The supply line shall be equipped with an approved shutoff valve. This valve should be located in the same area as the burner and should be in a location that allows ease of opening and closing. Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the appliance.
B
A
C
A. Gas supply line
B. Open position of shutoff valve
C. To side burner
LP gas conversion from a local LP gas supply:
Conversion must be made by a qualified person. A qualified natural gas technician shall provide the LP gas supply to the selected side burner location in accordance with the National Fuel Gas Code ANSI Z2223.1/NFPA54 latest edition, and local codes.
To convert to LP gas, the LP Gas Conversion Kit Number W10118099 must be used. Follow Instructions included with kit.
LP gas conversion using a 20 lb LP fuel tank:
To convert to LP gas, the LP Gas Conversion Kit Number W10118099 must be used. Follow Instructions included with kit.
A 20 lb (9.1 kg) LP gas fuel tank must be purchased separately.
INSTALLATION INSTRUCTIONS
Outdoor Side Burner Installation
WARNING
Excessive Weight Hazard
Use two or more people to move and install side burner.
Failure to do so can result in back or other injury.
■Unpack side burner. Remove all packaging materials and remove side burner from carton.
■Move side burner close to desired outdoor location.
Make Gas Connection
Natural Gas Use
This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with either the National Fuel Gas Code ANSI Z223.1 - latest edition, or
1.Place side burner into outdoor enclosure, but leave enough room in back to connect to gas supply and plug in electrical
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor” gas supply line.
Securely tighten all gas connections.
Failure to do so can result in death, explosion, or fire.
2.A combination of pipe fittings must be used to connect the side burner to the existing gas line. If local codes permit, use an outdoor flexible stainless steel tubing gas connector,
Natural gas must be used. Do not use TEFLON®† tape.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
3.Using a wrench to tighten, connect the gas supply to the side burner. Use
A
B
DC
A. ½" side burner gas pipe
B. New CSA International approved “outdoor” flexible gas supply line
C. Rear of side burner D. To Natural gas supply
4.Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.
A
B
A. Closed valve
B. Open valve
5.Test all connections by brushing on an approved noncorrosive