TROUBLESHOOTING CHART

TROUBLESHOOTING CHART

PROBLEM

CAUSE

No Power, Nothing

Is the cord plugged in.

Circuit breaker tripped in building.

Runs

Faulty switch.

 

 

Faulty power cord or pigtail.

 

Vacuum circuit breaker tripped.

Vacuum Motor Will Not

Faulty main vacuum switch.

Run

Loose wiring.

 

Faulty vac motor.

 

Carbon brushes worn.

 

 

 

Debris lodged in vac shoe.

Vacuum Motor Runs

Dome gasket defective or missing.

But

.Vacuum hose cracked or hose cuff loose.

Suction Is Poor

Recovery tank full / float ball stuck in the

 

up position.

 

.Main pump switch off.

Poor Or No Water Flow

Jets clogged or missing.

(Carpet Is Streaky)

 

 

Solution filter clogged.

 

 

 

Faulty solenoid.

Brush Does Not Spin

Brush switch off.

Brush circuit breaker tripped.

 

 

Brush belt broken.

 

Faulty brush motor.

SOLUTION

Plug in cord. Reset breaker. Call for service. Call for service. Reset breaker. Call for service. Call for service. Call for service.

See “Brush Replacement” in maintenance section. Remove debris from vac shoe. Replace as necessary. Replace or repair as necessary. Turn off vac motor. Drain and rinse recovery tank.

Turn on.

Clean using a vinegar /water solution or replace.

Drain solution tank and clean solution filter.

Call for service.

Turn on brush switch. Reset circuit breaker. Replace as necessary. Call for service.

4-7

ADMIRAL 86038230 03/16/07

Image 24
Contents Operating Instructions MODEL ADM810080170CARPET EXTRACTOR 86038320 03/16/07 PRV NOMACHINE DATA LOG/OVERVIEW YOUR DEALERMODEL TABLE OF CONTENTS HOW TO USE THIS MANUALSAFETY MAINTENANCEHOW TO USE THIS MANUAL SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THIS MACHINEThis machine is for commercial use IMPORTANT SAFETY INSTRUCTIONSHAZARD INTENSITY LEVEL HAZARD INTENSITY LEVELFOR SAFETY WHEN SERVICING MACHINEGROUNDING INSTRUCTIONS ELECTRICALGROUNDING INSTRUCTIONS TECHNICAL SPECIFICATIONS POWER TYPEGENERAL DIMENSIONS/WEIGHT BRUSH SPEED 1000 rpm10.Recovery Dump Hose. Facilitates draining 11.Solution Dump Hose. Facilitates drainingCONTROLS/COMPONENT LOCATIONS 3.Electrical Cord6.Recovery Tank Dome 7.Vacuum Shoe CONTROLS/COMPONENT LOCATIONS11 1 9 2 1.Solution Intake Cover 2.Vacuum Intake Cover 3.Float Shut-Off 4.Clean-OutOpening 5.Pour SpoutCONTROLS/COMPONENT LOCATIONS 6.Lift HandleFILLING OPERATIONS CHEMICALSOPERATIONS CORRECT INCORRECTAdjust handle to comfortable operating OPERATIONSCLEANING PROCEDURE CLEANING PROCEDURE STEPACCESSORY TOOL USAGE APRV NO3-10 SERVICE SCHEDULE MAINTENANCEMAINTENANCE PERIODIC MAINTENANCEDAILY / REGULAR MAINTENANCE VACUUM MOTOR REPLACEMENT MAINTENANCEVacuum Motor Carbon Brushes Replacement Windsor Vacuum Motor Carbon Brushes Replacement Ametek BELT REPLACEMENT 86249420 PRV NO. 86287330 PRV NO MAINTENANCE MAINTENANCE SOLUTION PUMP REPLACEMENTWIRING DIAGRAM 8626829086268460 86268430TROUBLESHOOTING CHART PROBLEMSOLUTION CAUSEADMIRAL 86038230 03/16/07 FRAME ASSEMBLY SEE PGSEE PG FRAME ASSEMBLY BRUSH ASSEMBLY 16 1227 19 2030 BRUSH ASSEMBLY PUMP ASSEMBLY SEE PGPUMP ASSEMBLY VACUUM SHOE ASSEMBLY ADMIRAL 86038230 03/16/07VACUUM SHOE ASSEMBLY CONTROL PANEL ASSEMBLY SEE PG5-10 CONTROL PANEL ASSEMBLYSOLUTION TANK ASSEMBLY 12 12A 10 12BSEE PG 20 15 7 11 14*195-12 SOLUTION TANK ASSEMBLYRECOVERY TANK ASSEMBLY 5-13ADMIRAL 86038230 03/16/07 5-14 RECOVERY TANK ASSEMBLYSUGGESTED SPARE PARTS 5-15