Bacharach 3015-4286 manual Introduction, How to Use This Manual, Hazard Symbols on Monitor

Page 5

Introduction

How to Use This Manual

Thank you for investing in a BACHARACH AGMSZ (Ammonia Gas Monitor Single Zone).

This manual provides important information on how to install, operate, and service the AGMSZ monitoring unit.

To assure operator safety and the proper use of the monitor, please read, understand, and follow the contents of this manual.

If you have a working knowledge of gas monitors, you will find this manual useful as a reference tool. If you are new to the use of gas monitors, you can educate yourself about the principles of gas detection and the proper operation of this device by reading this manual thoroughly.

Warning Statements

The use of the word WARNING in this manual denotes a potential hazard associated with the use of this equipment. It calls attention to a procedure, practice, or condition, or the like, which if not correctly performed or adhered to, could result in personal injury or death.

Caution Statements

The use of the word CAUTION in this manual denotes a potential hazard associated with the use of this equipment. It calls attention to a procedure, practice, condition, or the like, which if not correctly performed or adhered to, could result in damage to the equipment.

Hazard Symbols on Monitor

This symbol indicates the need to consult this operating instruction manual when opening the enclosure.

WARNING: A potential risk exists if the operating instructions are not followed.

This symbol indicates the presence of electric shock hazards when the enclosure is opened.

WARNING: To avoid risk of injury from electric shock, do not open the enclosure without first disconnecting AC power.

Instruction 3015-4286

1

Image 5
Contents Rev September Installation / Operation / MaintenanceAgmsz Ammonia Gas Monitor Single Zone Register Your Warranty by Visiting WarrantyTable of Contents Maintenance Introduction How to Use This ManualHazard Symbols on Monitor Safety Precautions Understanding Monitoring Levels Functional OverviewGeneral Description Suggested Location of Sampling Point Agmsz Refrigerant Gas Leak Monitor Mechanical Room PlacementInstallation Considerations InstallationInspection Locating the MonitorMounting Instructions Connecting Gas Sample, Purge, and Exhaust LinesOverview Enclosure Mounting SpecsConnecting the Purge Line Connecting the Gas-Sample LineConnecting the Exhaust Line Tubing ConsiderationsInterior Schematic Interior SchematicAC Power Connections Electrical WiringConnection Connecting External AlarmsExternal Alarm Relay Connector MA Current Loop Interface Typical External Alarm Relay 1 WiringMA Current Loop Connector Instruction General Operation OperationFront Panel Display and Controls Data Display Screen Initial Power UpDisplay Screens Function Screens Edit Evac Level 0500 PPM R717 Calfactor Working with System Faults Working with Gas AlarmsClearing / Silencing a Gas Alarm Viewing the Gas Alarm LogFault Codes Viewing the Fault LogWorking with the P-CHK Function Clearing the Stored PPM Log, Alarm & Fault DataKeypad Functions Screen DisplayWorking with the Diagnos Function First Diagnostic ScreenSecond Diagnostic Screen Working with the Calibration Function Calibration ProcedureAdjusting Calibration Factor Maintenance Optional Accessories Replacement Parts & Optional AccessoriesReplacement Parts Service Centers Years from date of shipment SpecificationsInstruction Headquarters Hunt Valley Circle, New Kensington, PA

3015-4286 specifications

Bacharach 3015-4286 is an innovative and versatile instrument, specifically designed for professionals in industries where air quality monitoring is paramount. This model stands out due to its advanced features and technologies, making it a preferred choice for those needing accurate and reliable measurements of various gases.

One of the main features of the Bacharach 3015-4286 is its multi-gas detection capability. It can simultaneously monitor up to five different gases, providing users with a comprehensive understanding of their environment in real-time. This is particularly beneficial in applications such as HVAC, refrigeration, and industrial processes, where the presence of gases like carbon dioxide, ammonia, and refrigerants can have significant safety and regulatory implications.

The device utilizes state-of-the-art sensors that ensure high sensitivity and selectivity to the target gases. These sensors are designed for quick response times, allowing users to detect any changes in gas concentrations almost instantaneously. This responsiveness is crucial for environments where rapid decision-making is necessary to ensure safety and compliance with environmental regulations.

In addition to its gas detection capabilities, the Bacharach 3015-4286 features a user-friendly interface. The large display screen provides clear readouts, and the intuitive navigation system allows users to easily switch between different measurement modes and settings. This accessibility makes it suitable for both experienced professionals and those who may be new to gas monitoring technologies.

Battery life is another characteristic that sets the Bacharach 3015-4286 apart from its competitors. With efficient power management, the device can operate continuously for extended periods without the need for frequent recharging or battery replacement. This reliability is crucial for fieldwork, where access to power sources may be limited.

Moreover, the device is compact and lightweight, enhancing its portability. Users can easily transport the Bacharach 3015-4286 to various job sites without inconvenience. Its robust design ensures durability in diverse working conditions, further establishing it as a dependable tool in the field.

In summary, the Bacharach 3015-4286 is a cutting-edge gas detection instrument offering multi-gas detection, advanced sensors, user-friendly operation, long battery life, and portability. These features make it an indispensable asset for professionals seeking to ensure safety and compliance in their working environments.