Desa CGP18B Inspecting Burner, Burner Flame Pattern, Correct Flame Pattern AT High Position

Page 20

20

INSPECTING BURNER

Continued

If pilot flame pattern is incorrect, as shown in Figure 19

turn heater off (see To Turn Off Gas to Appliance, page 19)

see Troubleshooting, pages 21 through 24

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the heat shield height.

WARNING

If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, follow instructions at bottom of this page.

NOTICE

Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.

1/2 HEAT SHIELD OR GLASS HEIGHT

CORRECT FLAME PATTERN

AT HIGH POSITION

Figure 20 - Correct Burner Flame Pattern

Yellow

Tipping

1/2 HEAT SHIELD OR GLASS HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

Figure 21 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 21

turn heater off (see To Turn Off Gas to Appliance, page 19)

see Troubleshooting, pages 21 through 24

100098

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Information Product Identification Local CodesUnpacking ProductFresh AIR For CombustionVentilation Producing Adequate VentilationDetermining if You Have a Confined or Unconfined Space Fresh AIRDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Fresh AIR for Combustion and VentilationVentilation AIR Ventilation AIR Ventilation Air From OutdoorsInstalling To Wall Installation ItemsCheck GAS Type Locating Heater163/4 RP30B CGP18B CeilingFloor Installing Heater to Wall Mounting BracketRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting To GAS Qualified service person must connect heater to gas supplySupply Follow all local codesPressure Testing GAS Supply Piping System Checking GASConnections Servicing. Correct all leaks at oncePressure Testing Heater GAS Connections CheckingHeater What to do if YOU Smell GASOperating Heater PilotOperating InspectingBurner Pilot Flame PatternInspecting Burner Burner Flame PatternCorrect Flame Pattern AT High Position Incorrect Flame Pattern AT High PositionCleaning MaintenanceTrouble Shooting ODS/PILOT and BurnerTROUBLE- Shooting From Ing statement at TopRP30B CGP18B Technical ServiceService Hints Replacement Parts Parts Under WarrantyParts Not Under Warranty CentralsFloor Mounting Stand GA4000B AccessoriesManual Shutoff ODS/PILOT RP30B Parts List KEY Part Number Description QTY12-2 12-1 CGP18B Parts List Warranty Information Limited Warranty VENT-FREE Heaters