Desa installation manual Technical Service, Service Hints, RP30B CGP18B

Page 25

TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.

 

RP30B

CGP18B

BTU (Variable)

15,000/30,000

9,000/18,000

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (inches of water)

 

 

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

 

 

Heater

23.5 x 25.9 x 8.0

23.5 x 18.5 x 8.0

Carton

25.8 x 28.7 x 10.1

25.8 x 21.3 x 10.1

Weight (pounds)

 

 

Heater

30

22

Shipping

35

27

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane gas supply may be low

When gas quality is bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

100098

25

Image 25
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information ContentsSafety Information Local Codes Product IdentificationUnpacking ProductCombustion Fresh AIR ForVentilation Producing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Fresh AIRDetermining if You Have a Confined or Unconfined Space Ventilation AIR Fresh AIR for Combustion and VentilationVentilation Air From Inside Building Ventilation Air From Outdoors Ventilation AIRInstallation Items Installing To WallCheck GAS Type Locating HeaterFloor Ceiling163/4 RP30B CGP18B Mounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallAttaching Mounting Bracket To Wall Marking Screw LocationsPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsQualified service person must connect heater to gas supply Connecting To GASSupply Follow all local codesChecking GAS Pressure Testing GAS Supply Piping SystemConnections Servicing. Correct all leaks at onceChecking Pressure Testing Heater GAS ConnectionsWhat to do if YOU Smell GAS HeaterPilot Operating HeaterInspecting OperatingBurner Pilot Flame PatternBurner Flame Pattern Inspecting BurnerCorrect Flame Pattern AT High Position Incorrect Flame Pattern AT High PositionMaintenance CleaningTrouble Shooting ODS/PILOT and BurnerTROUBLE- Shooting From Top Ing statement atService Hints Technical ServiceRP30B CGP18B Parts Under Warranty Replacement PartsParts Not Under Warranty CentralsManual Shutoff AccessoriesFloor Mounting Stand GA4000B ODS/PILOT KEY Part Number Description QTY RP30B Parts List12-2 12-1 CGP18B Parts List Limited Warranty VENT-FREE Heaters Warranty Information