Windsor CMPS2E, 10070560, 10070570 manual Vacuum Motor

Page 21

4. VACUUM MOTOR

(Refer to vacuum group in the parts section of manual).

ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS.

VACUUM MOTOR REPLACEMENT

1.Turn off all switches and unplug machine.

2.Remove recovery tank.

3.Remove the 5 screws holding the vacuum motor cover to the solution tank.

4.Locate the vacuum motor wires and disconnect at the connector.

5.Remove the vacuum motor.

6.Reverse process to install.

MAINTENANCE

Vacuum Motor Carbon Brushes Replacement (Windsor)

 

End Cap

Carbon

WARNING: The green

Brushes

ground wire must be

 

attached for safe operation.

 

See wiring diagram.

If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.

Important:

These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.

38 [9.5mm]

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.

CMPS2 86305210 11/21/07

4-3

Image 21
Contents Multi-Functional Cleaning Overview Machine Data LOG/OVERVIEWTable of Contents HOW to USE this Manual Important Safety Instructions Hazard Intensity Level Hazard Intensity LevelThis Product is for Commercial USE only Electrical Grounding InstructionsSafety Label Location Technical Specifications HOW the Machine Works Components Controls Solution Accessory Tool HOOK-UP Filling the Machine OperationsOperations Unloader Valve Do not let pump run dry Do not let pump run unattended CMPS2 86305210 11/21/07 Maintenance Float SHUT-OFF Vacuum Motor Pump Replacement Kits Service Schedule Problem Cause Solution TroubleshootingCMPS2 86305210 11/21/07 Control Panel PRV no QTY Description Serial no From Decal LABEL, Windsor Compass Control Solution Tank SCR, 8 X 3/4 PFHT/S BLK Zinc SOLUTION-INJECTOR Assembly ELBOW, 1/4FPT X 1/4FPT Solution Injector AssemblySOLUTION-PUMP HOSE, PULSE, 1/4MSWL X 3/8NPT SOLUTION-PUMP HOSEBARB, 3/8 MPT X 3/8 Nylon Recovery Tank WASHER, 5/16 Flat SS Vacuum CLAMP, 2.25 Worm Gear Wheels & Frame Wheels & Frame TOOLS- Standard TOOL, Hand Squeegee Power Cord Connection Wiring SchematicHARNESS, Main Wiring DiagramEMI Suggested Spare Parts VAC Hose Rack Option CLAMP, 1/4X1/4 BLT VIN DP TOOLS- Grout CLEANER-OPTION NIPPLE, 1/8 Close Tools Grout CLEANER-OPTIONTOOLS- High Pressure WAND-OPTION Tools High Pressure WAND-OPTION TOOLS- Carpet TOOL- Option Tools Carpet TOOL- Option Storage BAG-OPTION KIT, Storage BAG Chemical LOCK-OPTION Chemical LOCK-OPTION Serial Numbers

CMPS2E, CMPS2, 10070560, 10070570 specifications

Windsor CMPS2 is a leading-edge maintenance and monitoring solution designed to optimize performance and reliability in various applications. It serves as an integral part of the Windsor family of products, featuring the model numbers CMPS2, 10070570, CMPS2E, and 10070560. This system is engineered with the latest advancements in sensor technology and data analytics, making it an ideal choice for businesses looking to enhance operational efficiency.

One of the main features of the Windsor CMPS2 is its ability to monitor performance in real-time, providing critical data and insights that allow operators to make informed decisions. The system is equipped with advanced sensors that track various parameters such as temperature, pressure, and humidity. This data is transmitted to a centralized dashboard, enabling users to visualize trends and identify potential issues before they escalate into costly problems.

The CMPS2 incorporates state-of-the-art wireless technology, allowing for seamless connectivity and integration with existing infrastructure. This feature is particularly beneficial for organizations that operate across multiple locations, as it facilitates centralized management and remote access to data. Additionally, the system supports cloud-based storage and analytics, ensuring that vital information is always accessible and can be analyzed in real-time.

Another standout characteristic of the Windsor CMPS2 is its enhanced user interface, designed for ease of use. The intuitive dashboard presents data in easily digestible formats, incorporating graphs and alert systems that notify users of critical changes. This user-centric design minimizes training time for new operators and improves overall productivity.

Moreover, the Windsor CMPS2 is built with durability and reliability in mind, featuring rugged components that can withstand harsh operational environments. Its robust construction guarantees prolonged life and reduced maintenance costs, making it a cost-effective solution for businesses of all sizes.

In summary, the Windsor CMPS2, along with model numbers 10070570, CMPS2E, and 10070560, offers an array of sophisticated features, including real-time monitoring, advanced sensors, wireless connectivity, and a user-friendly interface. With its emphasis on performance optimization and ease of use, the Windsor CMPS2 stands out as a versatile tool that can significantly enhance operational efficiency and reliability across various industries.