Vizio TZEMT400AB32MAA warranty Maint Service, 3000 HRS, Maintenance Service Screen

Page 20

Thermostat User Guide

Maint Service

The Maintenance Service screen will show the accumulated Heat and Cool Runtime hours as well as the Service Interval that will be used to trigger a Maintenance Message. Any HEAT or COOL type of HVAC operation will cause the respective Runtime values to increase.

When the combined HEAT and COOL Runtime hours equals the Service Interval hours, the Red LED will flash along with a “Maint” message to remind you your HVAC system may require periodic maintenance. Pressing the Menu button will take you to the Filter Service screen. The Reset button can be pressed and the HEAT and COOL Runtime values will be reset to zero.

The Service Interval period can be changed using the +/- buttons.

Maintenance Service Screen

Maintenance Service

Heat Runtime Cool Runtime

Service Interval

Don

 

+

0HRS

0 HRS

3000 HRS

Reset

Screen navigation buttons:

Done

+

Reset

Return to Main Menu Screen

Increase the Service Interval by 1 hour

Decrease the Service Interval by 1 hour

27

Image 20
Contents Contents User GuideProduct Specifications TZEMT400AB32MAADisplay operation OverviewWave Thermostat Wave Operation and Programming InclusionExclusion Inclusion and ExclusionOperation User Settings Screen ZWave InstallUsage Graph ESM SetpointsTemperature Display Thermostat Control ScreenSetpoint Display Clock DisplaySetpoint Up and Down Buttons Heating Cooling Down Setpoint Setting ButtonsThermostat Control Screen Buttons Menu Button Main Thermostat ScreenMode Operation Mode ButtonSystem Mode Screen Fan Mode Screen FAN ButtonRUN/HOLD/ESM Button Run/Hold/ESM ScreenLED Displays LED 1 Green System Operation displayMain Menu Menu SelectionDone Select Main MenuSchedules Screen SchedulesSelect Schedule Heat and Cool Schedules MondayDone Next Copy Schedule ScreenCopy Schedule Copy Monday ScheduleBack Copy Copy Schedule ScreenUser Settings User SettingsUser Settings Screen Menu optionsSet Clock Set ClockBack Set Set Clock ScreenFilter Service Filter Service Filter RuntimeService Interval 300 HRS Done Reset3000 HRS Maint ServiceMaintenance Service Screen Sensor Calibration SensorDone Sensor Calibration ScreenBacklite/Display Backlite Settings ScreenBacklite/Display Thermostat Info Screen Thermostat InfoThermostat Info Installer Settings Menu Hidden Screen System Settings Menu Mechanical Settings SubmenuInstaller Settings Menu Hidden Screen Fan Cycler SubmenuInstaller Settings Summary Setting Range DefaultInstaller Settings Installer Settings ScreenHvac System Connection Hvac System CompatibilityRemote Communications Multi-Stage Hvac CompatibilityStandard Gas/Electric Hvac System Wiring Installation Notes Standard Hvac System SetupHeat Pump Hvac System Wiring Installation Notes Heat Pump Hvac System SetupHvac System Operation and Setup SetupGeneral Heating and Cooling Operation Standard Hvac System TypesHeat Pump System Type Selection Changeover Type SelectionMinimum Run Time MRT Minimum Off Time MOTCommon or Split Transformer Systems InstallationPower Warranty A. and Canada Only