IRIS P522 manual Index, 18, 21, 22

Page 39

IRIS MODEL P522 APPLICATION MANUAL

INDEX

4-20mA

 

 

 

 

 

6, 12

A

 

 

 

 

 

 

 

 

AGC

 

18, 21, 22, 23,

24, 25

angle of view

 

 

 

 

 

24, 15

aperture

 

 

 

 

 

 

22

B

 

 

 

 

 

 

 

 

background flame

 

 

 

 

 

16, 21

battery

 

 

 

5, 9, 10,

19, 26

baud rate

 

 

 

 

 

31, 32

brightness

 

 

 

 

 

21, 22

C

 

 

 

 

 

 

 

 

cable

 

 

 

 

 

5, 6, 8

channel select

 

 

 

 

 

10, 32

com port

 

 

 

 

 

 

6

communication port

 

 

 

 

 

 

12

current output

 

 

 

 

 

 

13

D

 

 

 

 

 

 

 

 

disable

 

 

 

 

 

 

32

E

 

 

 

 

 

 

 

 

EEPROM

 

 

 

 

 

 

10

enclosure

 

 

 

 

 

 

19

F

 

 

 

 

 

 

 

 

F.F.R.T

 

 

 

 

 

12, 16

fail-safe

 

 

 

 

 

26, 31

FFRT

 

 

 

 

 

 

32

FGR

 

 

 

 

 

25, 26

fiber optic

 

 

 

 

 

 

13

filter

 

 

14, 17, 20, 24, 32

filter switch

 

 

 

14, 17, 20, 21

flame relay

 

 

5, 10, 14, 20, 26, 29

flicker

13, 14, 16, 17, 21, 22, 23, 24, 25

fuses

 

 

 

 

 

5, 9

G

 

 

 

 

 

 

 

 

grounding

 

 

 

 

 

18, 19

germanium photodiode

.............................................

 

 

 

 

21

H

 

 

 

 

 

 

 

 

hydrogen

 

 

 

 

 

 

27

I

 

 

 

 

 

 

 

 

incandescent

 

 

20, 21, 22, 23, 24

information

 

 

 

 

 

 

31

infrared

 

 

 

 

 

16, 26

interference

 

 

 

 

 

18, 19

IRIS cable

 

 

 

 

 

8, 19

L

 

 

 

 

 

 

 

 

lead sulfide (PbS)

 

 

 

 

 

 

20

lens

13,

15,

20,

22,

23,

24,

25

lockout

10,

11,

15, 18,

20, 32

lockout condition

 

 

 

 

10, 11

low NOx

 

 

 

16, 25, 26

M

 

 

 

 

 

 

 

memory

 

 

 

 

10, 11

modbus communication

 

 

 

 

 

31

N

 

 

 

 

 

 

 

natural gas

14, 17, 20, 21, 23, 25

noise

 

 

 

 

12, 18

O

 

 

 

 

 

 

 

oil

14,

15,

16,

20,

22,

23,

25

P

 

 

 

 

 

 

 

PbS channel

 

 

 

17, 21, 22

PLC

 

 

26, 29, 31, 32

power failure

 

 

 

 

 

10

pressure

 

 

 

13, 15, 26

propane

 

 

 

20, 21, 23

pulverized coal

 

 

14, 20, 23, 25

pulses counted

 

 

 

 

10, 15

R

 

 

 

 

 

 

 

relay contacts

 

 

 

 

5, 29

remote meter

 

 

 

6, 9, 12

reset

10, 11, 13, 18, 29, 31,

32

registers map

 

 

 

 

 

32

RS-232 to RS-422

 

 

 

 

6, 32

S

 

 

 

 

 

 

 

safe-start-check

 

 

 

 

 

29

saturation of the photodetector

.................................

