Converting Side Burner from LP to NG
When converting an LP side burner that is connected to an LP grill, you MUST convert both appliances..
It is dangerous to have an LP appliance and an NG appliance supplied by the same fuel..
WARNING! You must have an authorized service technician perform this procedure.. If these instructions are not followed exactly, a fire or explosion may result causing property dam- age, personal injury or loss of life.. Lloyd’s Material Supply (LMS) will not be held responsible for an improperly converted gas side burner..
All Cal Heat side burners are manufactured to use standard liquid pro- pane (LP) and can be converted to burn natural gas (NG).
You will need one or two orifices (depending on the size of the side burner), contained in the conversion kit provided with the side burner. The conversion kit contains orifices to convert five main burners, two small rear infrared burners, one large infrared burner, and two side burners. You will not need all of the parts in the kit.
Before you begin, make certain the LP gas source has been discon- nected.
Replacing the side burner orifices
1.Remove the grate, burner cap and burner diffuser from the side burner.
2.Using a 7mm wrench, remove the orifice for the burner.
3.Apply a small amount of pipe compound to the orifice threads.
4.Screw in the orifice until it is finger tight.
5.Tighten the orifice with the 7mm wrench.
6.If you have dual side burners, repeat the previous steps for the second burner.
Cal Flame Side Burners
21 Appendix
LTR50001082, Rev. B | www.calspas.com |