Replacing HEPA filter

The HEPA filter needs to be replaced every 2,000 working hours or when the HEPA icon flashes on the LCD display. The higher level of pollutants, the shorter the lifespan of the filter.

Remove the front cover, the pre-filter and the old HEPA filter.

Install the new HEPA filter with the arrow in the front to the air purifier.

Press the HEPA “RESET” button on the remote control to reset the HEPA filter timer.

Dispose of the old HEPA filter and do not reuse.

Cleaning the photo-catalyst filter

The photo-catalyst filter should be cleaned every 6 months depending on the air quality.

Remove the front cover, pre-filter and HEPA filter as shown in the above picture.

11

Image 11
Contents Whynter Eco Pure Air Purifier Table of Contents Important Safety Instructions Purification Technology Technical Data Hepa Parts OverviewControl Panel & Remote Control ON/OFF Turns on / off the air purifier Remote Control OperationPage Cleaning the pre-filter InstallationCleaning & Maintenance Replacing Hepa filter Cleaning the photo-catalyst filterReplacing the UV Lamp Cleaning the front coverTrouble Check list Solution TroubleshootingONE Year Limited Warranty