3. Installation Locations

Locations To Avoid

IMPORTANT: Improper location can affect the sensitive electronic com- ponents in this alarm. To avoid causing damage to the unit, to provide optimum performance, and to prevent unnecessary nuisance alarms:

Do not install in kitchens, garages or furnace rooms that may expose the sensor to substances that could damage or contaminate it.

Do not install in areas where the temperature is colder than 0°C or hotter than 40°C such as crawl spaces, attics, porches and garages.

Do not install within 1.5m. of heating or cooking appliances. (Kidde recommends 3m. to prevent nuisance alarms).

Do not install near vents, flues, chimneys or any forced/unforced air ventilation openings.

Do not install near ceiling fans, doors, windows or areas directly exposed to the weather.

Do not install in dead air spaces, such as peaks of vaulted ceilings or gabled roofs, where CO may not reach the sensor in time to provide early warning.

Do not install this unit near deep-cell large batteries. Large batteries have emissions that can cause the alarm to perform at less than optimum performance.

Do not obstruct the vents located on the alarm. Do not place the alarm where drapes, furniture or other objects block the flow of air to the vents.

Image 11
Contents Models C3010 and C3010-D Carbon Monoxide AlarmWhat to do When the Alarm Sounds Important Warning Statements WelcomeContents of This User’s Guide Information About Carbon Monoxide Low Levels High LevelsMid Levels Conditions That Can Produce Carbon Monoxide Information About Carbon Monoxide Model C3010 Product Features and SpecificationsInstallation Locations Locations To Avoid Cover is not Removable Installation InstructionsImportant Labels Provided Alarm is now activatedMounting Operating and Alarm Characteristics Model C3010 Operating CharacteristicsGood batteries Peak Level Memory model C3010-D only Peak Level Memory ResetTesting Alarm CharacteristicsMaintenance Carbon Monoxide Alarm IndicatorPlacing unit into shut down mode at end of its useful life TEN Year Limited Warranty