Elinchrom RX 300, RX 1200 Wireless Remote Control and Flash Triggering, Sychronisation socket

Page 11

Wireless Remote Control and Flash Triggering

All RX units, Style RX, Digital RX, Ranger RX are equipped with the Remote Plug, to connect the EL-Skyport Trigger and Remote System. With the EL- Skyport RX Trigger Set 19362,

the RX units can be triggered wireless, up to approximately 100 m distance. Apart from triggering, the Transmitter offers modelling lamp on /off settings and flash power control in 1/10th steps.

By using the EL- Skyport Computer Remote / Trigger Set 19361, all RX functions can be controlled and operated with a MAC° or Windows° computer.

19361

19362

For details of the most advanced wireless system please visit www.elinchrom.com > Products > RX Multi Remote > EL-Skyport.

Sychronisation socket

Sync

6

The standard socket 3.5 mm mini-jack (6).

 

 

 

N.B. Do not link ELINCHROM units by cable to other manufacturers sync outlets. ELINCHROM uses the low voltage (5 V) for security reasons.

Open flash "test"

Having pressed the touch pad to release a flash, the green «READY» light will appear again once the unit is recharged. If the green light does not appear the charge system could be defective.

Please contact and send to an authorized Elinchrom service.

Audible recharge signal

Select the function with the touch pad (8), the green indicator appears. Once recycled an acoustic signal indicates that the compact unit is ready.

Troubleshooting

Test and Ready

Beep

5

8

1.The mains switch (3) is ON ("I" position), but not light up:

Switch OFF the unit and change the mains fuse (2)

Use only time-lag fuse (16 AT), corresponding to the Style RX model

2.The switch (3) is lit, the open flash ready is lighting up but does not function.

The flashtube in the flashhead may be faulty (see page 11)

If replacing the flashtube does not solve the problem, the cause could be a component failure => please return the unit to an authorised Elinchrom service.

3.The ON/OFF switch (3) is lit but the open flash signal (6) is not lit

Temporary break for overheating, caused by fast flash sequences or ventilation slots obturated

Fan cooling defective => the unit turns off automatically and cannot be fired any more. After a break for cooling, the flash is ready again for operation.

If after several minutes of break for cooling the ready signal (6) is not lit, the cause could be a component failure. However, high voltage may remain on the capacitor circuits. => DO NOT ATTEMPT TO REPAIR THE UNIT. In this case please send the unit to an authorised Elincrom station.

10

Image 11
Contents 120V 20726 Canada 120V 20725.1VS 20726.1VS Version 230VTable of contents Technical data subject to changeFCC Class B Compliance Statement IntroductionStyle 300RX 600RX 1200RX Notational Conventions Declaration of conformityDisposal and recycling CE markingTransport Safety noticePower cable Flash Tubes and Modelling lampsOperating instructions Before you startADF Control Panel Overview of controlsMains Fuse Mains SwitchTroubleshooting Mains Supply120V «Canada Version» Modelling lamps and fuses Modelling Light230V Modelling lamps and fuses 120V Modelling lamps and fusesPhotocell Digital Power DisplayOpen flash test Wireless Remote Control and Flash TriggeringAudible recharge signal Sychronisation socketTo replace the Flash tube Flash tube replacementTechnical data FeaturesElinchrom Accessories Elinca sa Guarantee