MARKING
All units have a rating label which carries the following important information:-
Model type: | GAS DETECTOR TYPE ED810 | |
Input voltage: | 12Vdc/24Vdc | (delete as appropriate) |
Vmax in; | Um: 250V |
|
Code: | [EEx ia] II C |
|
Certificate no. | Baseefa03ATEX0507 |
|
Epsilon x, |
|
|
gas group | II (1) G |
|
and category: |
|
|
CE marking, |
|
|
Notified body | 1180 |
|
number: |
|
|
Serial no. |
| (serial number must be entered here) |
Year of construction: |
| (year of manufacture must be entered here) |
GENERAL
The ED810 is a fixed installation gas detection system which can detect a wide range of flammable and toxic gases dependent upon sensor type used.
The ED810 is designed for use in 12V or 24V DC insulated and earthed return electrical systems. For insulated return systems special consideration should be given to the “Hazardous Area common connection” terminal. This should normally be connected to a good quality earth suitable for intrinsically safe equipment. However this terminal is internally connected to 0V
Attention is drawn to the need for correct cabling, particularly to the sensors located in the Hazardous Area. The cable supplied by EDL for use with the ED810 has been tested to ensure correct parameters, see installation section of this manual.
Attention is also drawn to the need for calibration soon after installation. When supplied alarm levels are approximately set for the target gas (if stated with order) so that a measure of immediate protection is obtained once correct operation has been ensured.
ED810 INSTRUCTION MANUAL | 3 |