Vizio TZEMT400AB32MAA warranty Installer Settings Summary, Setting Range Default

Page 26

Thermostat User Guide

Installer Settings Summary

Setting

Range

Default

 

 

 

 

 

Display Lock

Y or N

N

Locks out front buttons

 

 

 

 

F/C Mode

C or F

F

 

 

 

 

 

Screen Timeout

0-240

0

seconds

 

 

 

 

 

 

 

 

Schedule Enable

Y or N

N

 

 

 

 

 

 

 

 

 

Max heat setpoint

55F-90F (12C-32C)

90F (32C)

 

 

 

 

 

Min cool setpoint

60F-99F(15C-37C)

55F (15C)

 

 

 

 

 

 

Min Run Time (MRT)

1

– 9

3

 

 

 

 

 

 

Min Off Time (MOT)

5

– 9

5

 

 

 

 

 

Mechanical - Type

Std or HP

Std

 

 

 

 

 

Mechanical - Fan Type

Gas or Elec

Gas

 

 

 

 

 

Mechanical - C/O Type

w/Heat or w/Cool

w/Cool

 

 

 

 

 

Mechanical - 2nd Stage

Y or N

N

 

Heat

 

 

 

 

 

 

 

 

Mechanical - Aux Heat

Y or N

Y

 

 

 

 

 

Mechanical - 2nd Stage

Y or N

N

 

Cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Filter Interval

 

 

300

 

 

 

 

 

 

Maint Interval

 

 

3000

 

 

 

 

 

 

 

 

 

 

 

H/C Delta

3

– 15

3

 

 

 

 

 

 

Heat Delta Stage 1 On

1

– 8

1

 

 

 

 

 

 

Heat Delta Stage 1 Off

0

– 8

0

 

 

 

 

 

 

Heat Delta Stage 2 On

1

– 8

2

 

 

 

 

 

 

Heat Delta Stage 2 Off

0

– 8

0

 

 

 

 

 

 

Heat Delta Stage 3 On

1

– 8

3

 

 

 

 

 

 

Heat Delta Stage 3 Off

0

– 8

0

 

 

 

 

 

 

Cool Delta Stage 1 On

1

– 8

1

 

 

 

 

 

 

Cool Delta Stage 1 Off

0

– 8

0

 

 

 

 

 

 

Cool Delta Stage 2 On

1

– 8

2

 

 

 

 

 

 

Cool Delta Stage 2 Off

0

– 8

0

 

 

 

 

 

 

Fan Cycler ON time

0

– 120

0

0 = Fan Cycler OFF

 

 

 

 

Fan Cycler Off Time

10 – 120

10

 

 

 

 

 

 

27

Image 26
Contents Contents User GuideProduct Specifications TZEMT400AB32MAADisplay operation OverviewWave Thermostat Exclusion Wave Operation and ProgrammingInclusion Inclusion and ExclusionOperation Usage Graph User Settings ScreenZWave Install ESM SetpointsSetpoint Display Temperature DisplayThermostat Control Screen Clock DisplaySetpoint Up and Down Buttons Heating Cooling Down Setpoint Setting ButtonsThermostat Control Screen Buttons Menu Button Main Thermostat ScreenMode Operation Mode ButtonSystem Mode Screen RUN/HOLD/ESM Button Fan Mode ScreenFAN Button Run/Hold/ESM ScreenLED Displays LED 1 Green System Operation displayDone Select Main MenuMenu Selection Main MenuSchedules Screen SchedulesSelect Schedule Done Next Copy Heat and Cool SchedulesMonday Schedule ScreenBack Copy Copy ScheduleCopy Monday Schedule Copy Schedule ScreenUser Settings Screen User SettingsUser Settings Menu optionsBack Set Set ClockSet Clock Set Clock ScreenService Interval 300 HRS Filter ServiceFilter Service Filter Runtime Done Reset3000 HRS Maint ServiceMaintenance Service Screen Done Sensor CalibrationSensor Sensor Calibration ScreenBacklite/Display Backlite Settings ScreenBacklite/Display Thermostat Info Screen Thermostat InfoThermostat Info Installer Settings Menu Hidden Screen System Settings Menu Mechanical Settings SubmenuInstaller Settings Menu Hidden Screen Fan Cycler SubmenuInstaller Settings Summary Setting Range DefaultInstaller Settings Installer Settings ScreenRemote Communications Hvac System ConnectionHvac System Compatibility Multi-Stage Hvac CompatibilityStandard Gas/Electric Hvac System Wiring Installation Notes Standard Hvac System SetupHeat Pump Hvac System Wiring Installation Notes Heat Pump Hvac System SetupGeneral Heating and Cooling Operation Hvac System Operation and SetupSetup Standard Hvac System TypesMinimum Run Time MRT Heat Pump System Type SelectionChangeover Type Selection Minimum Off Time MOTCommon or Split Transformer Systems InstallationPower Warranty A. and Canada Only