Ariston 47-116-17 Mffi Mffi System, Minimum Clearances, GAS Connection, Mounting the Appliance

Page 5

2.4.MINIMUM CLEARANCES

In order to allow for access to the interior of the boiler for maintenance purposes, the boiler must be installed in compliance with the clearance requirements indicated in the diagram below.

24 MFFI

FIG. 2.2

24 MFFI SYSTEM

FIG. 2.3

IMPORTANT!

In the event that the power supply cable must be changed, replace it with one with the same specifications. Make the connections to the terminal board located within the control panel, as follows:

-The yellow-green wire should be connected to the terminal marked with the earth symbol; make sure to re-use the ferrule mounted on the other supply cord;

-The blue wire should be connected to the terminal marked “N”;

-The brown wire should be connected to the terminal marked “L”. Note: The diagrams for the electrical system are indicated in section 2.11.

Warning, this appliance must be earthed.

External wiring to the appliance must be carried out by a qualified technician and be in accordance with the current I.E.E. Regulations and applicable local regulations. The Genus range of boilers are

supplied for connection to a 230 V~ 50 Hz supply.

The supply must be fused at 3 A.

The method of connection to the electricity supply must facilitate complete electrical isolation of the appliance, by the use of a fused double pole isolator having a contact separation of at least 3 mm in all poles or alternatively, by means of a 3 A fused three pin plug and unswitched shuttered socket outlet both complying with BS 1363.

The point of connection to the Electricity supply must be readily accessible and adjacent to the appliance unless the appliance is installed in a bathroom when this must be sited outside the bathroom.

2.7.GAS CONNECTION

The local gas region contractor connects the gas meter to the service pipe.

If the gas supply for the boiler serves other appliances ensure that an adequate supply is available both to the boiler and the other appliances when they are in use at the same time.

Pipe work must be of an adequate size. Pipes of a smaller size than the boiler inlet connection should not be used.

2.5.MOUNTING THE APPLIANCE

Fasten the boiler in place using the template and anchors supplied with the unit. It is highly recommended that a spirit level be used to position the boiler so that it is perfectly level.

For additional information, please consult the instructions contained in the connection kit and the flue kit.

2.6.ELECTRICAL CONNECTION

For safety purposes, have a competent person carefully check the electrical system in the property, as the manufacturer will not be held liable for damage caused by the failure to earth the appliance properly or by anomalies in the supply of power. Make sure that the residential electrical system is adequate for the maximum power absorbed by the unit, which is indicated on the rating plate. In addition, check that the section of cabling is appropriate for the power absorbed by the boiler.

The boiler operates with alternating current, as indicated in the technical data table (1.2), where the maximum absorbed power is also indicated. Make sure that the connections for the neutral and live wires correspond to the indications in the diagram. The appliance electrical connections are situated on the reverse of the control panel (see the servicing manual for further information)

275

5

Image 5
Contents Condensing General Information Table of ContentsReference Standards InstallationOverall View Siting the Appliance Overall DimensionsRffi System Minimum Clearances Mffi Mffi SystemGAS Connection Mounting the ApplianceWater Connections Mffi SystemTerminal Position Flue ConnectionsRoom Thermostat Connection Accessory ConnectionUnder Floor Heating Connection Connections to the P.CBJumper Electrical DiagramC4 = Timer Water Circuit DiagramsInitial Preparation CommissioningInitial START-UP Removing the Casing Control PanelControl Modes Display Messages Shown During Normal OperationOperating Parameters Outdoor Sensor 275 Setting the Temperature Field Settings DisplayRegulations Potentiometers Comfort KEYRegulation Menu Table Boiler Safety SystemsPump Overrun Draining Combustion AnalysisGAS Adjustments Operating Tests Changing the Type of GASCleaning the Primary Exchanger Zone Valves MaintenanceCleaning the Condensate Trap General RemarksOperational Test Mffi Rffi System Technical InformationServicing Instructions Type C Boilers Fault Finding Servicing Instructions Replacement of Parts To Gain General AccessRemoving the side panels Access toRemoving the sealed chamber front cover Combustion ChamberRemoving the fan Removing the combustion chamber inspection panel Removing the burnerRemoving the electrodes Removing the condensate collector Removing the injector Removing the condensate trapPage Removing the gas valve Access to the GAS ValveRemoving the D.H.W. secondary exchanger Removing the safety valveAccess to the Water Circuit Removing the D.H.W. flow switch Removing the main circuit flow switchRemoving the automatic air vent Removing the diverter valve actuatorRemoving the pump Removing the expansion vessel Removing the pressure gaugeRemoving the C.H. flow temperature probe N.T.C Removing the D.H.W. temperature probe N.T.C. Mffi onlyRemoving the C.H. return temperature probe N.T.C Removing the time clock Access to the Control SystemChecking the fuses Removing the P.C.B.s Page FLOW-CHARTS Fault FindingFault Finding Guide Model 24 Rffi System Model 24 MFFI/24RFFI System Is the FAN Heating flow temperature probe in open circuit Jumper Electrical DiagramsC1 = FAN C5 = Remote Control Bus+/BusEcoGENUS 24 Mffi ecoGENUS 24 Rffi Short Spare Parts List Ariston EcoGENUS 24 Rffi System EcoGENUS 24 Rffi System Technical Service Hot Line 01494 Ecogenus 24 Mffi 24MFFI SerialPart Code Description

47-116-17 specifications

The Ariston 47-116-17 is a blend of advanced technology and user-centric design, setting a new standard in home appliances. This washing machine stands out not only for its robust performance but also for its energy-efficient features, making it a top choice for environmentally conscious consumers.

One of the key features of the Ariston 47-116-17 is its impressive capacity. With a drum that can hold up to 7 kg of laundry, it accommodates a variety of household needs, from small loads to larger family washes. This ensures that users can complete their laundry tasks efficiently without multiple wash cycles.

The machine is equipped with a powerful motor that delivers effective cleaning while minimizing noise levels. This is especially beneficial for households where laundry is often done at night or during quiet hours. The appliance operates discreetly, allowing users to run cycles without disturbing the peace of the home environment.

Technology is at the forefront of the Ariston 47-116-17, featuring a comprehensive range of washing programs tailored to suit different fabric types and soil levels. The machine includes specialized settings for delicate fabrics, wool, and heavily soiled garments, ensuring that every item is treated with care. This versatility allows users to maintain the quality of their clothes while achieving optimal cleaning results.

Energy efficiency is another significant characteristic of the Ariston 47-116-17. It boasts a high energy rating, which translates to lower electricity bills and a reduced carbon footprint. The appliance also incorporates water-saving technology, which not only conserves water but also enhances overall efficiency during the wash cycle.

Additionally, the machine is designed with user convenience in mind. Its intuitive control panel makes it easy for users to select the desired programs and settings, even for those who may not be tech-savvy. The digital display provides clear information on remaining wash time, cycle status, and any error messages that may arise.

In conclusion, the Ariston 47-116-17 is a reliable, efficient, and user-friendly washing machine that meets the diverse needs of modern homes. Its combination of capacity, advanced cleaning technologies, energy efficiency, and convenience features makes it a noteworthy addition to any laundry room. Users can enjoy the benefits of powerful performance with the peace of mind that comes from choosing an environmentally responsible appliance.