Desa CGP18B, RP30B installation manual Marking Screw Locations, Attaching Mounting Bracket To Wall

Page 12

12

INSTALLING TO WALL

Continued

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mount- ing bracket is level.

WARNING

Maintain minimum clearances shown in Figure 7. If you can, provide greater clearances from floor and joining wall.

2.Mark screw locations on wall (see Figure 7).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

11"

16"

7 1/4"

16"

Min.

 

Min.

 

AdjoiningWall

 

AdjoiningWall

Only Insert Mounting

 

Only Insert Mounting

32 1/2"

 

18 3/4"

Screws Through Last

Min.

 

Screws Through Last

Min.

Hole On Each End

 

 

Hole On Each End

 

Floor

 

 

 

Floor

 

 

 

 

 

 

 

 

RP30B

 

 

CGP18B

 

Figure 7 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater.

Attaching to wall stud method

For attaching mounting bracket to wall studs

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to wall anchor method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 8.

Figure 8 - Folding Anchor

3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

100098

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety InformationSafety Information Product Identification Local CodesUnpacking ProductFresh AIR For CombustionVentilation Producing Adequate VentilationFresh AIR Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Fresh AIR for Combustion and Ventilation Ventilation AIRVentilation Air From Inside Building Ventilation AIR Ventilation Air From OutdoorsInstalling To Wall Installation ItemsCheck GAS Type Locating HeaterCeiling Floor163/4 RP30B CGP18B Installing Heater to Wall Mounting BracketRemoving Front Panel Of Heater Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting To GAS Qualified service person must connect heater to gas supplySupply Follow all local codesPressure Testing GAS Supply Piping System Checking GASConnections Servicing. Correct all leaks at oncePressure Testing Heater GAS Connections CheckingHeater What to do if YOU Smell GASOperating Heater PilotOperating InspectingBurner Pilot Flame PatternInspecting Burner Burner Flame PatternCorrect Flame Pattern AT High Position Incorrect Flame Pattern AT High PositionCleaning MaintenanceTrouble Shooting ODS/PILOT and BurnerTROUBLE- Shooting From Ing statement at TopTechnical Service Service HintsRP30B CGP18B Replacement Parts Parts Under WarrantyParts Not Under Warranty CentralsAccessories Manual ShutoffFloor Mounting Stand GA4000B ODS/PILOT RP30B Parts List KEY Part Number Description QTY12-2 12-1 CGP18B Parts List Warranty Information Limited Warranty VENT-FREE Heaters