Bacharach 3015-4286 manual Edit Evac Level 0500 PPM

Page 20

DIAGNOS – Enters the diagnostic function. Press the Up Arrow Keypad button to toggle between the monitor’s two diagnostic screens. Refer to Working with the DIAGNOS Function (Page 21).

4.26500v <0000> 24.5cD 14.00psi

0.4ppm 0.00 0.00002au 4.260v

GASTYPE – Ammonia monitors do not have a library of other gases to choose from, therefore R717 is the only gas type listed. Press QUIT to return to the previous screen.

LEAKLVL – Sets the Leak Alarm level, adjustable from 1 to 300 ppm. Factory default is 100 ppm. Note that the Leak Alarm level cannot be set higher than either the Spill or Evacuate Alarm levels. Use the Keypad to set the desired Leak Alarm level, and then press ENTER to save that level and return to the previous screen.

SPILLLVL – Sets the Spill Alarm level, adjustable from no lower than the Leak Alarm level to a maximum value of 500 ppm, but not higher than the Evacuate Alarm level. Factory default is 300 ppm. Use the Keypad to set the desired Spill Alarm level, and then press ENTER to save that level and return to the previous screen.

EVACLVL – Sets the Evacuate Alarm level, adjustable from no lower than the Spill Alarm level to 9999 ppm. Factory default is 500 ppm. Use the Keypad to set the desired spill level alarm level, and then press ENTER to save that level and return to the previous screen.

LOG INT – Sets the interval at which measurements are logged to memory from 1 to 9999 minutes. Factory default is 10 minutes. Note that the logged measurements can be viewed using the PPM LOG function. Use the Keypad to enter the desired value, and then press ENTER to save that value and return to the previous screen.

LOOP – Adjusts the loop factor of the 4–20 mA current loop. Factory default is 0.016 mA per ppm, which provides an output range of 0 ppm (4 mA) to 1,000 ppm (20 mA). Use the Keypad to set the desired loop factor, and then press ENTER to save that value and return to the previous screen.

To facilitate loop zero and span checking, note that when the LOOP function is selected the loop output is set to 20 mA, and upon exiting this function the loop output is set to 4 mA.

AUDALRM Allows the monitor’s internal audible alarm to be associated with any function of the monitoring system. Factory default is OFF. Use the Keypad to select the desired audible alarm function, and then press ENTER to save that value and return to the previous screen.

Audible Alarm Settings: OFF, ANY ALARM, SYSTEM FAULT, LEAK ALARM, SPILL ALARM, EVAC ALARM, MONITOR STOPPED

NOTE: MONITOR STOPPED indicates there is a critical system fault, and the monitor is no longer functioning correctly.

SELECT GAS TYPE R717

EDIT LEAK LEVEL 0100 PPM

EDIT SPILL LEVEL

0300 PPM

EDIT EVAC LEVEL 0500 PPM

LOG INTERVAL IS 0010 min

EDIT LOOP FACTOR

0.016 ma/PPM

AUDIBLE ALARM IS OFF

16

Instruction 3015-4286

Image 20
Contents Rev September Installation / Operation / MaintenanceAgmsz Ammonia Gas Monitor Single Zone Warranty Register Your Warranty by VisitingTable of Contents Maintenance Introduction How to Use This ManualHazard Symbols on Monitor Safety Precautions Understanding Monitoring Levels Functional OverviewGeneral Description Agmsz Refrigerant Gas Leak Monitor Mechanical Room Placement Suggested Location of Sampling PointInstallation Installation ConsiderationsInspection Locating the MonitorConnecting Gas Sample, Purge, and Exhaust Lines Mounting InstructionsOverview Enclosure Mounting SpecsConnecting the Gas-Sample Line Connecting the Purge LineConnecting the Exhaust Line Tubing ConsiderationsInterior Schematic Interior SchematicElectrical Wiring AC Power ConnectionsConnection Connecting External AlarmsExternal Alarm Relay Connector MA Current Loop Interface Typical External Alarm Relay 1 WiringMA Current Loop Connector Instruction General Operation OperationFront Panel Display and Controls Data Display Screen Initial Power UpDisplay Screens Function Screens Edit Evac Level 0500 PPM R717 Calfactor Working with Gas Alarms Working with System FaultsClearing / Silencing a Gas Alarm Viewing the Gas Alarm LogViewing the Fault Log Fault CodesClearing the Stored PPM Log, Alarm & Fault Data Working with the P-CHK FunctionKeypad Functions Screen DisplayWorking with the Diagnos Function First Diagnostic ScreenSecond Diagnostic Screen Working with the Calibration Function Calibration ProcedureAdjusting Calibration Factor Maintenance Optional Accessories Replacement Parts & Optional AccessoriesReplacement Parts Service Centers Specifications Years from date of shipmentInstruction Headquarters Hunt Valley Circle, New Kensington, PA

3015-4286 specifications

Bacharach 3015-4286 is an innovative and versatile instrument, specifically designed for professionals in industries where air quality monitoring is paramount. This model stands out due to its advanced features and technologies, making it a preferred choice for those needing accurate and reliable measurements of various gases.

One of the main features of the Bacharach 3015-4286 is its multi-gas detection capability. It can simultaneously monitor up to five different gases, providing users with a comprehensive understanding of their environment in real-time. This is particularly beneficial in applications such as HVAC, refrigeration, and industrial processes, where the presence of gases like carbon dioxide, ammonia, and refrigerants can have significant safety and regulatory implications.

The device utilizes state-of-the-art sensors that ensure high sensitivity and selectivity to the target gases. These sensors are designed for quick response times, allowing users to detect any changes in gas concentrations almost instantaneously. This responsiveness is crucial for environments where rapid decision-making is necessary to ensure safety and compliance with environmental regulations.

In addition to its gas detection capabilities, the Bacharach 3015-4286 features a user-friendly interface. The large display screen provides clear readouts, and the intuitive navigation system allows users to easily switch between different measurement modes and settings. This accessibility makes it suitable for both experienced professionals and those who may be new to gas monitoring technologies.

Battery life is another characteristic that sets the Bacharach 3015-4286 apart from its competitors. With efficient power management, the device can operate continuously for extended periods without the need for frequent recharging or battery replacement. This reliability is crucial for fieldwork, where access to power sources may be limited.

Moreover, the device is compact and lightweight, enhancing its portability. Users can easily transport the Bacharach 3015-4286 to various job sites without inconvenience. Its robust design ensures durability in diverse working conditions, further establishing it as a dependable tool in the field.

In summary, the Bacharach 3015-4286 is a cutting-edge gas detection instrument offering multi-gas detection, advanced sensors, user-friendly operation, long battery life, and portability. These features make it an indispensable asset for professionals seeking to ensure safety and compliance in their working environments.