accessible from the cover plate as illustrated in Figure 3-1. Figure 3-6 in this manual provides the wiring terminations for connections to the Sentry controller.

When the module is operated in conjunction with a Sentry controller, the alarms outputs in the module can both be set to “Sentry”, allowing the Sentry controller to manage alarm acknowledge and reset rather than the sensor module. The alarm relay outputs are triggered by the alarm values established in the module, and can be independent of the settings in the Sentry controller.

The Sentry configuration allows daisy chain installation using the Sentry multiplex capability, thus reducing costs by avoiding the requirement for wiring junction boxes. The connector card has two sets of

connections, allowing for a continuous run to the next module.

1.4.2MODBUS OPERATION

An RS-485 Modbus RTU serial interface allows direct connection to standard PLCs and DCSs. The Module Address Switch (section 3.5) allows the user to select up to 16 different Modbus addresses. Also, an additional 238 Modbus addresses (for a total of 254 different Modbus Addresses) are available via menu selection. Figure 3-6 in this manual provides the wiring terminations for Modbus connections. The 5100-XX-IT provides the additional terminal connectors to enable the user to connect In/Out terminations of a RS-485 connection.

1.4.3ANALOG OPERATION

The 4-20 mA interface allows direct connection to standard analog controllers or PLCs. The 5100-XX-IT 4- 20 mA connection can be wired as a Type 3 (3-wire) or Type 4 (4-wire) circuit as described by ANSI/ISA- 50.00.01-1975 Standard (see figure 3-5).

1.4.4REMOTE SENSOR AND DISPLAY (APPENDIX D)

The Remote Sensor and Display option (5394-52) can be used to remotely mount the sensor up to 100’ from the transmitter.

1.4.5REMOTE ALARM RESET (DIGITAL INPUT) (Figure 3-7)

An input is available for connection of remote alarm reset/acknowledge. Figure 3-4 provides the wiring termination for connecting the remote alarm reset. This only resets local alarms, not Sentry alarms. This input can be wired as supervised or non-supervised.

Note that when the Remote Alarm Reset is operated in a supervised mode that both the switch and resistor must be present as outlined in Figure 3-7.

1.4.6OPTIONAL INTEGRAL RELAYS

The optional relays are integral to the gas sensor module and are rated as SPDT, 250VAC, 8 Amps for the High Alarm and Low Alarm relays and SPDT, 250 VAC, 2 Amp for the Trouble relay.

If the gas sensor module is provided with the optional relays, it will include Terminal P4 on the interface board (Figure 3-2). Relay output connections are on P4.

MECHANICAL

The sensor module of comprised of the following three primary components:

1.4.7ENCLOSURE

Standard on the 5100-XX-IT is an explosion-proof, rain-tight cast aluminum electrical housing (Figure 1-1) with three ¾” FNPT conduit hubs. The 5100-XX-IT-SS (Figure 1-2) has a 316 Stainless Steel enclosure. Both enclosure covers have a viewing window. The design of the enclosure allows 3-way mounting choices as shown in figure 1-3.

Page: 2

Image 6
Contents IT Series Applicability & EffectivityContents This page Intentionally Left BlankTable of Contents Appendices Product Description Mechanical Page Transmitter Electronics Introduction IT Modules General This page Intentionally Left Blank Installation Enclosure Installation Establish the module address according to section Sensor Module Address Switch Positions Transmitter Face PlatePage 20mA Circuit Types 20mA Circuit Type Connections for 5100-XX-IT Page Wiring Connections for Remote Alarm Reset This page Intentionally Left Blank Operation Mode EnterIT Module Menu Switch Locations Key M Key E Key /\Key Function Display Description Reference Operation Display ValuesModel 5100-XX-IT Toxic Gas Sensor Module Relays Set Point Adjustment Example 3A Set-Up ConfigurationRS-485 Adjustment Example Gas Range Adjustment ExampleMA Adjustment Example 3B Set-Up ConfigurationMaintenance Menu This page Intentionally Left Blank Calibration Model 5358-01 Calibration AdapterModel Gas Flow Period Sub-RoutinesService XxxxxxxTransmitter Replacement Power cycle the unit Recalibrate the sensor Appendix a Specifications AppendicesModel 5100-XX-IT Toxic Gas Sensor Module Ordering InformationAppendix B Model Numbers & Parts List Sensor ModuleAppendix C Limited Warranty Appendix D Remote SENSOR/DISPLAY Drawing Appendix E Modbus Memory MAP Read Register Table DescriptionComments

5100-03-IT, 5100-05-IT, 5100-06-IT, T12020, 5100-04-IT specifications

Sierra Monitor Corporation is renowned for its commitment to providing cutting-edge technology solutions for industrial monitoring and control systems. Among its notable products, the Sierra Monitor Corporation 5100 series, which includes models 5100-06-IT, 5100-05-IT, 5100-04-IT, and 5100-03-IT, stands out for its robust design and advanced features tailored for diverse applications in industrial environments. Additionally, the T12020 model complements this series, offering unique functionalities.

The 5100 series is primarily designed for gas detection and monitoring, equipped with advanced sensors capable of identifying a wide array of gases, including combustible, toxic, and refrigerant gases. These models utilize state-of-the-art technology, including electrochemical and infrared sensors, ensuring high sensitivity and accuracy in detecting hazardous gases. This is crucial for maintaining safety in industrial settings where exposure to harmful gases can pose significant risks to personnel and equipment.

One of the main features of the 5100 series is its versatility. Each model is equipped with customizable settings, allowing users to configure alarm levels and response options to meet specific operational needs. This flexibility is essential in applications ranging from petrochemical plants to wastewater treatment facilities. The intuitive interface provides easy navigation and management, enabling users to monitor gas levels in real-time.

The 5100 series incorporates advanced communication technologies, including Modbus, RS-485, and Ethernet protocols. This facilitates seamless integration into existing control systems and enhances remote monitoring capabilities. Users can access real-time data and alarm notifications from any web-enabled device, ensuring prompt responses to potential gas leaks.

In addition to the 5100 series, the T12020 model serves as a robust solution for environmental and indoor air quality monitoring. It features similar advanced sensor technologies and offers additional applications, including HVAC control and indoor space safety management. This model provides essential data for building management systems, contributing to energy efficiency and improved air quality for occupants.

Overall, the Sierra Monitor Corporation’s 5100 series and the T12020 model exemplify the company’s dedication to innovation and safety. With a focus on reliability, precision, and user-friendly design, these products set a high standard in the field of gas detection and industrial monitoring, making a significant impact on enhancing workplace safety and operational efficiency.