PERIODIC MAINTENACE
Twice a month, flush a white vinegar solution (one quart vinegar to two gallons of water) or anti- browning solution (mixed as directed) through the machine. This will prevent
NOTE: Do not use pins, wires, etc. to clean nozzles as this could destroy the spray pattern.
Periodically inspect all hoses, electrical cables and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. The electrical cable must be well insulated and cable connector screw kept tight. If the cable insulation is broken or frayed, repair or replace immediately. Don’t take chances with elctrical fire or shock.
MAINTENANCE
DAILY/REGULAR MAINTENANCE
Before making any adjustments to the machine, disconnect the power cord from the electrical source.
1.Empty unused cleaning solution from the solution tank.
2.Inspect and clean filter screen in solution tank.
3.Flush pumping system with 4 to 7 liters of clean water.
4.After each use, rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a
5.Remove filter to clean. Filters used for wet pick- up including striper must be thoroughly cleaned before being allowed to dry.
6.Check spray jets for full spray pattern.
NOTE: Worn filters can affect vacuum performance. Replace the filter when it becomes worn out and normal cleaning will not restore vac performance.
SERVICE SCHEDULE | DAILY | WEEKLY | QUARTERLY |
Check machine for cord damage | * |
|
|
Check recovery dome and gasket for damage and | * |
|
|
cleanliness |
|
| |
Check hoses for wear, blockages, or damage | * |
|
|
Check handles, switches, and knobs for damage | * |
|
|
Check vac motor intake filter and clean | * |
|
|
Run one gallon of water through system | * |
|
|
|
|
| |
Clean out recovery tank and check float valve to make | * |
|
|
sure it moves freely |
|
| |
Clean out solution tank and remove and clean vacuum | * |
|
|
intake screen |
|
| |
Clean outside of all tanks and check for damage | * |
|
|
Run vac motor for at least one minute to allow motor to | * |
|
|
dry |
|
| |
Store with dome off tank to allow the tank to dry | * |
|
|
Check all bearings for noise |
| * |
|
Check all gaskets for wear and leakage |
| * |
|
Check vacuum intake screen for damage; replace if |
| * |
|
necessary |
|
| |
Check pump pressure; observe spray pattern and |
| * |
|
check with gauge if necessary |
|
| |
Check and clean solution screen |
| * |
|
Check cables for fraying |
| * |
|
Check overall performance of machine |
| * |
|
Check vac motor carbon brushes |
|
| * |
CMPS 86290230 02/22/07 |