Lennox International Inc 021, 505 Insulating and Sealing the Unit, Other System Components

Page 9

Insulating and Sealing the Unit

IMPORTANT

All piping, metering devices, and connections must be insulated to prevent moisture damage caused by sweating.

Seal the unit so that warm air is not allowed into the cabi- net. This is especially important when the unit is installed in an unconditioned area. Make sure the liquid line entry points are sealed with either refrigerant tube insulating ma- terial or with Permagum (see figure 5 on page 7).

Other System Components

Blower Control

EDA units are to be applied with an indoor unit that has a variable speed motor (VSM). Refer to the indoor unit instal- lation instruction for setting blower speed.

Thermostat and Sensor

IMPORTANT

A SignatureStatt thermostat and properly- connected outdoor sensor is REQUIRED for the EDA unit to function properly. Twisted pair wire (84X49 or equivalent) is REQUIRED between the SignatureStat and the outdoor sensor.

Install the remote sensor on the outside of a northern wall of the home, away from direct sunlight or other heat sources that may affect its sensitivity.

Refer to the SignatureStatt thermostat Installation Instructions for installation, wiring, and setup. Also refer to the SignatureStatt Thermostat Programming Guide for programming and settings.

To configure the thermostat for operation with a Humidi- trol® system, first enable HUMIDITROL in the thermostat’s installer settings (follow the path: MENU −> INSTALLER SETTINGS −> HUMIDITROL − see figure 8, A and B).

Then, select HUMIDITROL mode from the DEHUMIDIFY menu (follow the path: MENU −> DEHUMIDIFY). The user control sequence is also shown in figure 8, C through H; specifically:

STurn on Humiditrol − D & E

SSet level of dehumidification − F through H (adjustment range is from 45% to 60% and is factory set to 50%)

If HUMIDITROL is enabled and the outdoor sensor is dis- connected, operation is NOT allowed in dehumidification mode. This is indicated by the display of "OUTSIDE ERR" on the SignatureStatt thermostat Home screen.

Setting Thermostat

Installer Setup

 

INSTALLER SETTINGS Y

 

 

HUMIDITROL

 

AUTO CHANGEOVER

ON

 

 

 

 

 

EER

ON

 

 

DISABLE

 

DEADBAND

4.0°F

 

 

ENABLE

 

 

HUMIDITROL

 

OFF

 

 

 

 

 

MAIN MENU SELECT

B

 

INSTALL MENU SELECT

 

 

 

 

 

 

 

 

 

 

 

 

A

 

User Controls

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAIN MENU

 

 

 

DEHUMIDIFY MENU

 

PROGRAM

 

 

 

 

 

MODE

 

 

OFF

 

HEAT / COOL

 

 

 

 

DEHUMIDIFY

50%

 

HUMIDIFY

 

 

 

 

 

 

 

 

 

DEHUMIDIFY

 

 

 

 

 

 

 

 

 

 

 

HOME

SELECT

 

 

MAIN MENU

SELECT

 

 

 

 

C

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

DEHUMIDIFY MODE

 

 

DEHUMIDIFY MENU

 

OFF

 

 

 

 

 

MODE

HUMIDITROL

 

HUMIDITROL

 

 

 

 

 

 

DEHUMIDIFY

 

50%

 

DEHUM MENU

SELECT

 

 

MAIN MENU

SELECT

 

 

 

 

E

 

 

 

 

 

 

 

F

 

DEHUMIDIFY

 

 

 

DEHUMIDIFY MENU

 

 

CONTROL

 

 

 

MODE

HUMIDITROL

 

 

 

 

 

 

 

 

 

DEHUMIDIFY

 

55%

 

 

50

%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEHUM MENU

SELECT

 

 

MAIN MENU

SELECT

 

 

 

 

G

 

 

 

 

 

 

 

H

Figure 8

Page 9

EDA INSTALLATION/ SERVICE INSTRUCTIONS

Image 9
Contents Table of Contents Humiditrol Enhanced Dehumidification Accessory EDA UnitsHumiditrol EDA Series Unit Shipping & Packing ListEDA Model Dimensions − Inches mm Unit DimensionsInstallation Dimensions and Arrangement Furnace ShownPosition Furnace Shown Component Functions Check/Flow Restrictor OperationEDA Unit Parts Arrangement EDA−024B EDA−036C EDA−060D General Installation Information Electrical WiringEDA Installation and Checkout Flow Chart Required Parts all applications EDA Installation & Checkout Flow ChartDetails Typical Installation Horizontal Air Handler shownLeak Testing, Evacuating, Charging Insulating and Sealing the Unit Setting ThermostatOther System Components Blower ControlEDA Unit Operation Operation NotesCooling Cycle with EDA Coil Active Model EDA−036C shown Cooling Cycle with EDA Coil Inactive Model EDA−036C shown Check List Demand Signals − Humiditrol EDA EnabledWiring Diagrams Repair PartsControl Wiring Requirements Air ResistanceControl Wiring Typical EDA/Condensing Unit Wiring DiagramTypical EDA/Heat Pump Wiring Diagram Start