Kidde manual Model KN-COB-B-LPM Operating Characteristics, Operating and Alarm Characteristics

Page 8

5. Model KN-COB-B-LPM Operating Characteristics

Whenever the alarm is operating, the green Power LED flashes every 30 seconds to indicate the unit is monitoring for CO. If the alarm senses dangerous levels of CO, the red Alarm LED will flash and the alarm will emit an audible alarm pattern.

Operating and Alarm Characteristics

Function

LED Display

Alarm Sound

Unit Status

Recommendation

 

 

 

 

 

 

Normal

Green LED

None

Normal DC

None

Operation

flashes every 30

 

operation (sensing

 

 

seconds

 

no CO) and with

 

 

 

 

good batteries

 

 

 

 

 

 

 

Carbon

Red LED flashes

4 quick beeps,

Alarm condition.

Refer to “What to

monoxide

with beeps.

5 seconds

Dangerous con-

do When the Alarm

alarm

 

silence,

centrations of CO

Sounds” (inside front

 

 

repeating

detected

cover)

 

 

 

 

 

 

Low

Red LED flashes

One quick

Batteries need to be

Replace all three AA

battery

every 60 seconds

beep every

replaced

batteries

 

 

60 seconds

 

 

 

 

 

 

 

 

 

Error /

Red LED flashes

One quick

Unit is in error

Replace battery.

service

every 30 seconds

beep every

condition

If condition continues,

alarm

 

30 seconds

 

 

unit has malfunc-

 

 

 

 

 

tioned. Replace

Error

Red LED

Constant

Very low battery or

immediately. Unit will

 

constantly on

alarm

unit malfunction

not respond to CO

 

 

 

 

 

Normal

Red LED flashes

4 quick beeps,

Normal operation

CO not detected.

Test/Reset

with beeps.

5 seconds

when Test/Reset

Alarm for test pur-

function

 

silence,

button is pressed

poses only

 

 

repeated once

 

 

 

 

 

 

 

 

End of

Red LED flashes

Two quick

End of unit life

Replace unit imme-

unit life

two times

beeps every

 

 

diately. Unit will not

indicator

every 30 seconds

30 seconds

 

 

respond to to CO

 

 

 

 

 

 

6.Model KN-COPP-B-LPM (with digital display)

Operating Characteristics

When the unit is first powered up, the green Operate LED flashes once every 30 seconds and the digital display will show three “eights”

indicating the alarm is in the start-up mode. The three “eights” will remain for approximately 30 seconds. Then, the alarm will display “0” and begin monitoring the air for CO and will continue to do so as long as it receives power.

This alarm will display a “0” if CO concentrations between 0 and 30 PPM have been detected within the last 15 seconds.

6.Model KN-COPP-B-LPM (with digital display)

Operating Characteristics

The following table illustrates the possible digital displays, describes the audible alarm patterns, and the recommended actions to take.

Operating and Alarm Characteristics

LCD Display Shows

Alarm Sound

Unit Status

Recommendation

 

 

 

 

 

 

 

A steady display of

4 quick beeps,

Alarm condition.

Refer to “What to

 

 

CO concentration

5 secs. silence,

Dangerous

do When the Alarm

 

from 30-999. Red

repeating

concentrations of

Sounds” (inside front

LED flashes with beep

 

CO detected

cover)

 

 

 

 

 

 

 

Brief “888” for

None

Self test when first

None – CO has

 

 

approximately 30

 

powered up

not been detected.

 

seconds

 

 

 

Numbers shown for

 

 

 

 

 

test purpose only

 

 

 

 

 

 

 

A random number

4 quick beeps,

Test/Reset button is

None – CO has

 

 

is displayed –

5 seconds

pressed

not been detected.

 

between approxi-

silence,

 

 

Numbers shown for

mately 150 and 300

repeated once

 

 

test purpose only

 

 

 

 

 

 

Steady “0” displayed, None

Normal DC

None

 

 

dot flashing every 5

 

operation with

 

 

seconds, Green LED

 

good batteries

 

 

flashes every 30 secs.

 

(sensing no CO)

 

 

 

 

 

 

 

 

“Lb” flashes alter-

One quick beep

Batteries need to

Replace all three AA

 

 

nately with any

every 60 seconds

be replaced

batteries immediately

 

number, Red LED

 

 

 

 

flashes every 60 seconds.

 

 

 

 

 

 

 

 

 

 

 

“Err” displayed

One quick beep

Unit is Error con-

Replace batteries.

 

 

 

every 30 seconds

dition

If “Err” (or blank

 

 

 

 

 

display) continues,

 

 

 

 

 

unit has malfunc-

 

 

 

 

 

tioned. Replace

 

 

 

 

 

immediately. Unit will

 

Display is blank

Constant alarm

Unit malfunction

 

not respond CO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number from

None

Peak Level Memory

Refer to following

 

 

11-999 displayed.

 

activated. Highest

section for informa-

 

 

 

concentration of

tion regarding Peak

 

 

 

CO detected is

Level Memory

 

 

 

displayed

 

 

 

 

 

 

 

“End” displayed.

Two quick

End of unit life

Replace unit imme-

 

 

Red LED flashes

beeps every

 

 

diately. Unit will not

 

two times

30 seconds

 

 

respond to CO.

 

every 30 seconds

 

 

 

 

The problems listed above are under normal operating conditions. Other “Err” conditions could exist. If you should have any questions regarding display conditions, call our Consumer Hotline.

Image 8
Contents Carbon Monoxide Alarm Models KN-COB-B-LPMWelcome Important Warning StatementsContents of This User’s Guide Information About Carbon MonoxideHigh Levels Mid LevelsLow Levels Possible Sources of Carbon MonoxideModel KN-COB-B-LPM Installation Locations Installation Instructions Battery Installation and ReplacementMounting Important Labels ProvidedModel KN-COB-B-LPM Operating Characteristics Operating and Alarm CharacteristicsAlarm Characteristics MaintenanceFive Year Limited Warranty