6.Model
Peak Level Memory (model C3010-D only)
When the Peak Level button is pressed and held, the display shows the highest CO reading taken by the CO alarm since
its last reset or power up. In this example 120 PPM was the maximum amount of CO recorded since the unit was last reset.
The Peak Level display feature will display levels between
device is exposed to these levels. The Peak Level feature is helpful in identifying if you have had a CO reading since resetting the alarm.
Concentrations of CO between 1 and 30 PPM can often occur in normal, everyday conditions. Concentrations of CO below 30 PPM may be an indication of a transient condition that may appear today and never reappear. Some CO conditions may start out as low level leaks but could develop into CO concentrations that may become harmful.
If this happens, the CO alarm will detect the dangerous level and alarm, notifying you and others of the conditions. DO NOT ignore high concentration readings above 30 PPM or a CO alarming device that is in alarm.
Peak Level Memory Reset
Press the Peak Level button; with the button still pressed, press the Test/ Reset button for two seconds then release the Test followed by the Peak Level buttons. The number on the display will turn to “0”, the memory will be cleared and the alarm will begin monitoring for CO.