Windsor CMPS2E, 10070560, 10070570 manual HOW to USE this Manual

Page 4

HOW TO USE THIS MANUAL

This manual contains the following sections:

-HOW TO USE THIS MANUAL

-SAFETY

-OPERATIONS

-MAINTENANCE

-PARTS LIST

The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.

Parts may be ordered from authorized Windsor dealers. When placing an order for parts, the machine model and machine serial number are important. Refer to the MACHINE DATA box which is filled out during the installation of your machine. The MACHINE DATA box is located on the inside of the front cover of this manual.

MODEL __________________________________

DATE OF PURCHASE _____________________

SERIAL NUMBER ________________________

SALES REPRESENTATIVE # _______________

The model and serial number of your machine is on the bottom back-end of the machine.

The SAFETY section contains important information regarding hazard or unsafe practices of the machine. Levels of hazards is identified that could result in product or personal injury, or severe injury resulting in death.

The OPERATIONS section is to familiarize the operator with the operation and function of the machine.

The MAINTENANCE section contains preventive maintenance to keep the machine and its components in good working condition. They are listed in this general order:

-Vacuum Motor

-Solution Pump

-Daily Maintenance

-Periodic Maintenance

-Service Schedule

-Machine Troubleshooting

The PARTS LIST section contains assembled parts illustrations and corresponding parts list. The parts lists include a number of columns of information:

-REF – column refers to the reference number on the parts illustration.

-PART NO. – column lists the part number for the part.

-PRV NO. - reference number.

-QTY – column lists the quantity of the part used in that area of the machine.

-DESCRIPTION – column is a brief description of the part.

-SERIAL NO. FROM – If this column has an (*) and a Reference number, see the SERIAL NUMBERS page in the back of your manual. If column has two asterisk (**), call manufacturer for serial number. The serial number indicates the first machine the part number is applicable to. The main illustration shows the most current design of the machine. When a boxed illustration is shown, it displays the older design.

-NOTES – column for information not noted by the other columns.

NOTE: If a service or option kit is installed on your machine, be sure to keep the KIT INSTRUCTIONS which came with the kit. It contains replacement parts numbers needed for ordering future parts.

1-1

CMPS2 86305210 04/23/08

 

Image 4
Contents Multi-Functional Cleaning Machine Data LOG/OVERVIEW OverviewTable of Contents HOW to USE this Manual Important Safety Instructions Hazard Intensity Level Hazard Intensity LevelGrounding Instructions This Product is for Commercial USE only ElectricalSafety Label Location Technical Specifications HOW the Machine Works Components Controls Solution Accessory Tool HOOK-UP Operations Filling the MachineOperations Unloader Valve Do not let pump run dry Do not let pump run unattended CMPS2 86305210 11/21/07 Maintenance Float SHUT-OFF Vacuum Motor Pump Replacement Kits Service Schedule Troubleshooting Problem Cause SolutionCMPS2 86305210 11/21/07 Control Panel PRV no QTY Description Serial no From Decal LABEL, Windsor Compass Control Solution Tank SCR, 8 X 3/4 PFHT/S BLK Zinc SOLUTION-INJECTOR Assembly Solution Injector Assembly ELBOW, 1/4FPT X 1/4FPTSOLUTION-PUMP HOSE, PULSE, 1/4MSWL X 3/8NPT SOLUTION-PUMP HOSEBARB, 3/8 MPT X 3/8 Nylon Recovery Tank WASHER, 5/16 Flat SS Vacuum CLAMP, 2.25 Worm Gear Wheels & Frame Wheels & Frame TOOLS- Standard TOOL, Hand Squeegee Wiring Schematic Power Cord ConnectionWiring Diagram HARNESS, MainEMI Suggested Spare Parts VAC Hose Rack Option CLAMP, 1/4X1/4 BLT VIN DP TOOLS- Grout CLEANER-OPTION Tools Grout CLEANER-OPTION NIPPLE, 1/8 CloseTOOLS- High Pressure WAND-OPTION Tools High Pressure WAND-OPTION TOOLS- Carpet TOOL- Option Tools Carpet TOOL- Option Storage BAG-OPTION KIT, Storage BAG Chemical LOCK-OPTION Chemical LOCK-OPTION Serial Numbers

CMPS2E, CMPS2, 10070560, 10070570 specifications

Windsor CMPS2 is a leading-edge maintenance and monitoring solution designed to optimize performance and reliability in various applications. It serves as an integral part of the Windsor family of products, featuring the model numbers CMPS2, 10070570, CMPS2E, and 10070560. This system is engineered with the latest advancements in sensor technology and data analytics, making it an ideal choice for businesses looking to enhance operational efficiency.

One of the main features of the Windsor CMPS2 is its ability to monitor performance in real-time, providing critical data and insights that allow operators to make informed decisions. The system is equipped with advanced sensors that track various parameters such as temperature, pressure, and humidity. This data is transmitted to a centralized dashboard, enabling users to visualize trends and identify potential issues before they escalate into costly problems.

The CMPS2 incorporates state-of-the-art wireless technology, allowing for seamless connectivity and integration with existing infrastructure. This feature is particularly beneficial for organizations that operate across multiple locations, as it facilitates centralized management and remote access to data. Additionally, the system supports cloud-based storage and analytics, ensuring that vital information is always accessible and can be analyzed in real-time.

Another standout characteristic of the Windsor CMPS2 is its enhanced user interface, designed for ease of use. The intuitive dashboard presents data in easily digestible formats, incorporating graphs and alert systems that notify users of critical changes. This user-centric design minimizes training time for new operators and improves overall productivity.

Moreover, the Windsor CMPS2 is built with durability and reliability in mind, featuring rugged components that can withstand harsh operational environments. Its robust construction guarantees prolonged life and reduced maintenance costs, making it a cost-effective solution for businesses of all sizes.

In summary, the Windsor CMPS2, along with model numbers 10070570, CMPS2E, and 10070560, offers an array of sophisticated features, including real-time monitoring, advanced sensors, wireless connectivity, and a user-friendly interface. With its emphasis on performance optimization and ease of use, the Windsor CMPS2 stands out as a versatile tool that can significantly enhance operational efficiency and reliability across various industries.