Features

Locking bayonet ring for accessory and reflector fitting

Tilthead whit 5/8" - inch stand socket

Thermal safety

User replaceable flash tube UV coated (5650°K)

Halogen modelling lamp 250W, with E27 fitting, and 300W/GX6.35for Style 1200RX (230V Version)

Silent fan cooling

Controls for: modelling on/off, cell on/off, acoustic signal on/off.

Flash and modelling power control.

«X» synchro jack socket 3,5 mm.

Socket for Plug-In remote control.

Auto dumping function. Automatic discharge of flash power

Central umbrella tube plus external fitting

Acoustic recharging signal

Mains cable

Synchro cord of 5m (jack 3.5mm plug)

Protective cover

Total compatibility with all Elinchrom accessories

Very fast recycling time

Very short flash duration

Technical data

 

 

300RX

600RX

1200RX

Flash power

 

J(Ws)

300

600

1200

Power supply

230V Version

V

all units 215-240

 

120V Version

V

all units 110-120

F-stop, 1m, 100 ISO, with reflector 48°

GN

64,1

90,1

128,1

Control range

 

J(Ws)

9-300

18-600

36-1200

Recycling time

230V Version

s

0,2-0,6

0,25-0,8

0,35-1,5

 

120V Version

s

0,25-1

0,3-1,6

0,35-2,8

Flash duration (t 0,5) 1/1

 

s

1/2850

1/2050

1/1450

(t 0,5) 1/32

 

s

1/1350

1/850

1/480

Modelling lamp

230V Version

W

250*/E27

250*/E27

300 GX 6,35

 

120V Version

W

150/BA15D

150/BA15D

250/BA15D

120V «Canada Version»

W

150/E27

150/E27

150/E27

Voltage across sync cable

 

V

5

5

5

Connected load A/VA

 

(W)

5/1150

6,3/1500

8/1840

 

Radio interference suppressiv CE-IEC 491 EN 60 555 - EN 61 000 - 4 - 2/3/4/5

Dimension length x diam.

 

cm

21x14

21x14

30x14

Weight

 

kg

2,15

2,45

3,45

* Optional alternative 300W/GX6.35

 

Tolerances and specifications conforming to IEC and CE standards.

12

Technical data subject to change without notice.

Image 13
Contents 120V 20726 Canada 120V 20725.1VS 20726.1VS Version 230VTable of contents Technical data subject to changeStyle 300RX 600RX 1200RX IntroductionFCC Class B Compliance Statement Disposal and recycling Declaration of conformityCE marking Notational ConventionsPower cable Safety noticeFlash Tubes and Modelling lamps TransportOperating instructions Before you startADF Control Panel Overview of controlsTroubleshooting Mains SwitchMains Supply Mains Fuse230V Modelling lamps and fuses Modelling Light120V Modelling lamps and fuses 120V «Canada Version» Modelling lamps and fusesPhotocell Digital Power DisplayAudible recharge signal Wireless Remote Control and Flash TriggeringSychronisation socket Open flash testTo replace the Flash tube Flash tube replacementTechnical data FeaturesElinchrom Accessories Elinca sa Guarantee