Ariston 47-116-17 installation instructions Model 24 Rffi System

Page 44

Model 24 RFFI System

MAKE SURE THAT:

1. There is sufficient water in the system

2. The gas is turned on

3. The electrical supply is turned on

PUSH THE ON/OFF

BUTTON TO ON

TABLE

I and II

SUMMER

IS THE

POWER L.E.D. AND

DISPLAY ON?

YES

DOES A STOP CODE

 

APPEAR ON THE DISPLAY?

POSITION OF THE SUMMER/

WINTER SELECTOR

NO

1. Check the fuses

2.Check the power supply to the control panel

3.Check/replace the ON/OFF button

4.Check the connection between the main and display P.C.B.s

5.Check/replace the

main and display P.C.B.s

WINTER

OFF (green L.E.D. off):

C.H. ONLYcylinder active

SELECTOR

ON/OFF

OFF (green L.E.D. off):

cylinder activeC.H. ONLY

SELECTOR

ON/OFF

ON (green L.E.D. on):

cylinder excluded

The

C.H. flow

temperature

is lower than 80° C YES and the temperature of the

cylinder is at least 5° C below the one selected.

NO

The

C.H. flow

temperature

YES is lower than 80° C and the temperature of the

cylinder is at least 5° C below the one selected.

NO

ON (green L.E.D. on):

cylinder excluded

BUILT-IN

 

 

ELECTRONIC

 

 

ANTI-FROST DEVICE:

 

 

Is there a condition for it to be active?

 

 

(- flow temp. < 3° C

YES

- outdoor temp. < -3°C (outdoor sensor optional)

 

 

- Jumper 4 selects the pump

 

 

for continuous

 

 

operation)

 

 

NO

 

 

 

 

 

THERE IS NO CALL FOR PUMP OPERATION

 

 

 

 

 

 

 

 

MUST

 

YES

 

THE TIME CLOCK

 

 

AND/OR ROOM THERMOSTAT

 

 

 

 

 

BE ACTIVATED?

 

 

 

NO

 

 

 

BUILT-IN

 

 

 

ELECTRONIC

 

 

 

ANTI-FROST DEVICE:

 

 

 

Is there a condition for it to be active?

 

 

YES

(- flow temp. < 3° C

 

 

- outdoor temp. < -3°C (outdoor sensor optional)

 

 

 

-Jumper 4 selects the pump for continuous

operation)

NO

THERE IS NO CALL FOR PUMP OPERATION

A

20

Image 44
Contents Condensing Table of Contents General InformationReference Standards InstallationOverall View Siting the Appliance Overall DimensionsRffi System Mffi Mffi System Minimum ClearancesGAS Connection Mounting the ApplianceMffi System Water ConnectionsFlue Connections Terminal PositionAccessory Connection Room Thermostat ConnectionConnections to the P.CB Under Floor Heating ConnectionElectrical Diagram JumperWater Circuit Diagrams C4 = TimerCommissioning Initial PreparationRemoving the Casing Control Panel Initial START-UPControl Modes Display Messages Shown During Normal OperationOperating Parameters Outdoor Sensor 275 Settings Display Setting the Temperature FieldRegulations Potentiometers Comfort KEYRegulation Menu Table Boiler Safety SystemsPump Overrun Combustion Analysis DrainingGAS Adjustments Changing the Type of GAS Operating TestsZone Valves Maintenance Cleaning the Primary ExchangerCleaning the Condensate Trap General RemarksOperational Test Technical Information Mffi Rffi SystemServicing Instructions Type C Boilers Fault Finding Replacement of Parts To Gain General Access Servicing InstructionsAccess to Removing the side panelsRemoving the sealed chamber front cover Combustion ChamberRemoving the fan Removing the combustion chamber inspection panel Removing the burnerRemoving the electrodes Removing the condensate collector Removing the condensate trap Removing the injectorPage Access to the GAS Valve Removing the gas valveRemoving the D.H.W. secondary exchanger Removing the safety valveAccess to the Water Circuit Removing the main circuit flow switch Removing the D.H.W. flow switchRemoving the automatic air vent Removing the diverter valve actuatorRemoving the pump Removing the pressure gauge Removing the expansion vesselRemoving the C.H. flow temperature probe N.T.C Removing the D.H.W. temperature probe N.T.C. Mffi onlyRemoving the C.H. return temperature probe N.T.C Removing the time clock Access to the Control SystemChecking the fuses Removing the P.C.B.s Page FLOW-CHARTS Fault FindingFault Finding Guide Model 24 Rffi System Model 24 MFFI/24RFFI System Is the FAN Heating flow temperature probe in open circuit Electrical Diagrams JumperC5 = Remote Control Bus+/Bus C1 = FANEcoGENUS 24 Mffi ecoGENUS 24 Rffi Short Spare Parts List Ariston EcoGENUS 24 Rffi System EcoGENUS 24 Rffi System Technical Service Hot Line 01494 Ecogenus 24 Mffi Serial 24MFFIPart Code Description

47-116-17 specifications

The Ariston 47-116-17 is a blend of advanced technology and user-centric design, setting a new standard in home appliances. This washing machine stands out not only for its robust performance but also for its energy-efficient features, making it a top choice for environmentally conscious consumers.

One of the key features of the Ariston 47-116-17 is its impressive capacity. With a drum that can hold up to 7 kg of laundry, it accommodates a variety of household needs, from small loads to larger family washes. This ensures that users can complete their laundry tasks efficiently without multiple wash cycles.

The machine is equipped with a powerful motor that delivers effective cleaning while minimizing noise levels. This is especially beneficial for households where laundry is often done at night or during quiet hours. The appliance operates discreetly, allowing users to run cycles without disturbing the peace of the home environment.

Technology is at the forefront of the Ariston 47-116-17, featuring a comprehensive range of washing programs tailored to suit different fabric types and soil levels. The machine includes specialized settings for delicate fabrics, wool, and heavily soiled garments, ensuring that every item is treated with care. This versatility allows users to maintain the quality of their clothes while achieving optimal cleaning results.

Energy efficiency is another significant characteristic of the Ariston 47-116-17. It boasts a high energy rating, which translates to lower electricity bills and a reduced carbon footprint. The appliance also incorporates water-saving technology, which not only conserves water but also enhances overall efficiency during the wash cycle.

Additionally, the machine is designed with user convenience in mind. Its intuitive control panel makes it easy for users to select the desired programs and settings, even for those who may not be tech-savvy. The digital display provides clear information on remaining wash time, cycle status, and any error messages that may arise.

In conclusion, the Ariston 47-116-17 is a reliable, efficient, and user-friendly washing machine that meets the diverse needs of modern homes. Its combination of capacity, advanced cleaning technologies, energy efficiency, and convenience features makes it a noteworthy addition to any laundry room. Users can enjoy the benefits of powerful performance with the peace of mind that comes from choosing an environmentally responsible appliance.