Kidde KN-COB-B-LPM, KN-COPP-B-LPM (with Digital Display) manual Installation Locations

Page 6
Recommended Locations

2. Product Features and Specifications

Temperature:

Operating Range: 40°F (4.4°C) to 100°F (37.8°C)

Humidity:

Operating range: 10-95% non-condensing

Audible Alarm:

85+ dB at 10’ @ 3.4±0.5 KHz pulsing alarm

Sensor:

Electrochemical

Power:

3-AA Batteries

Accuracy of Digital Display: (Model KN-COPP-B-LPM Only)

30-999 PPM +/-30% when measured in conditions of 80° F (+/- 10° F), atmospheric pressure +/- 10% and 40% +/- 3% relative humidity. Display readings may vary slightly depending on changes in the ambient condition (temperature, humidity) and the condition of the sensor.

Alarm Response Times:

70 PPM = 60-240 min., 150 PPM = 10-50 min., 400 PPM = 4-15 min.

3. Installation Locations

Recommended Installation Locations

 

CO alarms should be mounted in

 

 

or near bedrooms and living areas.

DINING

KITCHEN BEDROOM BEDROOM

It is recommended that you install

 

 

a Kidde CO alarm on each level of

 

your home.

LIVING ROOM

 

3. Installation Locations

Locations To Avoid

IMPORTANT: Improper location can affect the sensitive electronic com- ponents in this alarm. To avoid causing damage to the unit, to provide optimum performance, and to prevent unnecessary nuisance alarms:

Do not install in kitchens, garages or furnace rooms that may expose the sensor to substances that could damage or contaminate it.

Do not install in areas where the temperature is colder than 40°F (4.4°C) or hotter than 100°F (37.8°C) such as crawl spaces, attics, porches and garages.

Do not install within 5 ft. of heating or cooking appliances. (Kidde recommends 15 ft. to prevent nuisance alarms).

Do not install near vents, flues, chimneys or any forced/unforced air ventilation openings.

Do not install near ceiling fans, doors, windows or areas directly exposed to the weather.

Do not install in dead air spaces, such as peaks of vaulted ceilings or gabled roofs, where CO may not reach the sensor in time to provide early warning.

Do not install this unit near deep-cell large batteries. Large batteries have emissions that can cause the alarm to perform at less than optimum performance.

Do not obstruct the vents located on the alarm. Do not place the alarm where drapes, furniture or other objects block the flow of air to the vents.

When choosing your installation locations, make sure you can hear the alarm from all sleeping areas. If

BEDROOM

you install only one CO alarm in your home, install it near bedrooms, not in the basement or furnace room.

When wall mounting, place out of reach of children. Under no circumstances should children be allowed to handle the CO alarm.

Placing the alarm at eye level allows for optimum monitoring of the digital display.

Image 6
Contents Carbon Monoxide Alarm Models KN-COB-B-LPMWelcome Important Warning StatementsContents of This User’s Guide Information About Carbon MonoxideLow Levels High LevelsMid Levels Possible Sources of Carbon MonoxideModel KN-COB-B-LPM Installation Locations Mounting Installation InstructionsBattery Installation and Replacement Important Labels ProvidedModel KN-COB-B-LPM Operating Characteristics Operating and Alarm CharacteristicsAlarm Characteristics MaintenanceFive Year Limited Warranty