Using the dehumidifier.

GEAppliances.com

When first using the dehumidifier, operate the unit continuously 3 to 4 days.

Safety

How the Dehumidifier Operates

Moist, humid air is drawn over a cold refrigerated dehumidifying coil. Moisture in the air condenses on this coil and drains into a bucket (or through the bucket into a hose and drain).

Dry, clean air is drawn over the condenser where it is actually heated several degrees and discharged out the front grille into the room.

It is normal for the surrounding air to become slightly warmer as the dehumidifier operates.

This warming effect further reduces the relative humidity of the surrounding air.

Evaporator

Condenser

Humidistat

Fan

Humid air in

 

 

 

Drain pan

 

 

Drain connector

Dry air out

Bucket Compressor

Instructions Operating Instructions

Choosing a Location

The dehumidifier must be operated in an enclosed area to be most effective.

Close all doors, windows and other outside openings to the room.

Place the dehumidifier in a location that does not restrict air flow into the rear coil or out the front grille.

A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area.

Care and Cleaning

Removing Collected Water

There are 3 ways to remove collected water:

Use the bucket. When the bucket is removed, the unit will shut off. Empty and replace the bucket.

Use a hose. Water can be automatically emptied into a floor drain by attaching a water hose to the bucket. Using a drill, make a hole at the end of the nozzle located on the lower left side of the bucket. Attach a water hose to the bucket nozzle.

Nozzle

Hose

Use a floor drain. The unit can also be placed over a floor drain. Using a drill, make a hole at the end of the nozzle located on the lower left side of the bucket.

Nozzle

NOTE: The nozzle cannot be fixed after puncture. Use an ordinary garden hose cap to reclose if necessary.

5

Troubleshooting Tips Consumer Support

Image 5
Contents 3828A30059N 49-7431 12-01 JR DehumidifiersConsumer Support TroubleshootingTips Care and Cleaning OperatingInstructions Safety InstructionsGEAppliances.com Tips Consumer SupportHumidity Control About the controls on the dehumidifierFan Speed Care and Cleaning Using the dehumidifierSafety Water Level Consumer Support TroubleshootingTips Care and CleaningInstalling the Water Bucket Cleaning Inside the Unit Care and cleaning of the dehumidifierGrille and Case Air FilterBefore you call for service… We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration Troubleshooting Tips Consumer Support Dehumidifier WarrantyWhat Is Not Covered For The Period We Will ReplaceParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio
Related manuals
Manual 12 pages 58.68 Kb

AHG50 specifications

The GE AHG50 is a cutting-edge gas turbine generator that has been making waves in the energy sector due to its advanced design and efficiency. This turbine is part of the Advanced Gas Path (AGP) technology family, which has been specifically engineered to optimize performance and increase operational flexibility. With a focus on reliability and sustainability, the GE AHG50 stands out for its enhanced efficiency and lower emissions, making it an attractive option for various applications, including power generation and industrial processes.

One of the main features of the GE AHG50 is its modular design, which allows for easier maintenance and quicker upgrades. The turbine is equipped with the latest materials and cooling technologies, enabling it to operate at higher temperatures without sacrificing durability. This capability translates into improved efficiency, as it allows the turbine to extract more energy from the fuel being burned.

In terms of characteristics, the GE AHG50 boasts a power output of approximately 50 megawatts, making it suitable for both distributed energy systems and larger utility-scale projects. The turbine's high efficiency rating not only reduces fuel consumption but also translates into lower operational costs for users. Moreover, the AHG50 can easily integrate with various renewable energy sources, such as solar and wind, to create hybrid systems that enhance overall grid stability and reliability.

The turbine also features advanced digital controls, leveraging GE’s expertise in analytics and software technologies to optimize performance and predictive maintenance. This digital capability is essential for monitoring the turbine's health, allowing operators to identify potential issues before they lead to costly downtime.

With its robust design and advanced technologies, the GE AHG50 is primed to meet the demands of a rapidly evolving energy landscape. It provides a reliable, efficient, and environmentally friendly solution for energy generation, making it an ideal choice for power plants aiming to enhance productivity while adhering to stricter emissions regulations.

Overall, the GE AHG50 gas turbine generator represents a significant advancement in turbine technology, combining efficiency, flexibility, and sustainability into a single package. With its impressive features and state-of-the-art engineering, it is well-positioned to play a vital role in the future of power generation.