 

 

 

22

self-check

 

 

 

6, 10, 11

self-check relay

 

 

 

 

 

11

serial communication

 

 

 

6, 9, 10, 12

Si channel

17, 20, 21, 22, 23, 25

silicon (Si)

 

 

 

 

 

20

T

 

 

 

 

 

 

 

temperature

 

 

13, 32, 22, 26

technical information

 

 

 

 

33, 34

time delay

 

12, 16, 26, 29, 32

time delay on

 

 

 

 

16, 32

U

 

 

 

 

 

 

 

ultraviolet (UV) tube

 

 

 

10,19,20,23

V

 

 

 

 

 

 

 

visible zone

 

 

 

 

 

20

viewing heads, multiple

 

 

 

 

14, 29

W

 

 

 

 

 

 

 

wiring viewing head plug

 

 

 

 

6, 8

wiring viewing head to P522

 

 

 

 

5

Rev April 2000

Page 39

Image 39
Contents Flame Monitoring System Table of Contents Figure Index Iris Model P522 Wiring and InstallationWiring to the PLUG-IN Terminals Term Description Wiring of Viewing HeadTYP Power Supply Factory Stocked Power Supplies Redundant Power Supplies1-9, 10 Pulses Counted During Powering UP the P522Approvals SELF-CHECKING FunctionSET Points Changing SET PointsChecking Function Time F.F.R.T Flame Failure ResponseSighting of the Viewing Head Installation of Viewing HeadMultiple Viewing Heads Multiburner RequirementsMounting of Sight Pipe Installing the Viewing HeadSelecting the Pipe Determining Sight Pipe Size Mounting HoleSighting Adjustment Setup and AdjustmentProcedures Initial SetupAdjusting SET Points For Flicker Type ViewingMultiburner Requirements Grounding Noise InterferenceS506 Viewing Head S509 Viewing Head S506 SELF-CHECKING Viewing HeadS512 Viewing Head S511 Viewing HeadIris Model P522 Application Manual Orificing Signal SourcesViewing Head Angle of View Viewing Head Angle View Distance and Diameter Application of Iris Viewing HeadsUsing a PLC with Iris Flame MonitorApplication of P522 GAS LOW no X Burners GAS HYDROGEN, Propane and Natural GASPulverized Coal OIL Heavy OIL air & steam atomBasic Burner Start Circuit Basic Burner Start Circuit Modbus Communication Module Communications0X or Discrete Registers Setting AddressesTechnical Help Outputs Iris Model P522 Application Manual ElectricalEnvironmental OpticalModel P522 Front Panel Model P522 Side View IR Viewing Head Location Opposed Fired Viewing Head Sighting 18, 21, 22 IndexIris Model P522 Application Manual

P522 specifications

The IRIS P522 is a highly advanced smart device characterized by its cutting-edge features, technologies, and remarkable performance capabilities. Designed for seamless integration into both personal and professional environments, the P522 stands out as a versatile tool for various applications, ranging from productivity enhancement to entertainment.

One of the main features of the IRIS P522 is its state-of-the-art display technology. The device sports a high-resolution touchscreen that provides vibrant colors and sharp images, ensuring a remarkable visual experience. This impressive display is paired with an ultra-responsive multi-touch interface, allowing users to interact effortlessly with the device, facilitating increased efficiency in tasks such as data entry, navigation, and media consumption.

The performance of the IRIS P522 is powered by a robust processor and ample RAM, enabling it to handle multitasking with ease. This ensures that users can run multiple applications simultaneously without experiencing lags or slowdowns. Additionally, the device incorporates advanced cooling technologies, which help maintain optimal operating temperatures even during intensive use, ensuring reliability over extended periods.

Connectivity is another significant aspect of the IRIS P522. Equipped with the latest wireless technologies, including Wi-Fi 6 and Bluetooth 5.0, the device allows for lightning-fast data transfer rates and seamless connections to a variety of accessories. This makes it an ideal choice for professionals who require constant communication and quick access to cloud-based resources.

Security features are paramount in today's digital landscape, and the IRIS P522 does not disappoint. It includes biometric authentication options such as fingerprint recognition and facial recognition, providing users with a secure way to access their device and data. This focus on security is further reinforced by regular software updates that ensure protection against the latest threats.

Battery life is another highlight of the IRIS P522, with an energy-efficient design that offers extended usage without frequent recharges. This is particularly beneficial for users on the go, as it enables prolonged productivity without being tethered to a power supply.

In conclusion, the IRIS P522 is a remarkable device that harmoniously blends advanced features, powerful technology, and user-centric design. With its stunning display, high performance, effortless connectivity, robust security measures, and extended battery life, the P522 caters to the needs of users in various contexts, making it an indispensable addition to modern digital life.