Ariston 47-116-17 installation instructions Table of Contents, General Information

Page 2

TABLE OF CONTENTS

1.GENERAL INFORMATION

1.1.GENERAL INFORMATION

1.3.OVERALL VIEW

2.INSTALLATION

2.1.REFERENCE STANDARDS

2.2.SITING THE APPLIANCE

2.3.OVERALL DIMENSIONS

2.4.MINIMUM CLEARANCES

2.5.MOUNTING THE APPLIANCE

2.6.ELECTRICAL CONNECTION

2.7.GAS CONNECTION

2.8.WATER CONNECTIONS

2.9.FLUE CONNECTIONS

2.10.ACCESSORY CONNECTION

2.10.1.ROOM THERMOSTAT CONNECTION

2.10.2.REMOTE CONTROL CONNECTION

2.10.3.ACCESSORY CONNECTION TERMINAL BLOCK

2.10.4.CYLINDER TEMPERATURE PROBE CONNECTION

2.10.5.REMOTE CONTROL TERMINAL BLOCK AND CYLINDER PROBE

2.11.ELECTRICAL DIAGRAM

2.12.WATER CIRCUIT DIAGRAMS

3.COMMISSIONING

3.1.INITIAL PROCEDURES

3.2.REMOVING THE CASING

3.3.CONTROL PANEL

3.4.INITIAL START-UP

3.5.DISPLAY: MESSAGES SHOWN DURING NORMAL OPERATION

3.6.OPERATING PARAMETERS

3.6.1.CONTROL MODES

3.6.2.OUTDOOR SENSOR

3.6.3.SETTINGS DISPLAY

3.7.REGULATIONS

3.7.1.POTENTIOMETER

3.7.2.SETTING THE TEMPERATURE FIELD

3.7.3.COMFORT KEY/HEATING ONLY

3.7.4.POST-CIRCULATION OF THE PUMP

3.7.5.TEST MODE

3.7.6.REGULATION MENU TABLE

3.8.BOILER SAFETY SYSTEMS

3.9.COMBUSTION ANALYSIS

3.10.DRAINING

4.GAS ADJUSTMENTS

4.1.OVERALL VIEW

4.2.PRELIMINARIES

4.3.GAS REGULATION

4.3.1.TEST OF THE CONNECTION PRESSURE

4.3.2.REGULATION OF THE THERMAL POWER

4.4.CHANGING THE TYPE OF GAS

4.5.OPERATING TESTS

5.ZONE VALVES

6.MAINTENANCE

6.1.GENERAL REMARKS

6.2.CLEANING THE PRIMARY EXCHANGER

6.3.CLEANING THE CONDENSATE TRAP

6.4.OPERATIONAL TEST

7.TECHNICAL INFORMATION

1. GENERAL INFORMATION

This manual is an integral and essential part of the product. It should be kept with the appliance so that it can be consulted by the user and our authorised personnel.

Please carefully read the instructions and notices about the unit contained in this manual, as they provide important information regarding the safe installation, use and maintenance of the product.

For operating instructions please consult the separate User’s Manual.

1.1.GENERAL INFORMATION

Read the instructions and recommendations in these Installation Instructions carefully to ensure proper installation, use and maintenance of the appliance.

Keep this manual in a safe place. You may need it for your own reference while our Servicing Centre technicians or your installer may need to consult it in the future.

This is a combined appliance for the production of central heating (C.H.) and domestic hot water (D.H.W.).

This appliance must be used only for the purpose for which it is designed.

The manufacturer declines all liability for damage caused by improper or negligent use.

No asbestos or other hazardous materials have been used in the fabrication of this product.

Before connecting the appliance, check that the information shown on the data plate and the table on pages 4-5 comply with the electric, water and gas mains of the property. You will find the data plate on the reverse of the control panel.

The gas with which this appliance operates is also shown on the label at the bottom of the boiler.

Do not install this appliance in a damp environment or close to equipment which spray water or other liquids.

Do not place objects on the appliance.

Do not allow children or inexperienced persons to use the appliance without supervision.

If you smell gas in the room, do not turn on light switches, use the telephone or any other object which might cause sparks.

Open doors and windows immediately to ventilate the room.

Shut the gas mains tap (on the gas meter) or the valve of the gas cylinder and call your Gas Supplier immediately.

If you are going away for a long period of time, remember to shut the mains gas tap or the gas cylinder valve.

Always disconnect the appliance either by unplugging it from the mains or turning off the mains switch before cleaning the appliance or carrying out maintenance.

In the case of faults or failure, switch off the appliance and turn off the gas tap. Do not tamper with the appliance.

