Wayne EEAUP250 warranty Description, Unpacking, Safety Guidelines, General Safety Information

Page 1

Auto On-Off Water Removal Portable Pump

OPERATING INSTRUCTIONS & PARTS MANUAL

Please read and save these instructions. This manual contains important Safety Warnings and Operating Instructions. You will need to refer to it before attempting any application or maintenance. Always keep this manual with the unit so that it will be easily accessible. Failure to read and follow these warnings and instructions could result in property damage, serious injury or death.

DESCRIPTION

This portable, submersible utility pump is designed for automatic use in water. The units are equipped with a 9 ft. 3-prong grounding type power cord. The provided discharge adapter can be used for convenient attachment to a garden hose.

UNPACKING

Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are

EEAUP250

Risk of electric shock. This pump has NOT been tested for use in

swimming pool or marine areas. NEVER place pump in pools while people are in the water. Failure to follow COULD result in death or serious injury.

Risk of electric shock! Do NOT handle pump with wet hands or

when standing in water or on a damp surface. Failure to follow COULD result in death or serious injury.

damaged, contact customer service at 1-800-237-0987.

READ & FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS — DO NOT DISCARD

SAFETY GUIDELINES

Electric shock hazard! For installation

by a qualified electrician only. GFCI receptacles will provide protection against line to ground faults only. The ground fault receptacle does NOT limit the magnitude of fault current and will NOT prevent an electrical shock.

This manual contains information that is important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.

Danger indicates an imminently hazardous situation which, if NOT avoided, WILL result

in death or serious injury.

Warning indicates a potentially hazardous situation which, if NOT avoided, COULD

result in death or serious injury.

Caution indicates a potentially hazardous situation which, if NOT avoided, MAY result

in minor or moderate injury.

Notice indicates important information, that if

NOT followed, MAY cause damage to equipment.

This is the safety alert symbol. It is used to alert you to potential bodily injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

NOTE: Note indicates information that requires special attention.

GENERAL SAFETY INFORMATION

CALIFORNIA PROPOSITION 65

This product or its power cord may contain chemicals, including lead, known to the

State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

GENERAL SAFETY

• Read the manual(s) included with this product carefully. Be thoroughly familiar with the controls and the proper use of the equipment. Follow all instructions.

Only persons well acquainted with these rules of safe operation should be allowed to use the unit.

Keep away from children!

Risk of fire, explosion and/or death! death! Pump is NOT rated for use

with flammable/combustible liquids, vapors or dusts. Do NOT pump liquids that are NOT clear. Failure to follow these instructions will result in bodily injury or death.

1. Wear safety glasses at all times when working with pumps.

2.The unit MUST be plugged into a GFCI. For installation by a qualified electrician only.

3.Damage to the power cord or discharge hose may occur. Use the handle supplied on the pump.

APPLICATION AND OPERATION

Do NOT use pump if any part of the housing switch or probe is cracked, broken, or missing.

Always disconnect electric supply

before attempting to install, service, relocate, or perform any maintenance. If the power source is out of sight, lock and

tag in open (off) position to prevent unexpected power application. Failure to do so could result in fatal electrical shock!

Electric shock hazard. Use only Underwriters Laboratories

(UL)- listed extension cord with #16 gauge or larger wire that is labeled for outdoor use. Use polarized grounding type plugs only. Polarized plugs have one blade slightly wider than the other and can only be inserted one way into the outlet. Do NOT handle plug connector near water. Failure to follow these instructions will result in serious injury or death.

This unit is NOT designed for use as a sump pump or in sump

applications. This unit is NOT designed for use in septic tanks or underground vaults to pump raw sewage or effluents. NEVER use in hazardous or explosive locations.

1.This pump has been designed with 1-1/4 in. NPT discharge connection size. Attach pipe or fitting to the discharge or use the supplied garden hose adapter. Thread the female end of the garden hose to the male end of the elbow.

2.Be certain to use a hose washer (not included) on the garden hose for correct pump operation.

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

© 2011,353901-001 4/11

WAYNE/Scott Fetzer Company.

For parts, product & service information

visit www.waynepumps.com

 

Image 1
Contents General Safety Information Safety GuidelinesDescription UnpackingFT Maximum Pumping Height Water Level Minimum 1-3/4 Inches Maintenance and TroubleshootingCorrective Action Symptom Possible CausesPumping Height Pump will notAdapter Kit 62060-001 Limited WarrantyDirectives DE Sécurité DéballageInformation Générale SUR LA Sécurité Application ET FonctionnementApplication ET Fonctionnement suite Maintenance ET DépannageSi la pompe NE fonctionne PAS, passer à létape Hauteur DE PompageSymptôme Causes possibles Maintenance ET Dépannage SuiteMesures corrective Hauteur DE PompageTrousse Dadaptateur 62060-001 Garantie limitéeDesempaque DescripciónPautas DE Seguridad Aplicación Y FuncionamientoAltura Máxima DE Aplicación Y Funcionamiento continuaciónMínimo DE Nivel DE Agua 4,4 CM 1-3/4 Pulg Instrucciones ocasionará lesiones graves o la muerteMantenimiento Y Resolución DE Problemas continuaciónSíntoma Causas posibles Acciones a tomar Altura DE BombeoJuego de adaptador Garantía limitada

EEAUP250 specifications

Wayne EEAUP250 is a state-of-the-art electric utility pump designed to handle various water transfer tasks with exceptional efficiency and reliability. Built to cater to both residential and commercial needs, the EEAUP250 is a versatile solution for managing excess water in basements, construction sites, or during flood emergencies.

One of the standout features of the Wayne EEAUP250 is its powerful motor. Equipped with a robust 1/2 HP motor, this pump can move up to 3,000 gallons of water per hour, making it ideal for rapid water removal. This impressive flow rate ensures that any accumulation of water can be swiftly dealt with, minimizing the risk of water damage or complications due to flooding.

The Wayne EEAUP250 boasts a durable and lightweight thermoplastic construction, ensuring it is both portable and resilient against corrosion and wear. This design allows for easy transport, making it convenient for on-the-go water management tasks. Its compact size ensures that it can fit into tight spaces, which is particularly beneficial in cramped basements or construction zones.

Another key characteristic is the integrated automatic pump switch, which activates the pump when water levels rise above a certain threshold. This feature not only enhances convenience but also ensures that the pump operates efficiently, only engaging when necessary, thus conserving energy.

The pump's maximum discharge height of 25 feet signifies its capacity to handle both flat and elevated draining tasks. This makes it suitable for a variety of applications, from draining hot tubs and swimming pools to providing backup in case of stormwater overflow.

The Wayne EEAUP250 also includes a reliable and easy-to-clean pre-filter that prevents debris from clogging the pump intake. This ensures longevity and consistent performance, allowing users to rely on the pump under various conditions.

In summary, the Wayne EEAUP250 electric utility pump stands out for its powerful motor, durable construction, automatic activation, and versatility in handling different water removal challenges. Whether faced with routine maintenance or emergency situations, this pump is designed to deliver reliable performance and peace of mind. With its combination of innovative features and solid engineering, the EEAUP250 is an indispensable tool for any property owner or contractor dealing with water management issues.