Bacharach 3015-4286 manual Installation Considerations, Inspection, Locating the Monitor

Page 9

Installation

Installation Considerations

Warnings and Cautions

WARNING: Explosion hazard! Do not mount the AGMSZ in an area that may contain flammable liquids, vapors or aerosols. Operation of any electrical equipment in such an environment constitutes a safety hazard.

WARNING: Shock hazard! Always disconnect AC power before working inside the monitor.

CAUTION: Drilling holes in the AGMSZ enclosure may damage the unit and will void the warranty. Please use knockouts provided for electrical connections.

CAUTION: The AGMSZ contains sensitive electronic components that can be easily damaged. Be careful not to touch or disturb any of these components.

Inspection

The AGMSZ has been thoroughly inspected and tested prior to shipment from the factory. Nevertheless, it is recommended that the monitor be re-checked prior to installation. Inspect the outside of the enclosure to make sure there are no obvious signs of shipping damage. Open the enclosure and inspect the interior of the monitor for loose components that may have become dislodged during shipment. If damage is discovered, please contact the nearest Bacharach Service Center for assistance.

Locating the Monitor

Locate the AGMSZ so that no more than 50 ft (15.2 m) of tubing will be needed to reach the sampling area.

Since the monitor uses ambient air to purge its gas sensor, the monitor should be located in a well ventilated area that does not contain refrigerant gas. If this is not possible, then it is recommended that a separate purge line be run to an area known to contain fresh (zero) air. The length of this purge line should not exceed 100 ft (30.4 m). If the monitor is located in a confined space, then it is also recommended that a separate exhaust line be run to the outside. The length of this exhaust line should not exceed 50 ft (15.2 m).

The AGMSZ should be operated in an environment that is between 32 and 122°F (0 and 50°C); has a relative humidity of between 5 and 90% non-condensing; and is at an altitude of no more than 6,562 ft (2,000 m). The area should also be relatively free of dirt, grease, and oils that could adversely affect the operation of the monitor.

The location should allow the monitor to be easily accessible for visual monitoring and servicing.

Instruction 3015-4286

5

Image 9
Contents Installation / Operation / Maintenance Agmsz Ammonia Gas Monitor Single ZoneRev September Register Your Warranty by Visiting WarrantyTable of Contents Maintenance How to Use This Manual Hazard Symbols on MonitorIntroduction Safety Precautions Functional Overview General DescriptionUnderstanding Monitoring Levels Suggested Location of Sampling Point Agmsz Refrigerant Gas Leak Monitor Mechanical Room PlacementInstallation Considerations InstallationInspection Locating the MonitorMounting Instructions Connecting Gas Sample, Purge, and Exhaust LinesOverview Enclosure Mounting SpecsConnecting the Purge Line Connecting the Gas-Sample LineConnecting the Exhaust Line Tubing ConsiderationsInterior Schematic Interior SchematicAC Power Connections Electrical WiringConnecting External Alarms External Alarm Relay ConnectorConnection Typical External Alarm Relay 1 Wiring MA Current Loop ConnectorMA Current Loop Interface Instruction Operation Front Panel Display and ControlsGeneral Operation Initial Power Up Display ScreensData Display Screen Function Screens Edit Evac Level 0500 PPM R717 Calfactor Working with System Faults Working with Gas AlarmsClearing / Silencing a Gas Alarm Viewing the Gas Alarm LogFault Codes Viewing the Fault LogWorking with the P-CHK Function Clearing the Stored PPM Log, Alarm & Fault DataKeypad Functions Screen DisplayFirst Diagnostic Screen Second Diagnostic ScreenWorking with the Diagnos Function Calibration Procedure Adjusting Calibration FactorWorking with the Calibration Function Maintenance Replacement Parts & Optional Accessories Replacement PartsOptional Accessories Service Centers Years from date of shipment SpecificationsInstruction Headquarters Hunt Valley Circle, New Kensington, PA

3015-4286 specifications

Bacharach 3015-4286 is an innovative and versatile instrument, specifically designed for professionals in industries where air quality monitoring is paramount. This model stands out due to its advanced features and technologies, making it a preferred choice for those needing accurate and reliable measurements of various gases.

One of the main features of the Bacharach 3015-4286 is its multi-gas detection capability. It can simultaneously monitor up to five different gases, providing users with a comprehensive understanding of their environment in real-time. This is particularly beneficial in applications such as HVAC, refrigeration, and industrial processes, where the presence of gases like carbon dioxide, ammonia, and refrigerants can have significant safety and regulatory implications.

The device utilizes state-of-the-art sensors that ensure high sensitivity and selectivity to the target gases. These sensors are designed for quick response times, allowing users to detect any changes in gas concentrations almost instantaneously. This responsiveness is crucial for environments where rapid decision-making is necessary to ensure safety and compliance with environmental regulations.

In addition to its gas detection capabilities, the Bacharach 3015-4286 features a user-friendly interface. The large display screen provides clear readouts, and the intuitive navigation system allows users to easily switch between different measurement modes and settings. This accessibility makes it suitable for both experienced professionals and those who may be new to gas monitoring technologies.

Battery life is another characteristic that sets the Bacharach 3015-4286 apart from its competitors. With efficient power management, the device can operate continuously for extended periods without the need for frequent recharging or battery replacement. This reliability is crucial for fieldwork, where access to power sources may be limited.

Moreover, the device is compact and lightweight, enhancing its portability. Users can easily transport the Bacharach 3015-4286 to various job sites without inconvenience. Its robust design ensures durability in diverse working conditions, further establishing it as a dependable tool in the field.

In summary, the Bacharach 3015-4286 is a cutting-edge gas detection instrument offering multi-gas detection, advanced sensors, user-friendly operation, long battery life, and portability. These features make it an indispensable asset for professionals seeking to ensure safety and compliance in their working environments.