Windsor CMPS2E, 10070560, 10070570 manual CLAMP, 2.25 Worm Gear

Page 41

 

 

 

 

 

 

VACUUM

 

 

 

 

 

 

 

REF

PART NO.

PRV NO.

QTY

DESCRIPTION

SERIAL NO.

NOTES:

FROM

 

 

 

 

 

 

1

86237870

35270

1

GASKET, 5.0 OD X 2.38 ID X .25T

 

 

2

86002380

20046

1

CLAMP, 2.25” WORM GEAR

 

 

3

86281180

39298

1

HOSE, 2.0 VAC EXHAUST X 17”

 

 

4

86240240

39697

1

HOSE, 3.15 ID X 7.0L VENT

 

 

5

86233260

20092

1

CLAMP, 3.5” WORM GEAR

 

 

6

86274370

70191

1

SCR, 10-24 X 1/2 HHTC TYPE 23

 

 

7

86005810

57245

3

NUT, 1/4-20 HEX NYLOCK SS

 

 

8

86010640

87016

1

WASHER, #10 LOCK EXT STAR SS

 

 

9

86201970

065-92

3

VAC SPACER 2 1/4 (2 STAGE)

 

 

10

86003760

35166

1

GASKET, VAC MTR

 

 

11

86296140

-

1

COVER, VAC MOTOR

 

 

12

86010630

87013

9

WASHER, 1/4 ID X 5/8 OD SS

 

 

13

86007010

70663

3

SCR, 1/4-20 X 3 1/4 HHCS PLT

 

 

14

86010670

87029

5

WASHER, 5/16 FLAT SS

 

 

15

86277040

70781

5

SCR, 5/16-18 X 1/2 HHCS SS NP

 

 

16A

86303840

-

1

VAC MTR, 120V 5.7 2 ST TD

 

115V

-

86135320

140687

-

BRUSH SET, 120V VAC WINDSOR

 

115V

16B

86304640

-

1

ASSY, VAC MOTOR, 230V

 

230V

-

86135330

-

-

BRUSH SET, 230V VAC MTR

 

230V

CMPS2 86305210 04/23/08

5-16

Image 41
Contents Multi-Functional Cleaning Overview Machine Data LOG/OVERVIEWTable of Contents HOW to USE this Manual Important Safety Instructions Hazard Intensity Level Hazard Intensity LevelThis Product is for Commercial USE only Electrical Grounding InstructionsSafety Label Location Technical Specifications HOW the Machine Works Components Controls Solution Accessory Tool HOOK-UP Filling the Machine OperationsOperations Unloader Valve Do not let pump run dry Do not let pump run unattended CMPS2 86305210 11/21/07 Maintenance Float SHUT-OFF Vacuum Motor Pump Replacement Kits Service Schedule Problem Cause Solution TroubleshootingCMPS2 86305210 11/21/07 Control Panel PRV no QTY Description Serial no From Decal LABEL, Windsor Compass Control Solution Tank SCR, 8 X 3/4 PFHT/S BLK Zinc SOLUTION-INJECTOR Assembly ELBOW, 1/4FPT X 1/4FPT Solution Injector AssemblySOLUTION-PUMP HOSE, PULSE, 1/4MSWL X 3/8NPT SOLUTION-PUMP HOSEBARB, 3/8 MPT X 3/8 Nylon Recovery Tank WASHER, 5/16 Flat SS Vacuum CLAMP, 2.25 Worm Gear Wheels & Frame Wheels & Frame TOOLS- Standard TOOL, Hand Squeegee Power Cord Connection Wiring SchematicHARNESS, Main Wiring DiagramEMI Suggested Spare Parts VAC Hose Rack Option CLAMP, 1/4X1/4 BLT VIN DP TOOLS- Grout CLEANER-OPTION NIPPLE, 1/8 Close Tools Grout CLEANER-OPTIONTOOLS- High Pressure WAND-OPTION Tools High Pressure WAND-OPTION TOOLS- Carpet TOOL- Option Tools Carpet TOOL- Option Storage BAG-OPTION KIT, Storage BAG Chemical LOCK-OPTION Chemical LOCK-OPTION Serial Numbers

CMPS2E, CMPS2, 10070560, 10070570 specifications

Windsor CMPS2 is a leading-edge maintenance and monitoring solution designed to optimize performance and reliability in various applications. It serves as an integral part of the Windsor family of products, featuring the model numbers CMPS2, 10070570, CMPS2E, and 10070560. This system is engineered with the latest advancements in sensor technology and data analytics, making it an ideal choice for businesses looking to enhance operational efficiency.

One of the main features of the Windsor CMPS2 is its ability to monitor performance in real-time, providing critical data and insights that allow operators to make informed decisions. The system is equipped with advanced sensors that track various parameters such as temperature, pressure, and humidity. This data is transmitted to a centralized dashboard, enabling users to visualize trends and identify potential issues before they escalate into costly problems.

The CMPS2 incorporates state-of-the-art wireless technology, allowing for seamless connectivity and integration with existing infrastructure. This feature is particularly beneficial for organizations that operate across multiple locations, as it facilitates centralized management and remote access to data. Additionally, the system supports cloud-based storage and analytics, ensuring that vital information is always accessible and can be analyzed in real-time.

Another standout characteristic of the Windsor CMPS2 is its enhanced user interface, designed for ease of use. The intuitive dashboard presents data in easily digestible formats, incorporating graphs and alert systems that notify users of critical changes. This user-centric design minimizes training time for new operators and improves overall productivity.

Moreover, the Windsor CMPS2 is built with durability and reliability in mind, featuring rugged components that can withstand harsh operational environments. Its robust construction guarantees prolonged life and reduced maintenance costs, making it a cost-effective solution for businesses of all sizes.

In summary, the Windsor CMPS2, along with model numbers 10070570, CMPS2E, and 10070560, offers an array of sophisticated features, including real-time monitoring, advanced sensors, wireless connectivity, and a user-friendly interface. With its emphasis on performance optimization and ease of use, the Windsor CMPS2 stands out as a versatile tool that can significantly enhance operational efficiency and reliability across various industries.