Watson & Sons 520DUN user manual Pump is now ready to operate

Page 23

13 Switching the pump on in subsequent power cycles (if not in auto-restart mode)

￿Switch on the power supply at the rear of the pump. The pump runs a power- on test to confirm proper functioning of the memory and hardware. If a fault is found, an error message is displayed. See 25.1 Error codes.

￿The pump displays the Watson-Marlow start-up screen for four seconds fol- lowed by the pump model identity screen for four seconds, and then the manu- al mode main screen.

￿Note: If ANY key is pressed during the display of any of the preliminary screens, the display jumps to the next screen. Quickly pressing any two keys or any key twice immediately after switch-on causes the display to jump to the manual mode main screen. Once in the manual mode main screen, keys assume their normal functions - see 15.1 Keypad functions in manual mode below. A subsequent press on START causes the pump to operate.

￿Start-up defaults are those in place when the pump was switched off last. Check that the pump is set to operate as you require it.

The pump is now ready to operate.

All operating parameters may be changed by means of key-presses. See 14 Manual operation.

Watson-Marlow 520DuN IP66/NEMA 4X User Manual

23

Image 23
Contents Watson-Marlow 520DuN IP66/NEMA 4X pumps ContentsPublication history 104 Decontamination certificate 105 Declaration of incorporation Declaration of conformityExceptions Five year warrantyCased pumps, 620 cased pumps and 720 cased pumps ConditionsComponents supplied 520DuN pump, IP66 Nema 4X models When you unpack your pumpPackaging disposal InspectionStorage Information for returning pumpsSuitable applications Peristaltic pumps an overviewHow they work Safety notes Page Pump specifications Analogue control Remote control520DuN, IP66 Nema 4X model Manual controlNema IP Ingress Protection and Nema definitionsPump specifications Other StandardsHarmonised Standards520DuN IP66/NEMA 4X model Unit weights DimensionsDo’s and do not’s Good pump installation practiceGeneral recommendations Page Connecting this product to a power supply Page Page Start-up check list Switching the pump on for the first timeUser trim First-time start-up defaults LanguageAnalogue input SpeedPump is now ready to operate Manual operation Keypad functions in manual modePage Page Manual operation and remote digital inputs and outputs Keypad lockKeypad beep Keypad functions in menu screens Main menuMain menu entry PIN-secure process protection Calibrate Tube Head and tubeCalibration dose Page Setup menu SetupTrim Analogue Input 1 speed Program Scaling stroke TrimAlternatively DisplayBaud Pump number18.7 Xon/Xoff Stop bitsFlow units Run time Run / stop General alarmOutputs Parameters arePage Remote stop Page Auto-restart Backlight Set maximum speedLanguage 18.15 ROMBeep DefaultsSecurity code Exit Pin out detailsTo dispense a master dose MemoDoseTo repeat the dose Changing dosing speedExit To remove the 520N watertight module Automatic control wiring22.1 520N module removal and replacement To replace the 520N watertight module Wiring up Page Do not strap the control and mains power cables together Speed analogue input Scaling analogue input Tachometer frequency output Speed analogue outputDirection input SwitchRun / stop input Leak detection input Tube monitor 520N module Wire colourAuto / manual toggle input MemoDose inputImportant pump status outputs Outputs 1, 2, 3Supply voltages DC Voltage Max load Typical use 22.14 RS485 inputAutomatic control and operation How to get into auto operationHow to get out of auto operation Emergency stop Network control and operation How to get into network operationHow to get out of network operation Command Parameters Meaning 24.1 RS485 command stringsTroubleshooting Error condition Suggested action Error codesDrive spares Drive maintenance520REL/520REM/520REH 520R, 520R2 and 520RE pumpheadsIdentification of parts To reposition the track Pumphead position, removal and replacementRotor removal Rotor replacementOpening the pumphead guard 29 520R, 520R2 and 520RE installation29.2 520R and 520R2 tube loading 29.3 520RE fitting the drain port 2mm and 6.4mm Industrial Sanitary 29.4 520RE Element loading520REL Pressures Up to 2 bar 30 psi Pressures Up to 4 bar 60 psi Up to 7 bar 100 psiPage 29.5 520RE Element connection Sanitary 3⁄4in mini-Tri-clamp connectorsIndustrial quick-release connectors 30 520R, 520R2 and 520RE maintenance Chemical Cleaning precautions 31 520R, 520R2 and 520RE rotor settingsGeneral guide to cleaning with solvents 520R/520R2 520REL/520REM/520REH Pumphead spares520R and 520R2 Flow ratesPumping conditions 520RE 220rpm Continuous tubingElements Performance curves Page Page Page 6mm wall tubing for 520R pumpheads Tubing and element part numbersInch Chem-Sure Sta-Pure 4mm wall tubing for 520R2 pumpheadsInch Marprene Bioprene Pumpsil 913.A008.024102 4mm wall elements for 520RE pumpheadsSanitary Inch Bioprene TM Sta-Pure 103 35 520 series pumping accessoriesAccessory Description Part code Pump Compatibility 104 TrademarksPublication history 105 Decontamination certificateRGA number Signature Your position Date

520DUN specifications

Watson & Sons 520DUN is a state-of-the-art model that has garnered attention for its exceptional performance and innovative technologies. Designed for agricultural applications, this machine combines durability, efficiency, and ease of use, catering to the needs of modern farmers.

One of the standout features of the 520DUN is its robust engine. Equipped with a high-performance diesel engine, it offers impressive horsepower, allowing it to handle a variety of demanding tasks with ease. This engine is designed for fuel efficiency, ensuring that operators can complete their work without frequent refueling. The powertrain is complemented by an advanced transmission system that enables smooth gear shifts, enhancing operator comfort during long hours of operation.

The 520DUN also boasts a remarkable load capacity, making it an ideal choice for transporting heavy materials. Its rugged build quality ensures that it can withstand the rigors of daily use, providing a reliable solution for farmers and contractors alike. The robust chassis and reinforced components were designed to maintain stability and control, especially when navigating uneven terrain.

Incorporating cutting-edge technologies, the Watson & Sons 520DUN features precision farming capabilities. With GPS integration, operators can efficiently manage their fields, optimizing planting and harvesting processes. This technology not only increases yield but also minimizes inputs, making farming more sustainable and economically viable.

User ergonomics were a significant consideration in the design of the 520DUN. The operator's cabin is spacious and well-equipped with intuitive controls, providing a comfortable working environment. Operators will appreciate the advanced display panel that offers real-time data on performance metrics, fuel consumption, and maintenance reminders. This allows users to keep the machine in peak condition and react to any issues promptly.

Safety is also paramount in the design of the 520DUN. It features reinforced safety measures, including roll-over protection systems and visibility enhancements, ensuring operator safety during operations.

In summary, the Watson & Sons 520DUN represents the pinnacle of agricultural machinery with its powerful engine, remarkable load capacity, precision technology, and ergonomic design. It is tailored for those who seek reliability and efficiency in their agricultural endeavors, making it a noteworthy choice in today's competitive market.