INSTALLATION,

OPERATING AND SERVICE

INSTRUCTIONS FOR

V7 SERIES OIL FIRED BOILER KNOCKDOWN & PACKAGED HEATING UNITS

As an

ENERGY STAR® Partner, Burnham Corporation has determined that the V73WR (0.60 GPH), V74WR (0.80 GPH), V75WR (0.90 GPH), and V76WR (1.15 GPH) meet the ENERGY STAR® guidelines for Energy efficiency established by the United States Environmental Protection Agency (EPA).

These instructions have been reviewed by ULC and found suitable for use in the installation of ULC labeled V-7 Series Boilers.

The ULC label or listed marking on a product is the only evidence provided by Underwriters' Laboratories of Canada to identify products which have been produced under the listing and follow-up service.

For service or repairs to boiler, call your heating contractor. When seeking information on boiler, provide Boiler Model Number and Serial Number as shown on Rating Label.

Boiler Model Number

Boiler Serial Number

Installation Date

_V7 ____-____

6_ _ _ _ _ _ _

 

Heating Contractor

 

Phone Number

Address

8142711R24-7/99

Image 1
Contents Price $3.00 USA Boilers Important Information Please Read this page CarefullySection I General Information Table of ContentsV73 thru V79 Water Boiler with Tankless Heater WBT V713 and V714 Packaged Water Boiler Less Tankless Heater WB Chimney Boiler Above Front Connector Rear Removal of Bare Boiler from Skid Section II Knockdown Boiler AssemblyBoiler Tapping Locations and Usage Knockdown Boilers Only Jacket Front Panel Knockdown Boiler Jacket AssemblyPage Page TS-39-26-A Removal of Boiler from SkidInspect Combustion Target Wall and Combustion Chamber Liner Connect Supply and Return Piping to Heating SystemPage TS-0-63-B TS-O-62-BTankless Heater Data Front Mounted Heater on Water Boilers Tankless Heater Data RearFuel Units and OIL Lines Recommended Smokepipe Arrangement Chimney RequirementsLift H + R See Figure Tubing 3 GPH Manimum Length of TubingMaximum Length of Tubing Boiler Sequence of Operation with Probe Lwco Boiler Sequence of Operation with Float Lwco Sequence of Operation Section IV Operating and Service Instructions Non-Burnham Drawing Copy from other Manual Flame Failure CAD Cell Location and ServiceCheckout Procedure Check for Clean CUT OFF of BurnerTest Controls Primary Relay TestFloat Type LOW Water CUT-OFF Water Boilers Hints on Combustion High Altitude InstallationsFrequent Water Addition IM PO RtantAdjustable Differential Section V Boiler CleaningHigh Limit Operation LOW Limit OperationReassemble Boiler Clean the FireboxUrnham Corporation Regional Offices Section VI Repair PartsBare Boiler Assembly Bare Boiler Assembly See Page 32 for Illustration Bare Boiler Assembly From TS-39-112-D V713 and V714 Flush Jacket Page TS-39-109-D V72 Thru V79 Flush Jacket Jacket Front Panel Assy w/o Htr. Opg. Wtr. Blr V73 Thru V79 Steam Boilers Trim and Controls Description V73 V74 V75 V76 V77 V78 V79 V72 Thru V79, V713 and V714 Water Boilers Trim and Controls Description Beckett AFG Burner Beckett OIL Burner Part NOS. for V7 Series Boilers Print word document

V7 SERIES specifications

The Burnham V7 Series is a standout choice in the realm of residential and light commercial boilers, known for its high efficiency and dependable performance. Engineered for those seeking a reliable heating solution, the V7 Series integrates advanced technologies that prioritize both effectiveness and energy conservation.

At the heart of the Burnham V7 Series is its innovative design that utilizes a cast iron heat exchanger. This robust component ensures excellent durability and longevity while providing efficient heat transfer. The V7's heat exchanger is designed to maximize heating output while minimizing fuel consumption, making it an environmentally friendly option that can help reduce utility costs.

One of the key features of the V7 Series is its ability to operate on multiple fuel sources, including natural gas and propane. This versatility allows homeowners and businesses to choose the most suitable and cost-effective fuel option for their specific needs. The V7 also supports a variety of installation configurations, which makes it adaptable to different spaces and configurations.

The series is equipped with advanced control technologies, including a state-of-the-art electronic ignition system. This system enhances reliability by ensuring a quick and safe start-up while reducing energy waste. Additionally, the integrated boiler control allows users to monitor and adjust their heating settings easily, providing enhanced comfort and efficiency at the touch of a button.

Safety is a top priority in the Burnham V7 Series, which features built-in safety controls to minimize risks. These include thermal overload protection, a pressure relief valve, and a low water cutoff feature, all of which work together to safeguard the boiler and its surroundings.

Moreover, the Burnham V7 Series is designed with a user-friendly interface that makes maintenance straightforward. Routine tasks can be conducted with ease, helping to extend the life of the unit.

In conclusion, the Burnham V7 Series is crafted for those who prioritize efficiency, adaptability, and safety in their heating solutions. With its myriad features and commitment to energy conservation, it stands as a leading choice for heating needs in various settings. The combination of innovative technology, reliable performance, and user-friendly design makes the V7 Series an excellent investment in comfort and efficiency.