Kidde KN-COPF-I manual Alarm Characteristics, Mounting, Important Labels Provided

Page 8

4. Installation Instructions

Mounting

After selecting the proper location for your CO alarm and wiring the AC Quick- Connector harness, plug the AC Quick- Connector into the mating connector in the back of the alarm. Be sure the con- nectors snap together securely.

Push the excess wire back into the elec-

trical box.

Install the alarm in the electrical box using the four screws provided.

Turn on the AC power. The green AC Power On Indicator should be lit when the alarm is operating from AC power.

The rechargeable battery is turned on automatically when AC power is sup- plied.

NOTE: LOW BATTERY WARNING IS DISABLED FOR 24 HOURS AFTER ALARM IS FIRST POWERED ON TO ALLOW THE BATTERY TIME TO CHARGE.

Important Labels Provided

Two labels have been provided that have important information on what to do in case of an alarm. Add the phone number of your emergency service provider in the space provided. Place one label next to the alarm after it is mounted, and one label near a fresh air source such as a door or window.

5. Alarm Characteristics

Carbon Monoxide Alarm Indicator

When the alarm senses a dangerous level of CO, the unit will emit a loud alarm pattern. The alarm pattern is four (4) quick beeps followed by five (5) seconds of silence. This cycle repeats as long as a dangerous CO conditions exist. The red Alarm LED will flash the same pattern (and the PPM will be displayed on alarms with digital displays). The amber LED (Initiating Alarm) of the unit(s) which has (have) detected the CO, will light for the duration of the alarm.

WARNING: When powered by battery backup only, after four minutes, the alarm will sound and flash only once every minute, until the alarm is reset or the CO is eliminated.

If this unit is interconnected with other Kidde CO alarms, the amber LED (Initiating Alarm) of the unit which has detected the CO, will light for the duration of the alarm. The other interconnected CO alarms will also alarm to warn you that CO was detected but the amber LED will NOT light.

If interconnected to other Kidde alarms and the backup battery (if equipped) is low or missing, or if the unit malfunctions, it will display other readings (and alarm differently) to alert you of specific conditions. Please familiarize yourself, and other family members, to the difference between a CO reading and and indication signifying a problem with the unit itself.

WARNING: If at any time you test the alarm and it does not perform as described, have it replaced immediately.

Smoke Alarm Indicator (interconnected with CO Alarms)

When an interconnected Kidde smoke alarm detects smoke, the Kidde CO alarm will sound a smoke/fire alarm pattern of three (3) long beeps, followed by one (1) second of silence. This cycle repeats as long as smoke signal persists to alert you of the condition. The word “Fire” will scroll across the digital display. If this happens, leave the premises imme- diately by your escape plan and call your local fire department.

WARNING: This unit is not a smoke alarm and will not detect smoke or fire. It will only alarm for smoke/fire if it receives a signal from an inter- connected Kidde smoke alarm.

NOTE: A smoke/fire alarm will override a CO alarm condition.

Image 8
Contents Carbon Monoxide Alarm Model KN-COPF-iWelcome Important Warning StatementsContents of This User’s Guide Information About Carbon MonoxideCarbon Monoxide PPM Levels High LevelsMid Levels Low LevelsProduct Features and Specifications Model KN-COPF-iInstallation Locations Installation Instructions InterconnectingWiring Wires on the AC Quick-Connector Alarm HarnessAlarm Characteristics Carbon Monoxide Alarm IndicatorSmoke Alarm Indicator interconnected with CO Alarms MountingModel KN-COPF-i Operating Characteristics Operating and Alarm CharacteristicsPeak Level Memory Reset Peak Level MemoryMaintenance TestingBattery Backup Alarm RemovalSeven Year Limited Warranty

KN-COPF-I specifications

The Kidde KN-COPF-I is a state-of-the-art carbon monoxide and propane gas detector designed to ensure the safety of homes and commercial spaces. With an emphasis on user-friendly features and advanced technology, this model stands out as a reliable solution for detecting harmful gases that can pose health risks to occupants.

One of the primary features of the Kidde KN-COPF-I is its ability to detect both carbon monoxide and propane gas. Carbon monoxide is a colorless, odorless gas that can be lethal if levels build up within an enclosed space. The KN-COPF-I is equipped with a highly sensitive electrochemical sensor specifically designed to identify even low levels of carbon monoxide. Additionally, the unit detects propane gas leaks, making it suitable for homes that use propane for heating or cooking, further enhancing its versatility in the realm of safety devices.

The KN-COPF-I features a digital display that provides continuous monitoring of both CO and propane levels in real-time. This digital interface allows users to easily keep track of their environmental safety, as it displays the current levels and alerts when they reach dangerous thresholds. The device also includes a peak level memory function, which records the highest concentration of carbon monoxide detected, allowing users to review previous incidents.

Installation and usability are key considerations in the design of the Kidde KN-COPF-I. The unit comes with a mounting bracket, making it simple to install on walls or ceilings in strategic locations throughout the home. It is powered by an AC power source, ensuring continuous operation, while a battery backup provides additional security in the event of a power outage.

Another significant characteristic of the Kidde KN-COPF-I is its safety alarms, which include a loud 85-decibel warning signal for carbon monoxide detection, as well as visual alerts for propane detection. These alarms are crucial for alerting occupants promptly, allowing them to take necessary actions to evacuate or respond to hazards before they escalate.

For added peace of mind, the Kidde KN-COPF-I also features a test/reset button, which allows users to routinely check the functionality of the device and ensure that it operates correctly. This ensures that the detector remains reliable over time.

In conclusion, the Kidde KN-COPF-I combines advanced detection technologies with intuitive features to provide comprehensive protection against carbon monoxide and propane gas. Its digital display, dual detection capability, and easy installation make it an essential device for any safety-conscious household.