IRIS P522 manual S506 Viewing Head

Page 19

IRIS MODEL P522 APPLICATION MANUAL

ing head male receptacle has an internal tab that grounds this connection to the viewing head housing. The terminal marked GND connects to the chassis ground of the P522. This ground is made through the etch on the rear side of the PC board to the metal base.

It is important that the AC power be a grounded source (i.e., GND going to plant ground – refer to section POWER SUPPLY). Interference problems can occur if the power supply chassis and the P522 chassis are at a different ground potential than the viewing head housing, which will be at a ground potential associated with the burner front. In these situations, the IRIS flame monitor effectively sup- plies a plant ground between the burner front and the panel enclosure. If there is a large potential dif- ference between these points, considerable current can flow through the viewing head cable, which can, in turn, damage the P522 signal processor or the as- sociated power supply.

If there is a voltage difference between the viewing head and the sight pipe, then you should use a non- conductive, one-inch plastic nipple between the sight pipe and the viewing head mounting flange. This voltage difference can be easily measured by dis- connecting the viewing head from the mounting flange so that there is no continuity between the view- ing head and the boiler front.

Note: Use a battery operated multimeter on a high voltage AC range for making this measurement.

This measurement should be made under various conditions (i.e., during the sequencing of the igniter and burner).

In addition to using the isolated nipple for the view- ing head flange, you must use a nonconductive rub- ber or plastic hose for the purge air (there is a 1/2- inch NPT pipe thread on the flange). This will pre- vent the current from flowing through the IRIS cable (power ground) back to the P522.

Another source of interference is from high-voltage spark igniters. A high voltage of 6 KV or more is usually supplied by a step-up autotransformer and, not being isolated from the power line, it can cause

interference, particularly if there are grounding prob- lems. The usual problem occurs when the trans- former is energized, resulting in a bogus flame sig- nal. The problem is not caused by the spark across the gap, but by radiation from the high-voltage wir- ing feeding the spark gap. It is the secondary wiring of the transformer (high-voltage AC) that causes this interference – both the insulated wire to the spark gap, as well as the ground return. This circuit loop acts like a giant antenna. Also, this type of trans- former can cause a ground problem because it is an autotransformer, and because it is not isolated from the power line. The high-voltage current to the ig- niter must return to the transformer through the plant ground, which is the conductive metal of the plant.

The solution to these problems is to locate the igni- tion transformer as close as possible to the igniter, and away from the P522 and power supply. The shorter the secondary wire run, the better. Also, the ground return path should be examined. Is the ig- niter properly grounded, and is this a good plant ground? Plus, you should examine the grounding of the transformer case: we recommend that there be a good plant ground on the transformer case, and that the transformer be enclosed in a metal enclosure that is also grounded.

Usually, there are no straightforward solutions to electrical interference problems; each will have its own unique causes. However, there are certain pre- cautions or guidelines that you should be aware of. The first thing to check is the grounding of the in- stallation. Make sure the AC power feeding the sys- tem is grounded, and that the ground is a bona fide plant ground. And, make sure the proper cable is being used for the viewing head.

Note: Do not use cables that employ foil type shields (aluminum-polyester). We recommend you use the standard IRIS cable that has a braided shield.

S506 VIEWING HEAD

The S506 viewing head employs a UV tube that has a spectral response of 185-260nm. It is an inherent pulsing device (i.e., the power supply has been de- signed so that the tube emits pulses when UV radia-

Page 19

Image 19
Contents Flame Monitoring System Table of Contents Figure Index Iris Model P522 Wiring and InstallationWiring to the PLUG-IN Terminals Term Description Wiring of Viewing HeadTYP Power Supply Factory Stocked Power Supplies Redundant Power Supplies1-9, 10 Pulses Counted During Powering UP the P522Approvals SELF-CHECKING FunctionChanging SET Points SET PointsChecking Function Time F.F.R.T Flame Failure ResponseSighting of the Viewing Head Installation of Viewing HeadMultiple Viewing Heads Multiburner RequirementsMounting of Sight Pipe Installing the Viewing HeadSelecting the Pipe Determining Sight Pipe Size Mounting HoleSighting Adjustment Setup and AdjustmentProcedures Initial SetupFor Flicker Type Viewing Adjusting SET PointsMultiburner Requirements Grounding Noise InterferenceS506 Viewing Head S509 Viewing Head S506 SELF-CHECKING Viewing HeadS512 Viewing Head S511 Viewing HeadIris Model P522 Application Manual Orificing Signal SourcesViewing Head Angle of View Viewing Head Angle View Distance and Diameter Application of Iris Viewing HeadsMonitor Using a PLC with Iris FlameApplication of P522 GAS LOW no X Burners GAS HYDROGEN, Propane and Natural GASPulverized Coal OIL Heavy OIL air & steam atomBasic Burner Start Circuit Basic Burner Start Circuit Modbus Communication Module Communications0X or Discrete Registers Setting AddressesTechnical Help Outputs Iris Model P522 Application Manual ElectricalEnvironmental OpticalModel P522 Front Panel Model P522 Side View IR Viewing Head Location Opposed Fired Viewing Head Sighting 18, 21, 22 IndexIris Model P522 Application Manual

P522 specifications

The IRIS P522 is a highly advanced smart device characterized by its cutting-edge features, technologies, and remarkable performance capabilities. Designed for seamless integration into both personal and professional environments, the P522 stands out as a versatile tool for various applications, ranging from productivity enhancement to entertainment.

One of the main features of the IRIS P522 is its state-of-the-art display technology. The device sports a high-resolution touchscreen that provides vibrant colors and sharp images, ensuring a remarkable visual experience. This impressive display is paired with an ultra-responsive multi-touch interface, allowing users to interact effortlessly with the device, facilitating increased efficiency in tasks such as data entry, navigation, and media consumption.

The performance of the IRIS P522 is powered by a robust processor and ample RAM, enabling it to handle multitasking with ease. This ensures that users can run multiple applications simultaneously without experiencing lags or slowdowns. Additionally, the device incorporates advanced cooling technologies, which help maintain optimal operating temperatures even during intensive use, ensuring reliability over extended periods.

Connectivity is another significant aspect of the IRIS P522. Equipped with the latest wireless technologies, including Wi-Fi 6 and Bluetooth 5.0, the device allows for lightning-fast data transfer rates and seamless connections to a variety of accessories. This makes it an ideal choice for professionals who require constant communication and quick access to cloud-based resources.

Security features are paramount in today's digital landscape, and the IRIS P522 does not disappoint. It includes biometric authentication options such as fingerprint recognition and facial recognition, providing users with a secure way to access their device and data. This focus on security is further reinforced by regular software updates that ensure protection against the latest threats.

Battery life is another highlight of the IRIS P522, with an energy-efficient design that offers extended usage without frequent recharges. This is particularly beneficial for users on the go, as it enables prolonged productivity without being tethered to a power supply.

In conclusion, the IRIS P522 is a remarkable device that harmoniously blends advanced features, powerful technology, and user-centric design. With its stunning display, high performance, effortless connectivity, robust security measures, and extended battery life, the P522 caters to the needs of users in various contexts, making it an indispensable addition to modern digital life.