For repairs, call your local Authorised Servicing Centre and request the use of original spare parts. For in-guarantee repairs contact MTS (GB) Limited

2

275

Image 2
Contents Condensing Table of Contents General InformationReference Standards InstallationOverall View Siting the Appliance Overall DimensionsRffi System GAS Connection Mffi Mffi SystemMinimum Clearances Mounting the ApplianceMffi System Water ConnectionsFlue Connections Terminal PositionAccessory Connection Room Thermostat ConnectionConnections to the P.CB Under Floor Heating ConnectionElectrical Diagram JumperWater Circuit Diagrams C4 = TimerCommissioning Initial PreparationRemoving the Casing Control Panel Initial START-UPControl Modes Display Messages Shown During Normal OperationOperating Parameters Outdoor Sensor 275 Regulations Potentiometers Settings DisplaySetting the Temperature Field Comfort KEYRegulation Menu Table Boiler Safety SystemsPump Overrun Combustion Analysis DrainingGAS Adjustments Changing the Type of GAS Operating TestsCleaning the Condensate Trap Zone Valves MaintenanceCleaning the Primary Exchanger General RemarksOperational Test Technical Information Mffi Rffi SystemServicing Instructions Type C Boilers Fault Finding Replacement of Parts To Gain General Access Servicing InstructionsRemoving the sealed chamber front cover Access toRemoving the side panels Combustion ChamberRemoving the fan Removing the combustion chamber inspection panel Removing the burnerRemoving the electrodes Removing the condensate collector Removing the condensate trap Removing the injectorPage Access to the GAS Valve Removing the gas valveRemoving the D.H.W. secondary exchanger Removing the safety valveAccess to the Water Circuit Removing the automatic air vent Removing the main circuit flow switchRemoving the D.H.W. flow switch Removing the diverter valve actuatorRemoving the pump Removing the pressure gauge Removing the expansion vesselRemoving the C.H. flow temperature probe N.T.C Removing the D.H.W. temperature probe N.T.C. Mffi onlyRemoving the C.H. return temperature probe N.T.C Removing the time clock Access to the Control SystemChecking the fuses Removing the P.C.B.s Page FLOW-CHARTS Fault FindingFault Finding Guide Model 24 Rffi System Model 24 MFFI/24RFFI System Is the FAN Heating flow temperature probe in open circuit Electrical Diagrams JumperC5 = Remote Control Bus+/Bus C1 = FANEcoGENUS 24 Mffi ecoGENUS 24 Rffi Short Spare Parts List Ariston EcoGENUS 24 Rffi System EcoGENUS 24 Rffi System Technical Service Hot Line 01494 Ecogenus 24 Mffi Serial 24MFFIPart Code Description

47-116-17 specifications

The Ariston 47-116-17 is a blend of advanced technology and user-centric design, setting a new standard in home appliances. This washing machine stands out not only for its robust performance but also for its energy-efficient features, making it a top choice for environmentally conscious consumers.

One of the key features of the Ariston 47-116-17 is its impressive capacity. With a drum that can hold up to 7 kg of laundry, it accommodates a variety of household needs, from small loads to larger family washes. This ensures that users can complete their laundry tasks efficiently without multiple wash cycles.

The machine is equipped with a powerful motor that delivers effective cleaning while minimizing noise levels. This is especially beneficial for households where laundry is often done at night or during quiet hours. The appliance operates discreetly, allowing users to run cycles without disturbing the peace of the home environment.

Technology is at the forefront of the Ariston 47-116-17, featuring a comprehensive range of washing programs tailored to suit different fabric types and soil levels. The machine includes specialized settings for delicate fabrics, wool, and heavily soiled garments, ensuring that every item is treated with care. This versatility allows users to maintain the quality of their clothes while achieving optimal cleaning results.

Energy efficiency is another significant characteristic of the Ariston 47-116-17. It boasts a high energy rating, which translates to lower electricity bills and a reduced carbon footprint. The appliance also incorporates water-saving technology, which not only conserves water but also enhances overall efficiency during the wash cycle.

Additionally, the machine is designed with user convenience in mind. Its intuitive control panel makes it easy for users to select the desired programs and settings, even for those who may not be tech-savvy. The digital display provides clear information on remaining wash time, cycle status, and any error messages that may arise.

In conclusion, the Ariston 47-116-17 is a reliable, efficient, and user-friendly washing machine that meets the diverse needs of modern homes. Its combination of capacity, advanced cleaning technologies, energy efficiency, and convenience features makes it a noteworthy addition to any laundry room. Users can enjoy the benefits of powerful performance with the peace of mind that comes from choosing an environmentally responsible appliance.