than 40 psi and no greater than 80 PSI.

3.Ensure the plastic retainer clips are fully engaged. The slide locks must snap into place in the slots. If the clip does not snap easily into place through the slots it means the cartridge is not fully inserted into the connectors. Press top or bottom of cartridge to engage connectors until it snaps into place properly.

4.All tubing connections, especially push-in quick connections, are fully inserted.

5.Tubing connected between the faucet and the drain saddle fitting (the fitting attached to the sink drain pipe) runs "downhill" to the drain. There should be no loops or places where water would not flow out to the drain.

6.Feed and tank valves are open.

7.Within one to two hours after initial application of water pressure, check again for leaks especially at the tank, faucet tubing and connectors. These parts will not see full pressure until approximately

2hours after the system is activated.

8.Flush three tankfuls of product water to drain. If a chlorine scent persists, repeat flushing procedure in Section 8.

15

Image 15
Contents Installation Guide M p o n e n t Interval Indications For Service Maintenance ScheduleReplacements DescriptionMisc System Performance Feed Water Requirements Arsenic Facts SystemInformation SystemWarrantyBeforeYouBegin InstallationFaucet Kit Not Shown PartsSierra Manifold Unit Parts Kit not ShownConnec- t o r FeedConnectionDrainConnection DrillingTheSinkFormica or Wooden Counter Enamel, Porcelain-Over-Steel, or Cast Iron Sink Tile Sink or CounterStainless Steel Sink PushHandleFaucet Manifold Unit InitialFlushingProcedure Activation/FlushingSystemActivation andInspection CheckList CartridgeReplacement Cartridges/TankTankSanitizing Nimbus Water Systems 2007 PN103257