Watson & Sons 520DUN user manual Defaults, Beep

Page 53

18.17 Defaults

All the pump’s user-set data can be reset to factory defaults.

￿In the fifth screen of the Setup menu select Defaults using the UP and DOWN keys. Press ENTER to confirm your choice.

￿A warning is displayed for four seconds, and the pump asks the user to confirm that factory defaults are to be reset. Use the UP and DOWN keys to choose Yes if you wish the pump to reset all user-set data back to factory defaults (see 12 Switching the pump on for the first time); or No if you do not wish to do this. Press ENTER to confirm your decision. If Yes was chosen, the pump will reset its factory defaults and redisplay the fifth Setup screen. If No was chosen, the pump will make no changes to its setup and redisplay the fifth Setup screen.

18.18 Beep

The pump keypad can operate silently or indicate a positive key-press with a beep sound.

￿In the fifth screen of the Setup menu select Beep using the UP and DOWN keys. Press ENTER to confirm your choice.

￿In the next screen, use the UP and DOWN keys to choose On or Off. Press ENTER to confirm your decision. The pump redisplays the fifth Setup screen.

Alternatively ...

To toggle the sound on and off, stop the pump. Turn off the mains power switch at the rear of the pump.

Depress the UP and DIRECTION keys while switching on the mains power switch at the rear of the pump.

Watson-Marlow 520DuN IP66/NEMA 4X User Manual

53

Image 53
Contents Watson-Marlow 520DuN IP66/NEMA 4X pumps ContentsPublication history 104 Decontamination certificate 105 Declaration of incorporation Declaration of conformityCased pumps, 620 cased pumps and 720 cased pumps Five year warrantyConditions ExceptionsPackaging disposal When you unpack your pumpInspection Components supplied 520DuN pump, IP66 Nema 4X modelsStorage Information for returning pumpsSuitable applications Peristaltic pumps an overviewHow they work Safety notes Page Pump specifications 520DuN, IP66 Nema 4X model Remote controlManual control Analogue controlNema IP Ingress Protection and Nema definitionsPump specifications Harmonised StandardsStandards Other520DuN IP66/NEMA 4X model Unit weights DimensionsDo’s and do not’s Good pump installation practiceGeneral recommendations Page Connecting this product to a power supply Page Page Start-up check list Switching the pump on for the first timeAnalogue input First-time start-up defaults LanguageSpeed User trimPump is now ready to operate Manual operation Keypad functions in manual modePage Page Manual operation and remote digital inputs and outputs Keypad lockKeypad beep Keypad functions in menu screens Main menuMain menu entry PIN-secure process protection Calibrate Tube Head and tubeCalibration dose Page Setup menu SetupTrim Analogue Input 1 speed Program Scaling stroke TrimAlternatively DisplayBaud Pump number18.7 Xon/Xoff Stop bitsFlow units Run time Outputs General alarmParameters are Run / stopPage Remote stop Page Auto-restart Backlight Set maximum speedLanguage 18.15 ROMBeep DefaultsSecurity code Exit Pin out detailsTo dispense a master dose MemoDoseTo repeat the dose Changing dosing speedExit To remove the 520N watertight module Automatic control wiring22.1 520N module removal and replacement To replace the 520N watertight module Wiring up Page Do not strap the control and mains power cables together Speed analogue input Scaling analogue input Tachometer frequency output Speed analogue outputDirection input SwitchRun / stop input Auto / manual toggle input Tube monitor 520N module Wire colourMemoDose input Leak detection inputImportant pump status outputs Outputs 1, 2, 3Supply voltages DC Voltage Max load Typical use 22.14 RS485 inputAutomatic control and operation How to get into auto operationHow to get out of auto operation Emergency stop Network control and operation How to get into network operationHow to get out of network operation Command Parameters Meaning 24.1 RS485 command stringsTroubleshooting Error condition Suggested action Error codesDrive spares Drive maintenance520REL/520REM/520REH 520R, 520R2 and 520RE pumpheadsIdentification of parts To reposition the track Pumphead position, removal and replacementRotor removal Rotor replacementOpening the pumphead guard 29 520R, 520R2 and 520RE installation29.2 520R and 520R2 tube loading 29.3 520RE fitting the drain port 520REL Pressures Up to 2 bar 30 psi 29.4 520RE Element loadingPressures Up to 4 bar 60 psi Up to 7 bar 100 psi 2mm and 6.4mm Industrial SanitaryPage 29.5 520RE Element connection Sanitary 3⁄4in mini-Tri-clamp connectorsIndustrial quick-release connectors 30 520R, 520R2 and 520RE maintenance Chemical Cleaning precautions 31 520R, 520R2 and 520RE rotor settingsGeneral guide to cleaning with solvents 520R/520R2 520REL/520REM/520REH Pumphead spares520R and 520R2 Flow ratesPumping conditions 520RE 220rpm Continuous tubingElements Performance curves Page Page Page 6mm wall tubing for 520R pumpheads Tubing and element part numbersInch Marprene Bioprene Pumpsil 4mm wall tubing for 520R2 pumpheads913.A008.024 Inch Chem-Sure Sta-Pure102 4mm wall elements for 520RE pumpheadsSanitary Inch Bioprene TM Sta-Pure 103 35 520 series pumping accessoriesAccessory Description Part code Pump Compatibility 104 TrademarksPublication history 105 Decontamination certificateRGA number Signature Your position Date

520DUN specifications

Watson & Sons 520DUN is a state-of-the-art model that has garnered attention for its exceptional performance and innovative technologies. Designed for agricultural applications, this machine combines durability, efficiency, and ease of use, catering to the needs of modern farmers.

One of the standout features of the 520DUN is its robust engine. Equipped with a high-performance diesel engine, it offers impressive horsepower, allowing it to handle a variety of demanding tasks with ease. This engine is designed for fuel efficiency, ensuring that operators can complete their work without frequent refueling. The powertrain is complemented by an advanced transmission system that enables smooth gear shifts, enhancing operator comfort during long hours of operation.

The 520DUN also boasts a remarkable load capacity, making it an ideal choice for transporting heavy materials. Its rugged build quality ensures that it can withstand the rigors of daily use, providing a reliable solution for farmers and contractors alike. The robust chassis and reinforced components were designed to maintain stability and control, especially when navigating uneven terrain.

Incorporating cutting-edge technologies, the Watson & Sons 520DUN features precision farming capabilities. With GPS integration, operators can efficiently manage their fields, optimizing planting and harvesting processes. This technology not only increases yield but also minimizes inputs, making farming more sustainable and economically viable.

User ergonomics were a significant consideration in the design of the 520DUN. The operator's cabin is spacious and well-equipped with intuitive controls, providing a comfortable working environment. Operators will appreciate the advanced display panel that offers real-time data on performance metrics, fuel consumption, and maintenance reminders. This allows users to keep the machine in peak condition and react to any issues promptly.

Safety is also paramount in the design of the 520DUN. It features reinforced safety measures, including roll-over protection systems and visibility enhancements, ensuring operator safety during operations.

In summary, the Watson & Sons 520DUN represents the pinnacle of agricultural machinery with its powerful engine, remarkable load capacity, precision technology, and ergonomic design. It is tailored for those who seek reliability and efficiency in their agricultural endeavors, making it a noteworthy choice in today's competitive market.