cerebrospinal fluid leak, recent cranial surgery, or trauma.

WARNINGS

The entire manual should be read before using the S8 AUTOSET SPIRIT.

Advice contained in this manual should not supersede instructions given by the prescribing physician.

A patient should not connect a device to the data communication port unless instructed to do so by their health care provider or physician. Only ResMed products are designed to be connected to the data communication port. Connecting other devices could result in injury, or damage to the S8 AUTOSET SPIRIT device.

The S8 AUTOSET SPIRIT should only be used with masks (and connectors)* recommended by ResMed, or by a physician or respiratory therapist. A mask should not be used unless the S8 AUTOSET SPIRIT device is turned on and operating properly. The vent hole or holes associated with the mask should never be blocked.

Explanation: The S8 AUTOSET SPIRIT is intended to be used with special masks (or connectors)* which have vent holes to allow continuous flow of air out of the mask.

When the device is turned on and functioning properly, new air from the device flushes the exhaled air out through the mask vent holes. However, when the device is not operating, insufficient fresh air will be provided through the mask, and the exhaled air may be rebreathed. Rebreathing of exhaled air for longer than several minutes can, in some circumstances, lead to suffocation. This applies to most models of CPAP devices.

In the event of power failure or machine malfunction, remove the mask.

The S8 AUTOSET SPIRIT can be set to deliver pressures up to 20 cmH2O. In the unlikely event of certain fault conditions, pressures up to 30 cmH2O are possible.

If oxygen is used with this device, the oxygen flow must be turned off when the device is not operating.

Explanation: When the CPAP device is not in operation and the oxygen flow is left on, oxygen delivered into the air delivery tubing may accumulate within the CPAP machine enclosure and create a risk of fire. This applies to most types of CPAP machines.

Oxygen supports combustion. Oxygen should not be used while you are smoking or in the presence of an open flame.

Always ensure airflow is being generated by the device before the oxygen supply is turned on.

Always turn the oxygen supply off before stopping the airflow from the device. Note: At a fixed rate of supplemental oxygen flow, the inhaled oxygen concentration

*Ports may be incorporated into the mask or in connectors that are near the mask.

2

Image 8
Contents S8 AutoSet Spirit System Blank Module S8 AutoSet Spirit System Manufactured by Contents Cleaning and Maintenance Introduction Medical InformationPage Adverse Effects Page S8 Autoset Spirit System You will also need a ResMed mask system supplied separatelyHumidifier HOW to USE the S8 Autoset Spirit Fit your mask as described in the mask user instructions Excelnt Definitions of Mask-Fit Star Rating Star rating HOW to Attach a Humidifier Page HOW to USE the Keypad LCD ScreenPress the Right key Exit HOW to Change the Ramp or Settling Time Page HOW to USE the Standard Menu Autoset WelcomeSettings for mask types Mask HOW to USE the Detailed Menu CpapHOW to Change the Tube Length To change the option to on or OFF Message Description Action S8 Modules Insert the Data Card S8 Modules Page Cleaning and Maintenance Replacing the AIR Filter Frequently Asked Questions What do I do When I Want to GET UP in the NIGHT?Altitude Changes Troubleshooting Problem Possible Cause SolutionProblem Possible Cause Solution System Error Settings Success Remove Card System Specifications Dimensions H x W x D 112 mm x 164 mm x 145 mm Weight 1.3 kgElectromagnetic Compatibility System Specifications Page Recommended separation distance Separation distance according to frequency of transmitter Limited Warranty Product Warranty PeriodPage Index PCB
Related manuals
Manual 39 pages 19.68 Kb Manual 158 pages 44.94 Kb Manual 88 pages 45.08 Kb Manual 47 pages 54.64 Kb Manual 20 pages 25.84 Kb

s8 specifications

The ResMed S8 Escape is a highly regarded CPAP (Continuous Positive Airway Pressure) device designed for the treatment of obstructive sleep apnea. Known for its reliability and user-friendly features, the S8 Escape is part of ResMed’s S8 series, which combines advanced technologies with an emphasis on patient comfort.

One of the standout features of the S8 Escape is its AutoRamp technology, which helps patients gradually transition into their prescribed pressure settings. Instead of starting at the full pressure immediately, AutoRamp begins at a lower pressure, allowing users to fall asleep comfortably before automatically increasing to the prescribed level. This feature significantly improves the overall user experience as it reduces anxiety associated with the use of CPAP devices.

The S8 Escape also boasts a built-in air filter that enhances air quality and protects the device from dust and other particulates. Additionally, the device is designed for whisper-quiet operation, ensuring that users can sleep soundly without the disruption of noise, which can be a common issue with less advanced models. This creates a more peaceful sleeping environment, both for the user and their bed partner.

Another important characteristic of the S8 Escape is its compact design and lightweight build. It is easily portable, making it an ideal choice for both home use and travel. The device also features a user-friendly interface, with a simple LCD screen that displays essential information such as pressure settings and therapy time. This allows users to track their usage and monitor their therapy progress conveniently.

The S8 Escape offers various pressure settings and is compatible with a wide range of masks, ensuring that users can find the right fit for their individual needs. The device’s advanced monitoring capabilities also help in providing feedback on therapy effectiveness, allowing healthcare professionals to adjust settings if necessary.

In summary, the ResMed S8 Escape is a highly functional and patient-friendly CPAP device, featuring advanced technologies designed to enhance the user experience. Its AutoRamp technology, quiet operation, and compact design make it a popular choice among individuals dealing with obstructive sleep apnea.