Wayne EEAUP250 warranty Maintenance and Troubleshooting

Page 2

Operating Instructions and Parts Manual

APPLICATION AND OPERATION (CONTINUED)

3.For best pump performance, unwind the hose before starting the pump. This will help remove any kinks or binds in the hose and allow the unit to pump with less restriction.

4.Set the pump on a hard, flat surface in the water. Do not set the pump directly on mud or sand surfaces. This will cause the inlet screen to clog.

5.The water level must be at least 1-3/4 inches for the pump to cycle, prime, and operate. Water levels less than 1-3/4 inches will not allow the impeller to contact water therefore no water will be pumped.

Do NOT handle pump with wet hands or when standing in water

or on a damp surface when the unit is operating or fails to operate. ALWAYS disconnect pump power cord from power source before handling.

6.Plug the pump into a 120 volt GFCI protected outlet. The pump will start automatically when the water reaches a depth of 1-3/4 inches. A priming delay of 2 seconds is programmed into the control to allow time for air to escape from the pumping chamber.

7.The pump will stop automatically once water has been removed to a depth of approximately 3/8 of an inch above the hard surface. The pump will not restart until the water depth rises to 1-3/4 inches or greater.

8.The pump will not allow itself to run dry. Once the pump detects that water is no longer being removed, it will shut down automatically. The pump must remain upright at all times in order for the water detection to function. The shaft seal depends on water for lubrication. Do not allow the pump to operate on its side or inverted.

Do NOT alter the pump to override the automatic water detector. The shaft seal depends on water for lubrication. Overriding this pump feature can cause the pump to run

dry and may damage the shaft seal and cause pump failure.

MAINTENANCE AND TROUBLESHOOTING

Pump starts automatically. Always disconnect electric supply

before attempting to install, service, relocate, or perform any maintenance. Failure to do so could result in fatal electrical shock.

Minimal service is required for this pump. The motor housing of the pump is completely sealed and requires no service. If pump should fail to operate, perform the following troubleshooting guidelines:

1.Verify pumping height does NOT exceed 15 feet (See Figure 1). If pumping height is greater than 15 feet, this pump will NOT operate.

2.Verify water depth is 1-3/4 inches or greater (See Figure 1).

Do NOT disassemble or alter this product in any way. Failure to

follow these instructions will result in serious injury or death.

15 FT MAXIMUM PUMPING HEIGHT

WATER LEVEL MINIMUM: 1-3/4 INCHES

Figure 1 - Pumping Height

3.To verify pump is operating correctly.

a.Disconnect pump from power source.

b.Connect hose adapter and discharge hose to pump.

c.Immerse pump in a bucket or tub of water at least 1-3/4 inches in depth.

d.Place the other end of the discharge hose outside the bucket, so the water will pump out.

e.Plug power cord into a grounded 120 volt GFCI power outlet. The pump should start after 2 seconds of detecting water. Once the pump removes the water to a depth of 3/8 inch, the pump will stop automatically.

f.If pump does NOT operate, unplug power cord and proceed to maintenance – step 5.

4.To verify discharge hose is free from a blockage.

a.Connect hose to another water source such as a faucet. If water flows through hose, return to step 3a. If water is restricted, verify discharge hose is unwound. Remove all kinks, bends, or obstructions in hose.

b.If pump is still NOT operating, proceed to step 6.

5.Periodic cleaning of pump is required to maintain performance of the pump. Follow the cleaning steps listed below:

a.Unplug the power cord.

b.Remove the four (4) base screws (Figure 2).

c.Remove the base and impeller plate.

d.Remove the debris and make sure the impeller turns freely.

e.Reinstall impeller plate, base, and screws.

6.Check the priming hole for obstruction. (Figure 2). Follow the cleaning steps listed below:

a.Unplug the power cord.

b.Remove the four (4) base screws (Figure 2).

c.Remove the base and impeller plate.

d.Use a pin or paperclip to clean the priming hole and air escape channel.

e.Reinstall impeller plate, base and screws.

www.waynepumps.com

2

Image 2
Contents Description Safety GuidelinesGeneral Safety Information UnpackingMaintenance and Troubleshooting FT Maximum Pumping Height Water Level Minimum 1-3/4 InchesPumping Height Symptom Possible CausesCorrective Action Pump will notLimited Warranty Adapter Kit 62060-001Information Générale SUR LA Sécurité DéballageDirectives DE Sécurité Application ET FonctionnementSi la pompe NE fonctionne PAS, passer à létape Maintenance ET DépannageApplication ET Fonctionnement suite Hauteur DE PompageMesures corrective Maintenance ET Dépannage SuiteSymptôme Causes possibles Hauteur DE PompageGarantie limitée Trousse Dadaptateur 62060-001Pautas DE Seguridad DescripciónDesempaque Aplicación Y FuncionamientoMínimo DE Nivel DE Agua 4,4 CM 1-3/4 Pulg Aplicación Y Funcionamiento continuaciónAltura Máxima DE Instrucciones ocasionará lesiones graves o la muerteSíntoma Causas posibles Acciones a tomar Problemas continuaciónMantenimiento Y Resolución DE Altura DE BombeoGarantía limitada Juego de adaptador

EEAUP250 specifications

Wayne EEAUP250 is a state-of-the-art electric utility pump designed to handle various water transfer tasks with exceptional efficiency and reliability. Built to cater to both residential and commercial needs, the EEAUP250 is a versatile solution for managing excess water in basements, construction sites, or during flood emergencies.

One of the standout features of the Wayne EEAUP250 is its powerful motor. Equipped with a robust 1/2 HP motor, this pump can move up to 3,000 gallons of water per hour, making it ideal for rapid water removal. This impressive flow rate ensures that any accumulation of water can be swiftly dealt with, minimizing the risk of water damage or complications due to flooding.

The Wayne EEAUP250 boasts a durable and lightweight thermoplastic construction, ensuring it is both portable and resilient against corrosion and wear. This design allows for easy transport, making it convenient for on-the-go water management tasks. Its compact size ensures that it can fit into tight spaces, which is particularly beneficial in cramped basements or construction zones.

Another key characteristic is the integrated automatic pump switch, which activates the pump when water levels rise above a certain threshold. This feature not only enhances convenience but also ensures that the pump operates efficiently, only engaging when necessary, thus conserving energy.

The pump's maximum discharge height of 25 feet signifies its capacity to handle both flat and elevated draining tasks. This makes it suitable for a variety of applications, from draining hot tubs and swimming pools to providing backup in case of stormwater overflow.

The Wayne EEAUP250 also includes a reliable and easy-to-clean pre-filter that prevents debris from clogging the pump intake. This ensures longevity and consistent performance, allowing users to rely on the pump under various conditions.

In summary, the Wayne EEAUP250 electric utility pump stands out for its powerful motor, durable construction, automatic activation, and versatility in handling different water removal challenges. Whether faced with routine maintenance or emergency situations, this pump is designed to deliver reliable performance and peace of mind. With its combination of innovative features and solid engineering, the EEAUP250 is an indispensable tool for any property owner or contractor dealing with water management issues.