Windsor ADM8, 10080170 operating instructions Maintenance, Solution Pump Replacement

Page 22
SOLUTION PUMP REPLACEMENT

!WARNING:

MAINTENANCE

ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS.

`

SOLUTION PUMP REPLACEMENT

1.Turn off all switches and unplug the machine.

2.Remove recovery tank.

3.Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.

4.Remove solution hoses from fittings in pump.

5.Remove the (2) screws that fasten the pump to the frame.

6.Reverse process to install pump.

86161980 PUMP REPLACEMENT KITS SHURFLO 100 PSI 86026390 PRV NO. (65201) PRV NO. 250-67

Switch Asm

Pump Head Replacement

Bypass Valve Asm

Diaphragm

8251040

86258830

86235100

PRV NO. 65187

PRV NO. 84161

PRV NO. 29206

PUMP REPLACEMENT PARTS FOR FLOJET 100 PSI PRIOR TO SERIAL # *

 

Pump Head

 

Motor

86251090

86247360

PRV NO. 65204

PRV NO. 53245

 

 

Valve Asm

Diaphragm

86258860

86235120

PRV NO. 84166

PRV NO. 29219

4-5

ADMIRAL 86038230 03/16/07

Image 22
Contents CARPET EXTRACTOR Operating InstructionsMODEL ADM810080170 86038320 03/16/07 PRV NOYOUR DEALER MACHINE DATA LOG/OVERVIEWMODEL SAFETY TABLE OF CONTENTSHOW TO USE THIS MANUAL MAINTENANCEHOW TO USE THIS MANUAL This machine is for commercial use SAFETY INSTRUCTIONSREAD ALL INSTRUCTIONS BEFORE USING THIS MACHINE IMPORTANT SAFETY INSTRUCTIONSFOR SAFETY HAZARD INTENSITY LEVELHAZARD INTENSITY LEVEL WHEN SERVICING MACHINEELECTRICAL GROUNDING INSTRUCTIONSGROUNDING INSTRUCTIONS GENERAL DIMENSIONS/WEIGHT TECHNICAL SPECIFICATIONSPOWER TYPE BRUSH SPEED 1000 rpmCONTROLS/COMPONENT LOCATIONS 10.Recovery Dump Hose. Facilitates draining11.Solution Dump Hose. Facilitates draining 3.Electrical CordCONTROLS/COMPONENT LOCATIONS 6.Recovery Tank Dome 7.Vacuum Shoe11 1 9 2 CONTROLS/COMPONENT LOCATIONS 1.Solution Intake Cover 2.Vacuum Intake Cover3.Float Shut-Off 4.Clean-OutOpening 5.Pour Spout 6.Lift HandleFILLING OPERATIONS CHEMICALSOPERATIONS CORRECT INCORRECTAdjust handle to comfortable operating OPERATIONSCLEANING PROCEDURE CLEANING PROCEDURE STEPAPRV NO ACCESSORY TOOL USAGE3-10 SERVICE SCHEDULE MAINTENANCE PERIODIC MAINTENANCE MAINTENANCE DAILY / REGULAR MAINTENANCE Vacuum Motor Carbon Brushes Replacement Windsor VACUUM MOTOR REPLACEMENTMAINTENANCE Vacuum Motor Carbon Brushes Replacement Ametek86249420 PRV NO. 86287330 PRV NO BELT REPLACEMENTMAINTENANCE MAINTENANCE SOLUTION PUMP REPLACEMENT86268460 WIRING DIAGRAM86268290 86268430SOLUTION TROUBLESHOOTING CHARTPROBLEM CAUSEADMIRAL 86038230 03/16/07 SEE PG FRAME ASSEMBLYSEE PG FRAME ASSEMBLY 16 12 BRUSH ASSEMBLY27 19 2030 BRUSH ASSEMBLY PUMP ASSEMBLY SEE PGPUMP ASSEMBLY VACUUM SHOE ASSEMBLY ADMIRAL 86038230 03/16/07VACUUM SHOE ASSEMBLY CONTROL PANEL ASSEMBLY SEE PG5-10 CONTROL PANEL ASSEMBLYSEE PG SOLUTION TANK ASSEMBLY12 12A 10 12B 20 15 7 11 14*195-12 SOLUTION TANK ASSEMBLY5-13 RECOVERY TANK ASSEMBLYADMIRAL 86038230 03/16/07 5-14 RECOVERY TANK ASSEMBLYSUGGESTED SPARE PARTS 5-15