Beckett CG50, CG25 manual Maximum Capacity at 3% O2 vs Furnace Pressure CG15, 60Hz

Page 8

Section: Pre-installation Checklist

Figure 3A - Maximum Capacity (at 3% O2) vs Furnace Pressure - CG15, 60Hz.

Figure 3B - Maximum Capacity (at 3% O2) vs Furnace Pressure - CG25, 60Hz.

Figure 3C - Maximum Capacity (at 3% O2) vs Furnace Pressure - CG50, 60Hz.

8

Image 8
Contents Fire, Explosion and Asphyxiation Hazards Page Contents General Information Hazard DefinitionsOwner’s Responsibility Frozen Plumbing Water Damage HazardPre-installation Checklist Burner Specifications Burner Label LocationVerify Burner Air Tube Assembly Test For Gas Pipe LeaksElectrical Supply Verify Burner ComponentsMaximum Capacity at 3% O2 vs Furnace Pressure CG15, 60Hz Burner Dimensions Mount the Burner Connect Gas PipingProtect the Air Tube from Overheating Do Not Use Teflon Tape on Gas PipingInstall a Drip Leg in Gas Supply Piping Gas Trains Gas Leaks and Explosion HazardsNatural Gas Supply Piping Capacity Propane LP Gas Supply Piping CapacityUL Gas Train High/Low and Low Fire Start Pipe SizeWire the Burner Do Not Bypass Safety ControlsKeep Service Access Covers Securely Installed Sequence of OperationSection Sequence of Operation Section Sequence of Operation Prepare the Burner for Start-up Professional Installation Service RequiredDelayed Ignition, Explosion Fire Hazards Burner Start Procedure Initial Air SettingsStart the Burner Test InstrumentsDamper Motor with Cover Optional Modulation Linkage Adjustment Instructions Adjustment ProcedureInitial Burner Settings for Both Propane & Natural Gas CG50Modulation Control Display MeaningVerify Input Firing Rate Temperature Correction Estimating RateClocking a Gas Meter Uncorrected Flow RateCG15.4S CG15.3S800 CG15.2S CG15.1S 600 400 200 500Technician Required Check Operation and Safety ControlsTesting by Qualified Recommended Combustion Test Sequence Use Test Instruments to Set CombustionMaintenance and Service Annual Professional Service RequiredAnnual Maintenance Turn Off Electric and Gas Supply Before ServicingFlame Safeguard Installation AreaAdjust the Burner for Proper Combustion Gas Supply PipingGas Gun Assembly Installation Propane Restrictor DescriptionNumbers As shown in Figures 16Test/Inspection Frequency Comments For the Operator Inspect Heating System RegularlyPeriodic Inspection Sheet Replacement Parts Item Description CG15 Part No CG25 Part No CG50 Part No See TableLimited Warranty Information
Related manuals
Manual 2 pages 33.71 Kb

CG25, CG50, CG15 specifications

Beckett CG25, CG15, and CG50 are advanced burner systems designed for optimal performance in residential and commercial heating applications. Developed with state-of-the-art technology, each model offers distinct features and characteristics tailored to meet varying demands.

The Beckett CG25 is engineered for medium-output applications, providing reliable heating with exceptional efficiency. One of its standout features is the high-performance combustion head which enhances the air-fuel mixing process, leading to improved burn quality and reduced emissions. Additionally, the CG25 incorporates a fully automatic control system that allows for precise temperature regulation, contributing to energy savings and lower operational costs.

The Beckett CG15, meanwhile, is ideal for smaller residential systems. It stands out for its compact design, making it easy to install in tight spaces. Despite its size, the CG15 does not compromise on performance. It features advanced flame retention technology, which ensures a stable and efficient burn, while its low noise operation adds convenience for users. The CG15 also benefits from a robust safety system that includes a lockout feature to prevent unsafe operation.

On the higher end, the Beckett CG50 is designed for larger heating applications and is capable of generating high outputs while maintaining fuel efficiency. Its innovative design encompasses a three-stage combustion process that enhances efficiency and minimizes emissions significantly. The CG50 also features advanced diagnostic capabilities, providing real-time feedback and enabling proactive maintenance, which increases reliability and prolongs equipment life.

All three models are built with durability in mind, utilizing high-quality materials to withstand harsh operating conditions. They are compatible with various types of fuel, including oil and gas, making them versatile solutions for a broad range of heating needs. Beckett's commitment to sustainability is evident in the design of these burners, as they comply with stringent environmental regulations.

In conclusion, the Beckett CG25, CG15, and CG50 systems represent a blend of innovative technology, efficiency, and robust design. Their unique features cater to different heating demands, making them suitable for various applications while ensuring both performance and reliability. Whether for residential or commercial use, these burners are ideal choices for anyone looking to invest in a high-quality heating solution.